Literature DB >> 10859102

The reliability and validity of the self-reported patient-specific index for total hip arthroplasty.

J G Wright1, N L Young, J P Waddell.   

Abstract

BACKGROUND: The Patient-Specific Index is unique in that it reflects how individual patients weigh concerns in rating the outcome of total hip arthroplasty. The Patient-Specific Index was originally administered by an interviewer, which is not always feasible and can be costly. The purposes of the present study were (1) to create a self-reported version of the Patient-Specific Index, (2) to determine the reliability of this new self-reported version, and (3) to determine the relationship between the scores on the new self-reported version and those on the original interviewer-administered version.
METHODS: A self-reported version of the Patient-Specific Index was developed, and a pilot test was performed on ten patients. Patients who were scheduled for a total hip arthroplasty or who had recently had a total hip arthroplasty were eligible for the reliability and validity testing. A copy of the new self-reported Patient-Specific Index was mailed to the patients, and they completed it independently. The patients' ratings of the importance and severity of twenty-four concerns prior to total hip arthroplasty were added together to create a summary Patient-Specific Index score. To determine test-retest reliability, patients completed the self-reported Patient-Specific Index a second time, two weeks later. To determine criterion validity, participants also completed the interviewer-administered Patient-Specific Index.
RESULTS: Fifty-five patients completed the study. The random-effects intraclass correlation test-retest coefficient was 0.79 (greater than 0.75 represents excellent reliability). The mean Patient-Specific Index scores on the self-reported version and on the interviewer-administered version were 173 and 165 points, respectively (Student t test, p = 0.45). The self-reported Patient-Specific Index was concordant with the interviewer-administered Patient-Specific Index (intraclass correlation coefficient, 0.78).
CONCLUSIONS: We concluded that a self-reported version of the Patient-Specific Index, which focuses on the concerns of individuals, is reliable and has criterion validity compared with an interviewer-administered version.

Entities:  

Mesh:

Year:  2000        PMID: 10859102     DOI: 10.2106/00004623-200006000-00009

Source DB:  PubMed          Journal:  J Bone Joint Surg Am        ISSN: 0021-9355            Impact factor:   5.284


  9 in total

Review 1.  Cultural Biases in Current Medical Practices with a Specific Attention to Orthopedic Surgery: a Review.

Authors:  Gracia Etienne; Todd P Pierce; Anton Khlopas; Morad Chughtai; Carlos J Lavernia; Teva Y Vogelstein; Craig M Thomas; Charles S Modlin; Michael A Mont
Journal:  J Racial Ethn Health Disparities       Date:  2017-07-17

2.  Evidence-Based Surgery. Users' guide to the surgical literature: how to assess an article on health-related quality of life.

Authors:  Achilleas Thoma; Sylvie D Cornacchi; Peter J Lovrics; Charlie H Goldsmith
Journal:  Can J Surg       Date:  2008-06       Impact factor: 2.089

3.  Hard-on-Hard Bearings Are Associated With Increased Noise Generation in Young Patients Undergoing Hip Arthroplasty.

Authors:  Denis Nam; Toby Barrack; Staci R Johnson; Ryan M Nunley; Robert L Barrack
Journal:  Clin Orthop Relat Res       Date:  2016-10       Impact factor: 4.176

4.  Modular cementless cup for total hip arthroplasty: results at 4-year follow-up.

Authors:  Alessandro Bistolfi; Giuseppe Massazza; Federica Rosso; Stefano Ventura; Francesco Lagalla; Maurizio Crova
Journal:  Musculoskelet Surg       Date:  2012-01-06

5.  Do young, active patients perceive advantages after surface replacement compared to cementless total hip arthroplasty?

Authors:  Robert L Barrack; Erin L Ruh; Michael E Berend; Craig J Della Valle; C Anderson Engh; Javad Parvizi; John C Clohisy; Ryan M Nunley
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

6.  Quality of life after TKA for patients with juvenile rheumatoid arthritis.

Authors:  Brigitte M Jolles; Earl R Bogoch
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

7.  Comparison of patient and surgeon expectations of total hip arthroplasty.

Authors:  Claire Jourdan; Serge Poiraudeau; Stéphane Descamps; Rémy Nizard; Moussa Hamadouche; Philippe Anract; Stéphane Boisgard; Myriam Galvin; Philippe Ravaud
Journal:  PLoS One       Date:  2012-01-17       Impact factor: 3.240

8.  Characterizing the Use of Expectations in Orthopedic Surgery Research: A Scoping Review.

Authors:  Alejandro Cortes; Samantha M Meints; Jeffrey N Katz
Journal:  ACR Open Rheumatol       Date:  2019-08-08

9.  The role of patient expectations in predicting outcome after total knee arthroplasty.

Authors:  Anne F Mannion; Stephane Kämpfen; Urs Munzinger; Ines Kramers-de Quervain
Journal:  Arthritis Res Ther       Date:  2009-09-21       Impact factor: 5.156

  9 in total