Literature DB >> 10772019

VIP-Man: an image-based whole-body adult male model constructed from color photographs of the Visible Human Project for multi-particle Monte Carlo calculations.

X G Xu1, T C Chao, A Bozkurt.   

Abstract

Human anatomical models have been indispensable to radiation protection dosimetry using Monte Carlo calculations. Existing MIRD-based mathematical models are easy to compute and standardize, but they are simplified and crude compared to human anatomy. This article describes the development of an image-based whole-body model, called VIP-Man, using transversal color photographic images obtained from the National Library of Medicine's Visible Human Project for Monte Carlo organ dose calculations involving photons, electron, neutrons, and protons. As the first of a series of papers on dose calculations based on VIP-Man, this article provides detailed information about how to construct an image-based model, as well as how to adopt it into well-tested Monte Carlo codes, EGS4, MCNP4B, and MCNPX.

Entities:  

Mesh:

Year:  2000        PMID: 10772019     DOI: 10.1097/00004032-200005000-00003

Source DB:  PubMed          Journal:  Health Phys        ISSN: 0017-9078            Impact factor:   1.316


  38 in total

Review 1.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

2.  SAF values for internal photon emitters calculated for the RPI-P pregnant-female models using Monte Carlo methods.

Authors:  C Y Shi; X George Xu; Michael G Stabin
Journal:  Med Phys       Date:  2008-07       Impact factor: 4.071

3.  Specific absorbed fractions for internal electron emitters derived for a set of anatomically realistic reference pregnant female models.

Authors:  Bingqi Guo; X George Xu; Chengyu Shi
Journal:  Radiat Prot Dosimetry       Date:  2009-09-18       Impact factor: 0.972

4.  Size-specific dose estimate (SSDE) provides a simple method to calculate organ dose for pediatric CT examinations.

Authors:  Bria M Moore; Samuel L Brady; Amy E Mirro; Robert A Kaufman
Journal:  Med Phys       Date:  2014-07       Impact factor: 4.071

Review 5.  Task-based measures of image quality and their relation to radiation dose and patient risk.

Authors:  Harrison H Barrett; Kyle J Myers; Christoph Hoeschen; Matthew A Kupinski; Mark P Little
Journal:  Phys Med Biol       Date:  2015-01-07       Impact factor: 3.609

6.  Advances in Computational Human Phantoms and Their Applications in Biomedical Engineering - A Topical Review.

Authors:  Wolfgang Kainz; Esra Neufeld; Wesley E Bolch; Christian G Graff; Chan Hyeong Kim; Niels Kuster; Bryn Lloyd; Tina Morrison; Paul Segars; Yeon Soo Yeom; Maria Zankl; X George Xu; Benjamin M W Tsui
Journal:  IEEE Trans Radiat Plasma Med Sci       Date:  2019-01

Review 7.  A Review of Numerical Simulation and Analytical Modeling for Medical Devices Safety in MRI.

Authors:  J Kabil; L Belguerras; S Trattnig; C Pasquier; J Felblinger; A Missoffe
Journal:  Yearb Med Inform       Date:  2016-11-10

8.  A study of the shielding used to reduce leakage and scattered radiation to the fetus in a pregnant patient treated with a 6-MV external X-ray beam.

Authors:  Bin Han; Bryan Bednarz; X George Xu
Journal:  Health Phys       Date:  2009-12       Impact factor: 1.316

9.  A compartment model of VEGF distribution in humans in the presence of soluble VEGF receptor-1 acting as a ligand trap.

Authors:  Florence T H Wu; Marianne O Stefanini; Feilim Mac Gabhann; Aleksander S Popel
Journal:  PLoS One       Date:  2009-04-08       Impact factor: 3.240

10.  Development of a geometry-based respiratory motion-simulating patient model for radiation treatment dosimetry.

Authors:  Juying Zhang; George X Xu; Chengyu Shi; Martin Fuss
Journal:  J Appl Clin Med Phys       Date:  2008-01-21       Impact factor: 2.102

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.