H J Zar1, E G Weinberg, H J Binns, F Gallie, M D Mann. 1. Department of Paediatrics and Child Health, Red Cross War Memorial Children's Hospital, University of Cape Town, Cape Town, South Africa. heather@rmh.uct.ac.za
Abstract
AIMS: To investigate (1) aerosol lung deposition obtained from two small volume conventional spacers (Babyhaler and Aerochamber) and a home made spacer (modified 500 ml plastic cold drink bottle); (2) the effect of using a face mask or mouthpiece; and (3) the relation between age and pulmonary deposition. METHODS:Lung deposition of aerosolised technetium-99m DTPA inhaled via spacer was measured in 40 children aged 3-7 years with stable asthma. Each patient performed sequential randomly assigned inhalations using two spacers. Three studies were performed: Babyhaler compared to Aerochamber (with facemasks); Babyhaler with facemask compared to Babyhaler with mouthpiece; and Babyhaler with mouthpiece compared to a 500 ml bottle. RESULTS:Median lung aerosol deposition from a Babyhaler and Aerochamber with masks were similar (25% v 21%, p = 0.9). Aerosol lung deposition from a Babyhaler with mask compared to a Babyhaler with mouthpiece was equivalent (26% v 26%, p = 0.5). Lung deposition was higher from a 500 ml bottle compared to a Babyhaler in both young (25% v 12.5%, p = 0.005) and older children (42% v 22.5%, p = 0.003). A notable reduction in pulmonary deposition occurred at 50 months of age. CONCLUSION: A Babyhaler or Aerochamber produce equivalent lung deposition of aerosol. There is no difference in lung deposition when a mask or mouthpiece is used. A modified 500 ml plastic bottle produces greater pulmonary aerosol deposition than a conventional small volume spacer.
RCT Entities:
AIMS: To investigate (1) aerosol lung deposition obtained from two small volume conventional spacers (Babyhaler and Aerochamber) and a home made spacer (modified 500 ml plastic cold drink bottle); (2) the effect of using a face mask or mouthpiece; and (3) the relation between age and pulmonary deposition. METHODS: Lung deposition of aerosolised technetium-99m DTPA inhaled via spacer was measured in 40 children aged 3-7 years with stable asthma. Each patient performed sequential randomly assigned inhalations using two spacers. Three studies were performed: Babyhaler compared to Aerochamber (with facemasks); Babyhaler with facemask compared to Babyhaler with mouthpiece; and Babyhaler with mouthpiece compared to a 500 ml bottle. RESULTS: Median lung aerosol deposition from a Babyhaler and Aerochamber with masks were similar (25% v 21%, p = 0.9). Aerosol lung deposition from a Babyhaler with mask compared to a Babyhaler with mouthpiece was equivalent (26% v 26%, p = 0.5). Lung deposition was higher from a 500 ml bottle compared to a Babyhaler in both young (25% v 12.5%, p = 0.005) and older children (42% v 22.5%, p = 0.003). A notable reduction in pulmonary deposition occurred at 50 months of age. CONCLUSION: A Babyhaler or Aerochamber produce equivalent lung deposition of aerosol. There is no difference in lung deposition when a mask or mouthpiece is used. A modified 500 ml plastic bottle produces greater pulmonary aerosol deposition than a conventional small volume spacer.
Authors: P C Ng; C W Lam; C H Lee; G W Wong; T F Fok; E Wong; K C Ma; I H Chan Journal: Arch Dis Child Fetal Neonatal Ed Date: 2000-11 Impact factor: 5.747