Literature DB >> 23091670

Posterior atalntoaxial fusion with c1 lateral mass screw and c2 pedicle screw supplemented with miniplate fixation for interlaminar fusion : a preliminary report.

Sang-Mok Yoon1, Jin-Wook Baek, Dae-Hyun Kim.   

Abstract

OBJECTIVE: To investigate the feasibility of C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion to treat various atlantoaxial instabilities.
METHODS: After posterior atlantoaxial fixation with lateral mass screw in the atlas and pedicle screw in the axis, we used 2 miniplates to fixate interlaminar iliac bone graft instead of sublaminar wiring. We performed this procedure in thirteen patients who had atlantoaxial instabilities and retrospectively evaluated the bone fusion rate and complications.
RESULTS: By using this method, we have achieved excellent bone fusion comparing with the result of other methods without any complications related to this procedure.
CONCLUSION: C1 lateral mass screw and C2 pedicle screw with polyaxial screw and rod system supplemented with miniplate for interlaminar fusion may be an efficient alternative method to treat various atlantoaxial instabilities.

Entities:  

Keywords:  Atalantoaxial stabilization; Cervical spine; Interlaminar fusion

Year:  2012        PMID: 23091670      PMCID: PMC3467369          DOI: 10.3340/jkns.2012.52.2.120

Source DB:  PubMed          Journal:  J Korean Neurosurg Soc        ISSN: 1225-8245


  31 in total

Review 1.  Innovative cervical fusion and instrumentation techniques.

Authors:  V K Sonntag; I Kalfas
Journal:  Clin Neurosurg       Date:  1991

Review 2.  Biomechanics of cervical spine internal fixation.

Authors:  P X Montesano; E C Juach; P A Anderson; D R Benson; P B Hanson
Journal:  Spine (Phila Pa 1976)       Date:  1991-03       Impact factor: 3.468

3.  Biomechanical evaluation of four different posterior atlantoaxial fixation techniques.

Authors:  D Grob; J J Crisco; M M Panjabi; P Wang; J Dvorak
Journal:  Spine (Phila Pa 1976)       Date:  1992-05       Impact factor: 3.468

4.  Anatomic and biomechanical assessment of transarticular screw fixation for atlantoaxial instability.

Authors:  P B Hanson; P X Montesano; N A Sharkey; W Rauschning
Journal:  Spine (Phila Pa 1976)       Date:  1991-10       Impact factor: 3.468

Review 5.  The status of arthrodesis of the cervical spine.

Authors:  J W Fielding
Journal:  J Bone Joint Surg Am       Date:  1988-12       Impact factor: 5.284

6.  Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws.

Authors:  I M Mandel; B J Kambach; C A Petersilge; B Johnstone; J U Yoo
Journal:  Spine (Phila Pa 1976)       Date:  2000-06-15       Impact factor: 3.468

7.  Atlantoaxial transarticular screw fixation: a review of surgical indications, fusion rate, complications, and lessons learned in 191 adult patients.

Authors:  Wayne M Gluf; Meic H Schmidt; Ronald I Apfelbaum
Journal:  J Neurosurg Spine       Date:  2005-02

8.  Atlantoaxial stabilization with the use of C1-3 lateral mass screw fixation. Technical note.

Authors:  Eric M Horn; Jonathan S Hott; Randall W Porter; Nicholas Theodore; Stephen M Papadopoulos; Volker K H Sonntag
Journal:  J Neurosurg Spine       Date:  2006-08

9.  C1-C2 transarticular screw fixation for atlantoaxial instability: a 6-year experience.

Authors:  R W Haid; B R Subach; M R McLaughlin; G E Rodts; J B Wahlig
Journal:  Neurosurgery       Date:  2001-07       Impact factor: 4.654

10.  Arthrodesis of the cervical spine in rheumatoid arthritis.

Authors:  C R Clark; D D Goetz; A H Menezes
Journal:  J Bone Joint Surg Am       Date:  1989-03       Impact factor: 5.284

View more
  3 in total

1.  The height for screw index (HSI) predicts the development of C2 nerve dysfunction associated with C1 lateral mass screw fixation for atlantoaxial instability.

Authors:  Da-Geng Huang; Ding-Jun Hao; Yong-Hong Jiang; Yue Cheng; Jun-Wei Pan; Yong-Qian Qiang; Bao-Rong He; Li-Xiong Qian
Journal:  Eur Spine J       Date:  2014-02-26       Impact factor: 3.134

2.  The Intersection Between Lateral Mass and Inferomedial Edge of the C1 Posterior Arch: A Reference Point for C1 Lateral Mass Screw Insertion.

Authors:  Torphong Bunmaprasert; Watcharapong Puangkaew; Nantawit Sugandhavesa; Wongthawat Liawrungrueang; K Daniel Riew
Journal:  Neurospine       Date:  2021-06-30

3.  Repeated complication following atlantoaxial fusion: a case report.

Authors:  Chang Hyun Oh; Gyu Yeul Ji; Hyun Sung Seo; Seung Hwan Yoon; Dongkeun Hyun; Hyeong-Chun Park
Journal:  Korean J Spine       Date:  2014-03-31
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.