Anodic oxidation and hydrothermal treatment of titanium results in a surface that causes increased attachment and altered cytoskeletal morphology of rat bone marrow stromal cells in vitro.

J Takebe1, S Itoh, J Okada, K Ishibashi.   

Abstract

Previous studies have suggested the usefulness of a new coating method-namely, the forming of a thin hydroxyapatite (HA) layer on commercially pure titanium (cpTi) by anodization and hydrothermal treatment-for use as a dental root implant material. In vivo and in vitro studies confirmed that an HA layer on cpTi (HA/cpTi) implants showed good compatibility with bone tissue, rat bone marrow stromal (RBM) cells, and immune cells. The aim of the present investigation was to further characterize the in vitro early cellular behavior of RBM cells on HA/cpTi implants. Therefore, in this study we performed surface analysis, analysis of cell initial attachment, and analysis of cell morphology and the cytoskeleton. Drops of distilled water or cell culture medium showed smaller contact angles with HA/cpTi than with cpTi. RBM cells were cultured for 30, 60, and 120 min on HA/cpTi and cpTi, and the level of cell adhesion was shown to increase with time on both substrates. However, cell adhesion on HA/cpTi was significantly higher than on cpTi at 60 and 120 min. Especially at 120 min, when compared with cpTi, the cell morphology on the surface of HA/cpTi not only adopted a flattened and spreading form, but also extended filopodium-like processes with irregular edges that were intimately adapted to the surface of the HA microcrystals. The cytoskeleton on HA/cpTi showed well-formed actin filaments that were parallel to each other and the long axis of RBM cells. The actin filaments of RBM cells on the HA/cpTi surface were localized to the periphery (corresponding to the edge of the filopodium-like processes) well after 120 min. This suggests that actin filaments of RBM cells need to be anchored at the HA/cpTi surface and the numerous HA microcrystals precipitated on the HA/cpTi surface. These findings were similar to the scanning electron microscopic morphology. The peripheral anchorage provide sufficient strength of attachment to allow recognization of actin filaments upon HA/cpTi. The surface of HA/cpTi was more hydrophilic and exhibited markedly improved wettability compared to untreated cpTi, and higher levels of early cell attachment were observed on surfaces after anodization and hydrothermal treatment than on surfaces with untreated cpTi. The results of in vitro experiments suggest that this new method for forming a thin HA layer on the surface of cpTi could be useful to ensure excellent cellular behavior on implant surfaces. The characterization of cell morphology on the thin HA layer formed by anodization and hydrothermal treatment on cpTi implant material suggests that physicochemical or biological conditioning of the implant surface involves implant surface topography. Copyright 2000 John Wiley & Sons, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10880082     DOI: 10.1002/1097-4636(20000905)51:3<398::aid-jbm14>3.0.co;2-#

Source DB:  PubMed          Journal:  J Biomed Mater Res        ISSN: 0021-9304


  19 in total

Review 1.  Calcium Phosphate Bioceramics: A Review of Their History, Structure, Properties, Coating Technologies and Biomedical Applications.

Authors:  Noam Eliaz; Noah Metoki
Journal:  Materials (Basel)       Date:  2017-03-24       Impact factor: 3.623

2.  Nanopatterned bulk metallic glass-based biomaterials modulate macrophage polarization.

Authors:  Mahdis Shayan; Jagannath Padmanabhan; Aaron H Morris; Bettina Cheung; Ryan Smith; Jan Schroers; Themis R Kyriakides
Journal:  Acta Biomater       Date:  2018-06-01       Impact factor: 8.947

3.  Fabrication of strongly attached hydroxyapatite coating on titanium by hydrothermal treatment of Ti-Zn-PO4 coated titanium in CaCl 2 solution.

Authors:  Alireza Valanezhad; Kanji Tsuru; Kunio Ishikawa
Journal:  J Mater Sci Mater Med       Date:  2015-07-16       Impact factor: 3.896

4.  Functionalization of titanium based metallic biomaterials for implant applications.

Authors:  Rahul Bhola; Fengyun Su; Catherine E Krull
Journal:  J Mater Sci Mater Med       Date:  2011-04-08       Impact factor: 3.896

5.  Osseointegration improvement by plasma electrolytic oxidation of modified titanium alloys surfaces.

Authors:  Mónica Echeverry-Rendón; Oscar Galvis; David Quintero Giraldo; Juan Pavón; José Luis López-Lacomba; Emilio Jiménez-Piqué; Marc Anglada; Sara M Robledo; Juan G Castaño; Félix Echeverría
Journal:  J Mater Sci Mater Med       Date:  2015-01-29       Impact factor: 3.896

Review 6.  Implants in bone: part I. A current overview about tissue response, surface modifications and future perspectives.

Authors:  Cornelius von Wilmowsky; Tobias Moest; Emeka Nkenke; Florian Stelzle; Karl Andreas Schlegel
Journal:  Oral Maxillofac Surg       Date:  2013-02-24

7.  Electrodeposition of nanostructured bioactive hydroxyapatite-heparin composite coatings on titanium for dental implant applications.

Authors:  Benedetto Bozzini; Amilcare Barca; Francesco Bogani; Marco Boniardi; Paolo Carlino; Claudio Mele; Tiziano Verri; Alessandro Romano
Journal:  J Mater Sci Mater Med       Date:  2014-03-12       Impact factor: 3.896

8.  Interfacial adhesion and surface bioactivity of anodized titanium modified with SiON and SiONP surface coatings.

Authors:  Kamal Awad; Simon Young; Pranesh Aswath; Venu Varanasi
Journal:  Surf Interfaces       Date:  2021-11-28

9.  Hydroxyapatite/NELL-1 Nanoparticles Electrospun Fibers for Osteoinduction in Bone Tissue Engineering Application.

Authors:  Hualei Song; Yuntao Zhang; Zihan Zhang; Shijiang Xiong; Xiangrui Ma; Yourui Li
Journal:  Int J Nanomedicine       Date:  2021-06-25

10.  Osteogenic activity of titanium surfaces with nanonetwork structures.

Authors:  Helin Xing; Satoshi Komasa; Yoichiro Taguchi; Tohru Sekino; Joji Okazaki
Journal:  Int J Nanomedicine       Date:  2014-04-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.