Literature DB >> 10845402

A contaminated binormal model for ROC data: Part II. A formal model.

D D Dorfman1, K S Berbaum.   

Abstract

RATIONALE AND
OBJECTIVES: A contaminated binormal receiver operating characteristic (ROC) model is proposed to account for ROC data that have very few false-positive reports even though many healthy subjects are sampled. The model assumes that no signal information is captured for a proportion of abnormalities, and that these abnormalities have the same distribution as noise along the latent decision axis.
MATERIALS AND METHODS: The authors developed a formal psychophysical model, presented here in detail. They have specified the psychophysical assumptions of the theory, and have provided proofs that include all essential details, from assumptions to implications. With the technical details that are provided, this theory can be implemented with computer programs to fit data.
RESULTS: The new model can fit ROC data in which some or all of the ROC points have false-positive fractions of 0 and true-positive fractions of less than 1, without implying that performance is perfect. The resulting ROC curves are always proper, never exhibiting inappropriate chance line crossings. The model predicts that, under certain conditions, a bimodal categorical rating histogram will be observed for the signal distribution. The model predicts a relationship between the mean and standard deviation of the signal distribution and holds that, for expert decision makers, there are situations in which the prevalence and utility matrix preclude operating points in some ROC regions. The model has a straightforward extension to the joint detection and localization ROC curve.
CONCLUSION: The contaminated binormal model accounts for ROC data with few or no false-positive reports.

Mesh:

Year:  2000        PMID: 10845402     DOI: 10.1016/s1076-6332(00)80383-9

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  24 in total

1.  Comparison of semiparametric receiver operating characteristic models on observer data.

Authors:  Frank W Samuelson; Xin He
Journal:  J Med Imaging (Bellingham)       Date:  2014-08-28

2.  A search model and figure of merit for observer data acquired according to the free-response paradigm.

Authors:  D P Chakraborty
Journal:  Phys Med Biol       Date:  2006-07-06       Impact factor: 3.609

3.  ROC curves predicted by a model of visual search.

Authors:  D P Chakraborty
Journal:  Phys Med Biol       Date:  2006-07-06       Impact factor: 3.609

4.  Does computer-aided diagnosis for lung tumors change satisfaction of search in chest radiography?

Authors:  Kevin S Berbaum; Robert T Caldwell; Kevin M Schartz; Brad H Thompson; E A Franken
Journal:  Acad Radiol       Date:  2007-09       Impact factor: 3.173

5.  Evaluation of computer-aided detection and diagnosis systems.

Authors:  Nicholas Petrick; Berkman Sahiner; Samuel G Armato; Alberto Bert; Loredana Correale; Silvia Delsanto; Matthew T Freedman; David Fryd; David Gur; Lubomir Hadjiiski; Zhimin Huo; Yulei Jiang; Lia Morra; Sophie Paquerault; Vikas Raykar; Frank Samuelson; Ronald M Summers; Georgia Tourassi; Hiroyuki Yoshida; Bin Zheng; Chuan Zhou; Heang-Ping Chan
Journal:  Med Phys       Date:  2013-08       Impact factor: 4.071

6.  Digital breast tomosynthesis versus digital mammography: a clinical performance study.

Authors:  Gisella Gennaro; Alicia Toledano; Cosimo di Maggio; Enrica Baldan; Elisabetta Bezzon; Manuela La Grassa; Luigi Pescarini; Ilaria Polico; Alessandro Proietti; Aida Toffoli; Pier Carlo Muzzio
Journal:  Eur Radiol       Date:  2009-12-22       Impact factor: 5.315

7.  Performance evaluation of radiologists with artificial neural network for differential diagnosis of intra-axial cerebral tumors on MR images.

Authors:  K Yamashita; T Yoshiura; H Arimura; F Mihara; T Noguchi; A Hiwatashi; O Togao; Y Yamashita; T Shono; S Kumazawa; Y Higashida; H Honda
Journal:  AJNR Am J Neuroradiol       Date:  2008-04-03       Impact factor: 3.825

8.  Comparison between differently priced devices for digital capture of X-ray films using computed tomography as a gold standard: a multireader-multicase receiver operating characteristic curve study.

Authors:  Antonio J Salazar; Juan Camilo Camacho; Diego Andrés Aguirre
Journal:  Telemed J E Health       Date:  2011-04-01       Impact factor: 3.536

9.  Generalized Roe and Metz receiver operating characteristic model: analytic link between simulated decision scores and empirical AUC variances and covariances.

Authors:  Brandon D Gallas; Stephen L Hillis
Journal:  J Med Imaging (Bellingham)       Date:  2014-09-25

10.  Operating characteristics predicted by models for diagnostic tasks involving lesion localization.

Authors:  D P Chakraborty; Hong-Jun Yoon
Journal:  Med Phys       Date:  2008-02       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.