Fluid dynamics of a pediatric ventricular assist device.

C Bachmann1, G Hugo, G Rosenberg, S Deutsch, A Fontaine, J M Tarbell.   

Abstract

The number of pediatric patients requiring some form of mechanical circulatory assistance is growing throughout the world because of new surgical procedures and the success of pediatric cardiac transplantation. However, the salvage rate for those patients requiring circulatory support may be as low as 25%. Despite the fact that Penn State's 70 cc pneumatic ventricular assist device has been used with a success rate of over 90% in more than 250 patients worldwide, efforts to scale down the pump have encountered difficulties. Animal experiments with a 15 cc version were unsuccessful, with explanted pumps showing extensive thrombus deposition within the pumping chamber. The materials used to fabricate the smaller pump as well as the basic operating principles are identical to the successful adult-sized version. It is therefore believed that reducing the size of the pump altered the internal flow field, and that fluid dynamic factors were responsible for the high degree of thrombus observed with the implanted devices. A dimensional analysis was conducted that revealed significant differences in both Reynolds (Re) and Strouhal (St) numbers between the successful and unsuccessful pumps. Two component laser Doppler velocimetry was then used to characterize the internal flow field quantitatively. Comparison with data from the 70 cc pump showed a reduction in wall shear stress and turbulence levels in the 15 cc pump that would yield an environment conducive to clot formation.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10848677     DOI: 10.1046/j.1525-1594.2000.06536.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  9 in total

1.  Experimental Investigation of the Effect of Non-Newtonian Behavior of Blood Flow in the Fontan Circulation.

Authors:  Andrew L Cheng; Niema M Pahlevan; Derek G Rinderknecht; John C Wood; Morteza Gharib
Journal:  Eur J Mech B Fluids       Date:  2017-12-27       Impact factor: 2.183

2.  Hemodynamics in a Pediatric Ascending Aorta Using a Viscoelastic Pediatric Blood Model.

Authors:  Bryan C Good; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2015-07-10       Impact factor: 3.934

3.  Validation of a CFD methodology for positive displacement LVAD analysis using PIV data.

Authors:  Richard B Medvitz; Varun Reddy; Steve Deutsch; Keefe B Manning; Eric G Paterson
Journal:  J Biomech Eng       Date:  2009-11       Impact factor: 2.097

4.  Toward the Virtual Benchmarking of Pneumatic Ventricular Assist Devices: Application of a Novel Fluid-Structure Interaction-Based Strategy to the Penn State 12 cc Device.

Authors:  Alessandro Caimi; Francesco Sturla; Bryan Good; Marco Vidotto; Rachele De Ponti; Filippo Piatti; Keefe B Manning; Alberto Redaelli
Journal:  J Biomech Eng       Date:  2017-08-01       Impact factor: 2.097

Review 5.  Towards non-thrombogenic performance of blood recirculating devices.

Authors:  D Bluestein; K B Chandran; K B Manning
Journal:  Ann Biomed Eng       Date:  2010-02-04       Impact factor: 3.934

6.  Flow visualization of three-dimensionality inside the 12 cc Penn State pulsatile pediatric ventricular assist device.

Authors:  Breigh N Roszelle; Steven Deutsch; Keefe B Manning
Journal:  Ann Biomed Eng       Date:  2010-02       Impact factor: 3.934

7.  The influence of device position on the flow within the Penn State 12 cc pediatric ventricular assist device.

Authors:  Markus Schönberger; Steven Deutsch; Keefe B Manning
Journal:  ASAIO J       Date:  2012 Sep-Oct       Impact factor: 2.872

8.  Assessment of hydraulic performance and biocompatibility of a MagLev centrifugal pump system designed for pediatric cardiac or cardiopulmonary support.

Authors:  Kurt A Dasse; Barry Gellman; Marina V Kameneva; Joshua R Woolley; Carl A Johnson; Thomas Gempp; John D Marks; Stella Kent; Andrew Koert; J Scott Richardson; Steve Franklin; Trevor A Snyder; Peter Wearden; William R Wagner; Richard J Gilbert; Harvey S Borovetz
Journal:  ASAIO J       Date:  2007 Nov-Dec       Impact factor: 2.872

9.  A 4D flow MRI evaluation of the impact of shear-dependent fluid viscosity on in vitro Fontan circulation flow.

Authors:  Andrew L Cheng; Choo Phei Wee; Niema M Pahlevan; John C Wood
Journal:  Am J Physiol Heart Circ Physiol       Date:  2019-10-04       Impact factor: 4.733