Literature DB >> 10758928

Suture-mediated closure of the femoral access site after cardiac catheterization: results of the suture to ambulate aNd discharge (STAND I and STAND II) trials.

D S Baim1, W D Knopf, T Hinohara, D E Schwarten, R A Schatz, C A Pinkerton, D E Cutlip, M Fitzpatrick, K K Ho, R E Kuntz.   

Abstract

Despite advances in other aspects of cardiac catheterization, manual or mechanical compression followed by 4 to 8 hours of bed rest remains the mainstay of postprocedural femoral access site management. Suture-mediated closure may prove to be an effective alternative, offering earlier sheath removal and ambulation, and potentially a reduction in hemorrhagic complications. The Suture To Ambulate aNd Discharge trial (STAND I) evaluated the 6Fr Techstar device in 200 patients undergoing diagnostic procedures, with successful hemostasis achieved in 99% of patients (94% with suture closure only) in a median of 13 minutes, and 1% major complications. STAND II randomized 515 patients undergoing diagnostic or interventional procedures to use of the 8Fr or 10Fr Prostar-Plus device versus traditional compression. Successful suture-mediated hemostasis was achieved in 97.6% of patients (91.2% by the device alone) compared with 98.9% of patients with compression (p = NS). Major complication rates were 2.4% and 1.1%, and met the Blackwelder's test for equivalency (p <0.05). Median time to hemostasis (19 vs 243 minutes, p <0.01) and time to ambulation (3.9 vs 14.8 hours, p <0.01) were significantly shorter for suture-mediated closure. Suture-mediated closure of the arterial puncture site thus affords reliable immediate hemostasis and shortens the time to ambulation without significantly increasing the risk of local complications.

Entities:  

Mesh:

Year:  2000        PMID: 10758928     DOI: 10.1016/s0002-9149(99)00882-6

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  15 in total

Review 1.  Efficacy and safety of the perclose closer s device after neurointerventional procedures: prospective study and literature review.

Authors:  Kamran Khaghany; Firas Al-Ali; Thomas Spigelmoyer; Ron Pimentel; Kurt Wharton
Journal:  AJNR Am J Neuroradiol       Date:  2005 Jun-Jul       Impact factor: 3.825

2.  Bleeding complications after contemporary pharmacoinvasive therapy for ST elevation myocardial infarction.

Authors:  Matthew J Gutierrez; Atul Aggarwal; Kristin Gilbert; Burton E Sobel; Harold L Dauerman
Journal:  J Thromb Thrombolysis       Date:  2004-12       Impact factor: 2.300

3.  The use of vascular closure devices and impact on major bleeding and net adverse clinical events (NACEs) in balloon aortic valvuloplasty: a sub-analysis of the BRAVO study.

Authors:  Brian O'Neill; Vikas Singh; Annapoorna Kini; Roxana Mehran; Evan Jacobs; David Knopf; Carlos E Alfonso; Claudia A Martinez; Pedro Martinezclark; William O'Neill; Alan W Heldman; Jennifer Yu; Usman Baber; Jason C Kovacic; George Dangas; Samin Sharma; Samantha Sartori; Mauricio G Cohen
Journal:  Catheter Cardiovasc Interv       Date:  2013-03-25       Impact factor: 2.692

4.  The AmBulatory Closure Device Percutaneous Intervention (ABCD-PCI) study: a single-center experience.

Authors:  Adam M Falcone; Rahul Bose; Robert C Stoler; Michael Kim; Emily Laible; Lucy Kang; Kim Waters; Janet Dunkerley; James W Choi
Journal:  Proc (Bayl Univ Med Cent)       Date:  2011-07

5.  Usefulness of a Nonsuture Closure Device in Patients Undergoing Diagnostic Coronary and Peripheral Angiography.

Authors:  John T Owens; Shaun Bhatty; Robert J Donovan; Andrea Tordini; Peter Danyi; Kalpesh Patel; Jacob A Wegelin; Ion S Jovin
Journal:  Int J Angiol       Date:  2017-10-04

Review 6.  How serious a problem is bleeding in patients with acute coronary syndromes?

Authors:  Usman Baber; Jason Kovacic; Annapoorna S Kini; Samin K Sharma; George Dangas; Roxana Mehran
Journal:  Curr Cardiol Rep       Date:  2011-08       Impact factor: 2.931

Review 7.  Anticoagulation During AF Ablation: The Balance between Thromboembolism and Bleeding.

Authors:  Jennifer A Mears; Samuel J Asirvatham
Journal:  J Atr Fibrillation       Date:  2009-02-01

8.  Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

Authors:  Antonio E Dager; Rutger-Jan Nuis; Bernardo Caicedo; Jaime A Fonseca; Camilo Arana; Lidsa Cruz; Luis M Benitez; Carlos A Nader; Eduardo Duenas; Eduardo J de Marchena; William W O'Neill; Peter P de Jaegere
Journal:  Tex Heart Inst J       Date:  2012

9.  The safety and efficacy of the Angio-Seal closure device in diagnostic and interventional neuroangiography setting: a single-center experience with 1,443 closures.

Authors:  Serdar Geyik; Kivilcim Yavuz; Ayca Akgoz; Osman Koc; Bora Peynircioglu; Barbaros Cil; Saruhan Cekirge; Isil Saatci
Journal:  Neuroradiology       Date:  2007-06-27       Impact factor: 2.804

10.  Safety and efficacy of the Perclose suture-mediated closure device following carotid artery stenting under clopidogrel platelet blockade.

Authors:  Niels Zorger; Thomas Finkenzeller; Markus Lenhart; Okka Hamer; Christian Paetzel; Inghita Borisch; Ingolf Toepel; Stefan Feuerbach; Johann Link
Journal:  Eur Radiol       Date:  2003-11-11       Impact factor: 5.315

View more