Literature DB >> 10798697

Thermal and SAR characterization of multielement dual concentric conductor microwave applicators for hyperthermia, a theoretical investigation.

F Rossetto1, C J Diederich, P R Stauffer.   

Abstract

Six aperture array dual concentric conductor (DCO) microwave hyperthermia applicators were studied using theoretical models to characterize power deposition (SAR) and steady state temperature distributions in perfused tissue. SAR patterns were calculated using the finite difference time domain (FDTD) numerical method, and were used as input to a finite difference thermal modeling program based on the Pennes Bio-Heat Equation in order to calculate corresponding temperature distributions. Numerous array configurations were investigated including the use of different size DCC apertures (2, 3, and 4 cm), different spacing between apertures (1.0-2.0 cm), and different water bolus thicknesses (5-15 mm). Thermal simulations were repeated using blood perfusion values ranging from 0.5 to 5 kg/m3 s. Results demonstrate the ability of DCC array applicators to effectively and uniformly heat tissue down to a depth of 7.5-10 mm below the skin surface for a large number of different combinations of DCC element size, spacing, and water bolus thickness. Results also reveal the close correlation between SAR patterns and corresponding temperature distributions, verifying that design studies of the applicator can be performed confidently by analysis of SAR, from which the thermal behavior can be estimated. These simulations are useful in the design optimization of large microwave DCC array applicators for superficial tissue heating and for identifying appropriate aperture spacing and bolus thickness parameters for different size DCC aperture arrays and tissue blood perfusion conditions.

Entities:  

Mesh:

Year:  2000        PMID: 10798697     DOI: 10.1118/1.598937

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  11 in total

1.  Characterization of a digital microwave radiometry system for noninvasive thermometry using a temperature-controlled homogeneous test load.

Authors:  K Arunachalam; P R Stauffer; P F Maccarini; S Jacobsen; F Sterzer
Journal:  Phys Med Biol       Date:  2008-06-30       Impact factor: 3.609

2.  Performance evaluation of a conformal thermal monitoring sheet sensor array for measurement of surface temperature distributions during superficial hyperthermia treatments.

Authors:  K Arunachalam; P Maccarini; T Juang; C Gaeta; P R Stauffer
Journal:  Int J Hyperthermia       Date:  2008-06       Impact factor: 3.914

3.  Shaping and resizing of multifed slot radiators used in conformal microwave antenna arrays for hyperthermia treatment of large superficial diseases.

Authors:  Paolo F Maccarini; Kavitha Arunachalam; Titania Juang; Valeria De Luca; Sneha Rangarao; Daniel Neumann; Carlos Daniel Martins; Oana Craciunescu; Paul R Stauffer
Journal:  Int Conf Electromagn Adv Appl       Date:  2009

4.  Non-invasive vesicoureteral reflux detection: heating risk studies for a new device.

Authors:  B W Snow; K Arunachalam; V De Luca; P F Maccarini; O Klemetsen; Y Birkelund; T J Pysher; P R Stauffer
Journal:  J Pediatr Urol       Date:  2011-06-12       Impact factor: 1.830

5.  Progress on ThermoBrachytherapy Surface Applicator for Superficial Tissue Diseases.

Authors:  Kavitha Arunachalam; Oana I Craciunescu; Paolo F Maccarini; Jaime L Schlorff; Edward Markowitz; Paul R Stauffer
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-02-12

Review 6.  Conformal microwave array (CMA) applicators for hyperthermia of diffuse chest wall recurrence.

Authors:  Paul R Stauffer; Paolo Maccarini; Kavitha Arunachalam; Oana Craciunescu; Chris Diederich; Titania Juang; Francesca Rossetto; Jaime Schlorff; Andrew Milligan; Joe Hsu; Penny Sneed; Zeljko Vujaskovic
Journal:  Int J Hyperthermia       Date:  2010       Impact factor: 3.914

7.  Design of a water coupling bolus with improved flow distribution for multi-element superficial hyperthermia applicators.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Jaime L Schlorff; Yngve Birkelund; Svein Jacobsen; Paul R Stauffer
Journal:  Int J Hyperthermia       Date:  2009-11       Impact factor: 3.914

8.  A thermal monitoring sheet with low influence from adjacent waterbolus for tissue surface thermometry during clinical hyperthermia.

Authors:  Kavitha Arunachalam; Paolo F Maccarini; Paul R Stauffer
Journal:  IEEE Trans Biomed Eng       Date:  2008-10       Impact factor: 4.538

9.  Microwave Radiometry for Non-Invasive Detection of Vesicoureteral Reflux (VUR) Following Bladder Warming.

Authors:  Paul R Stauffer; Paolo F Maccarini; Kavitha Arunachalam; Valeria De Luca; Sara Salahi; Alina Boico; Oystein Klemetsen; Yngve Birkelund; Svein K Jacobsen; Fernando Bardati; Piero Tognolatti; Brent Snow
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2011-02-22

10.  Size reduction and radiation pattern shaping of multi-fed DCC slot antennas used in conformal microwave array hyperthermia applicators.

Authors:  Paolo F Maccarini; Kavitha Arunachalam; Carlos D Martins; Paul R Stauffer
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2009-02-23
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.