Dosimetric characteristics of the InterSource103 palladium brachytherapy source.

A S Meigooni1, K Sowards, M Soldano.   

Abstract

103Pd brachytherapy sources are being used for interstitial implants in tumor sites such as the prostate. Recently, the InterSource103 palladium source has been introduced, which has a design different from that of other sources presently on the market. Dosimetric characteristics (i.e., dose rate constant, radial dose function, and anisotropy function) of this source were experimentally and theoretically determined following the AAPM Task Group 43 (TG-43) recommendations and were related to the 1999 NIST calibration assigned to this source [Sk, 99std]. Measurements were performed in a solid water phantom using LiF thermoluminescent dosimeters. The measured data was compared with Monte Carlo simulations performed in solid water using the PTRAN code. The calculations were then performed in liquid water to obtain the dosimetric information for clinical applications as per TG-43 recommendation. The results indicated that the dose rate constant, lambda, of the InterSource103 palladium source was 0.664+/-5% cGy/h/U using TLD measurements and 0.660+/-3% cGy/h/U using Monte Carlo simulations in solid water. The calculated value in liquid water was found to be 0.696 +/- 3 % cGy/h/U. The radial dose function, g(r), of the new 103Pd source was measured at distances ranging from 0.5 to 10 cm using LiF TLD in solid water phantom material. The Monte Carlo simulations were performed at distances ranging from 0.1 to 10 cm from the source center in solid water and liquid water. The anisotropy function, F(r, theta), was measured at distances of 2, 3, 5, and 7 cm from the source center and calculated at distances of 0.5, 1, 2, 3, 5, and 7 cm from the source center. Complete dosimetric data are described in this paper. Per TG-43, the values reported in water should be used for clinical treatment planning systems.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10841414     DOI: 10.1118/1.598991

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  4 in total

1.  Dosimetric characterization and output verification for conical brachytherapy surface applicators. Part I. Electronic brachytherapy source.

Authors:  Regina K Fulkerson; John A Micka; Larry A DeWerd
Journal:  Med Phys       Date:  2014-02       Impact factor: 4.071

2.  Thermoluminescent and Monte Carlo dosimetry of IR06-103Pd brachytherapy source.

Authors:  Pooneh Saidi; Mahdi Sadeghi; S Hamed Hosseini; Claudio Tenreiro
Journal:  J Appl Clin Med Phys       Date:  2011-11-15       Impact factor: 2.102

3.  Impact of the vaginal applicator and dummy pellets on the dosimetry parameters of Cs-137 brachytherapy source.

Authors:  Sedigheh Sina; Reza Faghihi; Ali S Meigooni; Simin Mehdizadeh; M Amin Mosleh Shirazi; Mehdi Zehtabian
Journal:  J Appl Clin Med Phys       Date:  2011-05-19       Impact factor: 2.243

4.  Cylindrical coordinate based TG-43U1 parameters for dose calculation around elongated brachytherapy sources.

Authors:  Shahid B Awan; Sharifeh A Dini; Manzoor Hussain; David Soleimani-Meigooni; Ali S Meigooni
Journal:  J Appl Clin Med Phys       Date:  2008-04-16       Impact factor: 2.102

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.