Literature DB >> 10843127

The influence of screw geometry on hamstring tendon interference fit fixation.

A Weiler1, R F Hoffmann, C J Siepe, S F Kolbeck, N P Südkamp.   

Abstract

We used a standardized model of calf tibial bone to investigate the influence of screw diameter and length on interference fit fixation of a three-stranded semitendinosus tendon graft for anterior cruciate ligament reconstruction. Biodegradable poly-(L-lactide) interference screws with a diameter of 7, 8, and 9 mm and a length of 23 and 28 mm were used. We examined results in three groups of 10 specimens each: group 1, screw diameter equaled graft diameter and screw length was 23 mm; group 2, screw diameter equaled graft diameter plus 1 mm and screw length was 23 mm; group 3, screw diameter equaled graft diameter and screw length was 28 mm. The mean pull-out forces in groups 1, 2, and 3 were 367.2+/-78 N, 479.1+/-111.1 N, and 537.4+/-139.1 N, respectively. The force data from groups 2 and 3 were significantly higher than those from group 1. These results indicate that screw geometry has a significant influence on hamstring tendon interference fit fixation. Increasing screw length improves fixation strength more than oversizing the screw diameter. This is important, especially for increasing tibial fixation strength because the tibial graft fixation site has been considered to be the weak link of such a reconstruction.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10843127     DOI: 10.1177/03635465000280031201

Source DB:  PubMed          Journal:  Am J Sports Med        ISSN: 0363-5465            Impact factor:   6.202


  21 in total

1.  Optimal screw diameter for interference fixation in a bone tunnel: a porcine model.

Authors:  M W J Morris; J L Williams; A J Thake; Y Lang; J N Brown
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-02-06       Impact factor: 4.342

2.  Initial fixation strength of interference nail fixation for anterior cruciate ligament reconstruction with patellar tendon graft (experimental study).

Authors:  H Aydin; S Kerimoğlu; A Citlak; A U Turhan
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2003-07-31       Impact factor: 4.342

3.  Interference screws should be shorter than the hamstring tendon graft in the bone tunnel for best fixation.

Authors:  Michael Stalder; Mazda Farshad; Jess G Snedeker; Dominik C Meyer
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2012-03-21       Impact factor: 4.342

4.  [Biomechanical analysis of press-fit fixation of anterior cruciate ligament transplants].

Authors:  M Jagodzinski; M Ettinger; C Haasper; S Hankemeier; D Breitmeier; C Hurschler; C Krettek
Journal:  Unfallchirurg       Date:  2010-07       Impact factor: 1.000

5.  Tibial press-fit fixation of the hamstring tendons for ACL-reconstruction.

Authors:  M Jagodzinski; K Scheunemann; K Knobloch; K Albrecht; C Krettek; C Hurschler; J Zeichen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-06-09       Impact factor: 4.342

6.  Initial fixation strength of a hybrid technique for femoral ACL graft fixation.

Authors:  Andre Weimann; Thore Zantop; Mirco Herbort; Michael Strobel; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-08-24       Impact factor: 4.342

7.  Bioabsorbable screw divergence angle, not tunnel preparation method influences soft tissue tendon graft-bone tunnel fixation in healthy bone.

Authors:  Andrew R Duffee; Jeffrey A Brunelli; John Nyland; Robert Burden; Akbar Nawab; David Caborn
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2006-09-09       Impact factor: 4.342

8.  Biomechanical properties of femoral posterior cruciate ligament fixations.

Authors:  M Ettinger; M Petri; K T Haag; S Brand; A Dratzidis; C Hurschler; C Krettek; M Jagodzinski
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2013-07-03       Impact factor: 4.342

Review 9.  Graft fixation alternatives in anterior cruciate ligament reconstruction.

Authors:  Bernardino Saccomanni
Journal:  Musculoskelet Surg       Date:  2011-05-03

10.  Influence of hydroxyapatite-coated and growth factor-releasing interference screws on tendon-bone healing in an ovine model.

Authors:  Yan Lu; Mark D Markel; Brett Nemke; J Sam Lee; Ben K Graf; William L Murphy
Journal:  Arthroscopy       Date:  2009-11-06       Impact factor: 4.772

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.