Effects of nonius line and fusion lock parameters on fixation disparity.

M T Ukwade1.   

Abstract

PURPOSE: Clinical devices for fixation disparity vary in the size and position of the nonius test-lines and in the location of the binocular fusion lock, and published results of studies comparing fixation disparity devices also vary. This study examined how varying stimulus parameters affects the magnitude of horizontal fixation disparity and the precision of nonius alignment in normal observers.
METHODS: Targets were bright vertical lines presented for 150 ms on an oscilloscope and viewed in the dark from 3.95 m through a mirror haploscope. The fusion stimulus was either central, peripheral, or central-plus-peripheral. Fixation disparity was measured for nonius lines with a fixed vertical separation and variable lengths, using the method of constant stimuli. In a second experiment, fixation disparity was assessed for vergence demands of 6delta base-in to 12delta base-out using nonius lines of fixed length and variable vertical separations. For comparison, binocular Vernier thresholds and constant errors were also assessed.
RESULTS: Mean values of fixation disparity are invariant with the length and separation of the nonius lines and proximity to the fusion lock, over the range of values tested. When measured with a central fusion lock, the precision of binocular nonius alignment (vergence variability) worsens if the separation between the nonius lines increases beyond approximately 20 min arc. Vergence variability is larger with a peripheral fusion lock for small nonius-line separations and approximately the same as with the central lock for large line separations. Fixation disparity and precision were smallest with a central-plus-peripheral fusion-lock combination. Similar effects of line length and separation were found for binocular Vernier.
CONCLUSIONS: The finding of invariance of fixation disparity with line length for nonius targets < 1degrees extends those of earlier findings for larger targets. Because the precision of binocular nonius alignment is poorer for large nonius-line separations or with a peripheral fusion lock, fixation disparity should be most repeatable when measured with a central fusion lock and nonius lines separated by 20 min arc or less. However, a peripheral fusion lock and small nonius-line separation may provide the most effective diagnostic combination for fixation disparity.

Entities:  

Mesh:

Year:  2000        PMID: 10879788     DOI: 10.1097/00006324-200006000-00011

Source DB:  PubMed          Journal:  Optom Vis Sci        ISSN: 1040-5488            Impact factor:   1.973


  7 in total

1.  Binocular combination of phase and contrast explained by a gain-control and gain-enhancement model.

Authors:  Jian Ding; Stanley A Klein; Dennis M Levi
Journal:  J Vis       Date:  2013-02-08       Impact factor: 2.240

2.  A unified model for binocular fusion and depth perception.

Authors:  Jian Ding; Dennis M Levi
Journal:  Vision Res       Date:  2020-12-21       Impact factor: 1.886

3.  Effects of Prism Eyeglasses on Objective and Subjective Fixation Disparity.

Authors:  Volkhard Schroth; Roland Joos; Wolfgang Jaschinski
Journal:  PLoS One       Date:  2015-10-02       Impact factor: 3.240

4.  Individual Objective and Subjective Fixation Disparity in Near Vision.

Authors:  Wolfgang Jaschinski
Journal:  PLoS One       Date:  2017-01-30       Impact factor: 3.240

5.  Is the aligning prism measured with the Mallett unit correlated with fusional vergence reserves?

Authors:  Miriam L Conway; Jennifer Thomas; Ahalya Subramanian
Journal:  PLoS One       Date:  2012-08-08       Impact factor: 3.240

Review 6.  Binocular fusion, suppression and diplopia for blurred edges.

Authors:  Mark A Georgeson; Stuart A Wallis
Journal:  Ophthalmic Physiol Opt       Date:  2014-01-29       Impact factor: 3.117

7.  Does an iPad fixation disparity test give equivalent results to the Mallett near fixation disparity test?

Authors:  Ketan R Parmar; Christine Dickinson; Bruce J W Evans
Journal:  J Optom       Date:  2019-09-07
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.