Literature DB >> 10882954

Magnetic imaging of colonoscopy: an audit of looping, accuracy and ancillary maneuvers.

S G Shah1, B P Saunders, J C Brooker, C B Williams.   

Abstract

BACKGROUND: Colonoscopy is one of the most frequently performed outpatient examinations. However, the procedure is still technically challenging, largely due to unpredictable looping during insertion. The aims of this study were (1) to assess the frequency of loop formation and types of loop during colonoscopy, (2) to determine the accuracy of the endoscopist's assessment of the anatomic location of the endoscope tip and of the presence and type of endoscope loop formation, and (3) to determine the efficacy of abdominal compression and change in patient position in promoting colonoscope advancement.
METHODS: Consecutive patients undergoing routine, day-case colonoscopy were studied using real-time, three-dimensional magnetic endoscope imaging. All examinations were performed by expert colonoscopists, blinded to the imager view. The endoscopist estimated the position of the colonoscope tip, assessed when and what type of loop had formed, and the efficacy of ancillary maneuvers such as hand pressure or patient position change. The magnetic imager view of each procedure was recorded and retrospectively analyzed.
RESULTS: One hundred complete colonoscopies were performed. Looping occurred in 91% with N-sigmoid (79%) and deep transverse (34%) being most common. Most loops (69%) were incorrectly diagnosed by the endoscopist. Atypical loops were more common in women than men (p = 0.025). The endoscopist's assessment of tip location was correct 85% of the time overall, but 100% in the cecum. Abdominal pressure was less effective (54 of 145 times, 37%) than patient position change (95 of 144 times, 66%) in promoting endoscope tip advancement.
CONCLUSIONS: Looping occurs frequently during routine colonoscopy. Although the endoscopist's assessment of tip location is fairly accurate, the majority of colonoscope loops are incorrectly appreciated. Although used frequently, ancillary maneuvers (abdominal compression and patient position change) are effective in only 52% of attempts.

Entities:  

Mesh:

Year:  2000        PMID: 10882954     DOI: 10.1067/mge.2000.107296

Source DB:  PubMed          Journal:  Gastrointest Endosc        ISSN: 0016-5107            Impact factor:   9.427


  32 in total

1.  Colorectal cancer incidence trends in the United States and United kingdom: evidence of right- to left-sided biological gradients with implications for screening.

Authors:  Rafael Meza; Jihyoun Jeon; Andrew G Renehan; E Georg Luebeck
Journal:  Cancer Res       Date:  2010-06-08       Impact factor: 12.701

2.  Determining scope position during colonoscopy without use of ionizing radiation or magnetic imaging: the enhanced mapping ability of the NeoGuide Endoscopy System.

Authors:  Johannes Striegel; Ralf Jakobs; Jacques Van Dam; Uwe Weickert; Jürgen F Riemann; Axel Eickhoff
Journal:  Surg Endosc       Date:  2010-08-21       Impact factor: 4.584

3.  Limited low-air insufflation is optimal for colonoscopy.

Authors:  Yu-Hsi Hsieh; Kuo-Chih Tseng; Hwai-Jeng Lin
Journal:  Dig Dis Sci       Date:  2010-04-22       Impact factor: 3.199

4.  Early use of magnetic endoscopic imaging by novice colonoscopists: improved performance without increase in workload.

Authors:  Sylvain Coderre; John Anderson; Remy Rikers; Paul Dunckley; Karen Holbrook; Kevin McLaughlin
Journal:  Can J Gastroenterol       Date:  2010-12       Impact factor: 3.522

Review 5.  Mechanical analysis of insertion problems and pain during colonoscopy: why highly skill-dependent colonoscopy routines are necessary in the first place... and how they may be avoided.

Authors:  Arjo J Loeve; Paul Fockens; Paul Breedveld
Journal:  Can J Gastroenterol       Date:  2013       Impact factor: 3.522

Review 6.  The impact of new technology on surgery for colorectal cancer.

Authors:  G B Makin; D J Breen; J R Monson
Journal:  World J Gastroenterol       Date:  2001-10       Impact factor: 5.742

7.  The use of ancillary techniques to aid colonoscope insertion.

Authors:  Xhileta Xhaja; James Church
Journal:  Surg Endosc       Date:  2014-02-25       Impact factor: 4.584

8.  Soft Robotics in Minimally Invasive Surgery.

Authors:  Mark Runciman; Ara Darzi; George P Mylonas
Journal:  Soft Robot       Date:  2019-03-28       Impact factor: 8.071

9.  Colorectal cancer anatomic distribution patterns remain the same after sessile serrated adenoma/polyp considered cancer precursor: a 9-year comparison study from community-based endoscopy centers.

Authors:  Juliana F Yang; Amy E Noffsinger; Deepak Agrawal; Qing-Hua Yang
Journal:  J Gastrointest Oncol       Date:  2016-12

10.  Robotics in Colonoscopy.

Authors:  Dan Cater; Arpita Vyas; Dinesh Vyas
Journal:  Am J Robot Surg       Date:  2014-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.