Computer-assisted surgery in posterior instrumentation of the cervical spine: an in-vitro feasibility study.

M Richter1, L P Amiot, S Neller, P Kluger, W Puhl.   

Abstract

Transarticular C1/2 screws are widely used in posterior cervical spine instrumentation. The use of pedicle screws in the cervical spine remains uncommon. Due to superior biomechanical stability compared to lateral mass screws, pedicle screws can be used, especially for patients with poor bone quality or defects in the anterior column. Nevertheless there are potential risks of iatrogenic damage to the spinal cord, nerve roots or the vertebral artery associated with both posterior cervical spine instrumentation techniques. Therefore, the aim of this study was to evaluate whether C1/2 transarticular screws as well as transpedicular screws in C3 and C4 can be applied safely and with high accuracy using a computer-assisted surgery (CAS) system. We used 13 human cadaver C0-C5 spine segments. We installed 1.4-mm Kirschner wires transarticular in C 1/2, using a specially designed guide, and drilled 2.5-mm pedicle holes in C3 and C4 with the assistance of the CAS system. Hole positions were evaluated by palpation, CT and dissection. Forty-eight (92%) of the 52 drilled pedicles were correctly positioned after palpation, imaging and dissection. The vertebral artery was not injured in any specimen. All of the 26 C1/2 Kirschner wires were placed properly after imaging and dissection evaluations. No injury to vascular or bony structures was observed. C /2 transarticular screws as well as transpedicular screws in the cervical spine can be applied safely and with high accuracy using a CAS system in vitro. Therefore, this technique may be used in a clinical setting, as it offers improved accuracy and reduced radiation dose for the patient and the medical staff. Nevertheless, users should take note of known sources of possible faults causing inaccuracies in order to prevent iatrogenic damage. Small pedicles, with a diameter of less than 4.0 mm, may not be suitable for pedicle screws.

Entities:  

Mesh:

Year:  2000        PMID: 10766060      PMCID: PMC3611447          DOI: 10.1007/pl00010024

Source DB:  PubMed          Journal:  Eur Spine J        ISSN: 0940-6719            Impact factor:   3.134


  26 in total

1.  Computer-assisted posterior instrumentation of the cervical and cervico-thoracic spine.

Authors:  Marcus Richter; Thomas Mattes; Balkan Cakir
Journal:  Eur Spine J       Date:  2003-11-22       Impact factor: 3.134

2.  [Computer-assisted surgery-(CAS-)guided correction arthrodesis of the subtalar joint].

Authors:  Martinus Richter
Journal:  Oper Orthop Traumatol       Date:  2010-10       Impact factor: 1.154

3.  CT evaluation of cervical pedicle in a Chinese population for surgical application of transpedicular screw placement.

Authors:  Zhu Ruofu; Yang Huilin; Hu Xiaoyun; He Xishun; Tang Tiansi; Chen Liang; Li Xigong
Journal:  Surg Radiol Anat       Date:  2008-03-20       Impact factor: 1.246

4.  Cervical anterior transpedicular screw fixation (ATPS)--Part II. Accuracy of manual insertion and pull-out strength of ATPS.

Authors:  Heiko Koller; Frank Acosta; Mark Tauber; Michael Fox; Hudelmaier Martin; Rosmarie Forstner; Peter Augat; Rainer Penzkofer; Christian Pirich; H Kässmann; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

5.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

6.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

7.  Computer aided surgery in foot and ankle: applications and perspectives.

Authors:  Martinus Richter
Journal:  Int Orthop       Date:  2013-05-25       Impact factor: 3.075

Review 8.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.

Authors:  Rajeev Verma; Sonal Krishan; Kurt Haendlmayer; A Mohsen
Journal:  Eur Spine J       Date:  2010-01-06       Impact factor: 3.134

9.  Cervical pedicle screw insertion using the technique with direct exposure of the pedicle by laminoforaminotomy.

Authors:  Dae-Jean Jo; Eun-Min Seo; Ki-Tack Kim; Sung-Min Kim; Sang-Hun Lee
Journal:  J Korean Neurosurg Soc       Date:  2012-11-30

10.  Iso-C3D navigation assisted pedicle screw placement in deformities of the cervical and thoracic spine.

Authors:  Vinod V Rajan; Vijay Kamath; Ajoy Prasad Shetty; S Rajasekaran
Journal:  Indian J Orthop       Date:  2010-04       Impact factor: 1.251

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.