Incorrect echocardiographic diagnosis in patients with mechanical prosthetic valve dysfunction: correlation with surgical findings.

F Faletra1, C Constantin, F De Chiara, G Masciocco, G Santambrogio, A Moreo, A Alberti, E Vitali, A Pellegrini.   

Abstract

PURPOSE: To identify the rate of occurrence and type of incorrect echocardiographic diagnoses in patients with mechanical valve prostheses. PATIENTS AND METHODS: We studied 170 consecutive patients (73 women and 97 men) with a total of 208 prostheses who underwent surgery for mitral (n = 136) or aortic (n = 72) valve dysfunction between January 1991 and December 1997. Preoperative echocardiographic data were compared with surgical findings. Any major discrepancy between the echocardiographic reports and surgery was judged to be unconfirmed when the preoperative echocardiographic diagnosis was not confirmed at surgery, but the prosthesis was found to be dysfunctioning; and was judged to be erroneous when the preoperative echocardiographic diagnosis was not confirmed, and surgical inspection failed to reveal any other prosthetic abnormality.
RESULTS: There were 25 (12%) diagnostic errors. Of the 136 mitral prostheses, there were 9 unconfirmed diagnoses of paravalvular regurgitation (6 had a fibrous tissue overgrowth, 1 had a thrombus with fibrous tissue overgrowth, 1 had endocarditis vegetations, and 1 had a ball variance) and 5 erroneous diagnoses. Eleven diagnostic errors were made in the 72 aortic prostheses: there were 9 unconfirmed diagnoses (paravalvular regurgitation was diagnosed as transvalvular in 7, and transvalvular regurgitation as paravalvular in 2 cases), and 2 erroneous diagnoses.
CONCLUSIONS: Although echocardiography has gained great credibility among clinicians, special care should be taken when assessing patients in whom prosthetic valve dysfunction is suspected.

Entities:  

Mesh:

Year:  2000        PMID: 10806281     DOI: 10.1016/s0002-9343(00)00344-2

Source DB:  PubMed          Journal:  Am J Med        ISSN: 0002-9343            Impact factor:   4.965


  7 in total

1.  Assessing prosthetic mitral valve regurgitation by transoesophageal echo/Doppler.

Authors:  P S Rahko
Journal:  Heart       Date:  2004-05       Impact factor: 5.994

Review 2.  Fact or Artifact in Two-Dimensional Echocardiography: Avoiding Misdiagnosis and Missed Diagnosis.

Authors:  Philippe B Bertrand; Robert A Levine; Eric M Isselbacher; Pieter M Vandervoort
Journal:  J Am Soc Echocardiogr       Date:  2016-03-09       Impact factor: 5.251

3.  Assessment of severity of mechanical prosthetic mitral regurgitation by transoesophageal echocardiography.

Authors:  A Vitarelli; Y Conde; E Cimino; T Leone; I D'Angeli; S D'Orazio; S Stellato
Journal:  Heart       Date:  2004-05       Impact factor: 5.994

4.  When and how does nonstructural mechanical prosthetic heart valve dysfunction occur?

Authors:  Yoshio Misawa; Tsutomu Saito; Hiroaki Konishi; Shin-ichi Oki; Yuichiro Kaminishi; Hideki Takahashi; Kei Aizawa; Osamu Kamisawa; Morito Kato; Katsuo Fuse
Journal:  Jpn J Thorac Cardiovasc Surg       Date:  2003-08

5.  Multidetector CT imaging of mechanical prosthetic heart valves: quantification of artifacts with a pulsatile in-vitro model.

Authors:  Petr Symersky; Ricardo P J Budde; Paul Westers; Bas A J M de Mol; Mathias Prokop
Journal:  Eur Radiol       Date:  2011-05-15       Impact factor: 5.315

6.  Prospective ECG triggering reduces prosthetic heart valve-induced artefacts compared with retrospective ECG gating on 256-slice CT.

Authors:  Petr Symersky; Jesse Habets; Paul Westers; Bas A J M de Mol; Mathias Prokop; Ricardo P J Budde
Journal:  Eur Radiol       Date:  2011-12-30       Impact factor: 5.315

Review 7.  A manifesto for cardiovascular imaging: addressing the human factor.

Authors:  Alan G Fraser
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2017-12-01       Impact factor: 6.875