Literature DB >> 10783561

Prospective study on the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms.

K Hagemann1, D Vollmer, T Niegel, U Ehmer, I Reuter.   

Abstract

The introduction of digital X-ray techniques offered a variety of new possibilities for digital image enhancement and exposure reduction. In order to compare the reproducibility of cephalometric landmarks on conventional and digital lateral headfilms 100 digital and 100 conventional lateral headfilms of patients attending our clinic were randomly selected. The digital cephalograms were obtained using storage phosphor plates in standard X-ray cassettes. All X-rays had been taken at 77 kV. For the digital images the mAs settings for conventional images minus 4 mAs were used. Two orthodontists traced each X-ray twice (21 reference points) at an interval of at least 1 week. The tracings were superimposed and the distances between the tracings of identical reference points were registered. The average reproducibility of cephalometric landmarks was significantly higher on the digitally obtained images, despite a reduction of radiation exposure of 23.7% in the digital images.

Entities:  

Mesh:

Year:  2000        PMID: 10783561     DOI: 10.1007/bf01300351

Source DB:  PubMed          Journal:  J Orofac Orthop        ISSN: 1434-5293            Impact factor:   1.938


  13 in total

1.  [A comparative study of the possibility of reducing the dosage in lateral teleradiographs].

Authors:  T Ruppenthal; B Fricke; H G Sergl; G Doll
Journal:  Fortschr Kieferorthop       Date:  1992-02

2.  Digital radiology--a realistic prospect?

Authors:  R Dawood
Journal:  Clin Radiol       Date:  1990-07       Impact factor: 2.350

3.  Analysis of low-dose digital lateral cephalometric radiographs.

Authors:  E B Näslund; M Kruger; A Petersson; K Hansen
Journal:  Dentomaxillofac Radiol       Date:  1998-05       Impact factor: 2.419

4.  Digital imaging of cephalometric radiographs, Part 2: Image quality.

Authors:  D B Forsyth; W C Shaw; S Richmond; C T Roberts
Journal:  Angle Orthod       Date:  1996       Impact factor: 2.079

5.  [Digital x-ray technics in practice. The annual meeting of the Swiss Society for Dentomaxillofacial Radiology of 7 March 1997 in Basel].

Authors:  I Hitz; M Asal
Journal:  Schweiz Monatsschr Zahnmed       Date:  1997

6.  Exposure reduction in cephalography with a digital photostimulable phosphor imaging system.

Authors:  K Seki; T Okano
Journal:  Dentomaxillofac Radiol       Date:  1993-08       Impact factor: 2.419

7.  Reliability of landmark recording on film and digital lateral cephalograms.

Authors:  V Macrì; A Wenzel
Journal:  Eur J Orthod       Date:  1993-04       Impact factor: 3.075

8.  [Digital imaging. A report on the 3rd Symposium on Digital Imaging in Dental Radiology of 13-15 October 1994 in Noordwijkerhout, the Netherlands].

Authors:  W Bürgin; U Brägger
Journal:  Schweiz Monatsschr Zahnmed       Date:  1995

9.  [Possibilities and limits of digital imaging].

Authors:  F Gudden
Journal:  Rontgenblatter       Date:  1984-12

10.  Computed radiography utilizing scanning laser stimulated luminescence.

Authors:  M Sonoda; M Takano; J Miyahara; H Kato
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

View more
  2 in total

1.  Coordinating bracket torque and incisor inclination : Part 2: Reproducibility and statistical measures of the torque coordination angle (TCA).

Authors:  H Sino; B Zimmer; I Schelper; S Schenk-Kazan; F Streibelt
Journal:  J Orofac Orthop       Date:  2018-03-09       Impact factor: 1.938

2.  Evaluation of the CT scanogram for assessment of craniofacial morphology.

Authors:  Francis C C Lee; Joseph Harold Noar; Robert David Evans
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

  2 in total