Literature DB >> 10772355

Using localization data from image interpretations to improve estimates of performance accuracy.

R G Swensson1.   

Abstract

A recently developed model uses the localization of abnormalities on images to improve statistical precision in measuring detection accuracy Az, the area below an observer's receiver operating characteristic (ROC) curve for ratings of sampled normal and abnormal cases. This study evaluated that improvement by investigating how much the standard error of estimated Az decreased when the statistical analysis included localization data. Comparisons of analyses with vs without localizations were made for: 1) the estimates of Az from observers' rating ROC curves for nodular lesions on clinical chest films and liver CT scans; 2) the probability of correct choices between paired samples of normal and abnormal cases (equivalent to Az); and 3) the sampling distributions of Az measured in Monte Carlo simulations of 2,000 independent rating experiments. Localization information considerably improved the precision of Az estimates, particularly when detection accuracy was low (Az approximately 0.60). These data provided roughly the same benefits in estimation precision as would two-to-fourfold increases in the sizes of both 1) the samples of positive and negative cases and 2) the observer samples used to estimate Az means.

Entities:  

Mesh:

Year:  2000        PMID: 10772355     DOI: 10.1177/0272989X0002000203

Source DB:  PubMed          Journal:  Med Decis Making        ISSN: 0272-989X            Impact factor:   2.583


  6 in total

1.  A nonparametric procedure for comparing the areas under correlated LROC curves.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2012-06-18       Impact factor: 10.048

2.  Estimation receiver operating characteristic curve and ideal observers for combined detection/estimation tasks.

Authors:  Eric Clarkson
Journal:  J Opt Soc Am A Opt Image Sci Vis       Date:  2007-12       Impact factor: 2.129

3.  Model for the detection of signals in images with multiple suspicious locations.

Authors:  Lucreţiu M Popescu
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

4.  Effect of Scan Time on Oncologic Lesion Detection in Whole-Body PET.

Authors:  Dan J Kadrmas; M Bugrahan Oktay; Michael E Casey; James J Hamill
Journal:  IEEE Trans Nucl Sci       Date:  2012-10       Impact factor: 1.679

Review 5.  New developments in observer performance methodology in medical imaging.

Authors:  Dev P Chakraborty
Journal:  Semin Nucl Med       Date:  2011-11       Impact factor: 4.446

6.  Decision theory applied to image quality control in radiology.

Authors:  Patrícia S Lessa; Cristofer A Caous; Paula R Arantes; Edson Amaro; Fernando M Campello de Souza
Journal:  BMC Med Inform Decis Mak       Date:  2008-11-13       Impact factor: 2.796

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.