MR arthrography of the shoulder and hip after fluoroscopic landmarking.

T T Miller1.   

Abstract

PURPOSE: To describe a technique for intra-articular injection in the MR suite after conventional fluoroscopic landmarking in order to streamline MR arthrography. DESIGN AND PATIENTS: This technique was performed on 33 consecutive patients referred for MR arthrography of the shoulder to evaluate the glenoid labrum and on 15 consecutive patients referred for MR arthrography of the hip to evaluate the acetabular labrum. The patients were landmarked in the fluoroscopy suite, followed by a conventional MR examination. The intra-articular injection was then performed on the MR table and the MR arthrographic sequences obtained.
RESULTS: One of the 48 injections was extra-articular, requiring a second injection. The other injections were performed without incident, and the average total procedure time for all injections was 10 min.
CONCLUSIONS: This technique is a reliable method of streamlining intra-articular injections when performing conventional MR imaging prior to the MR arthrographic portion of the examination. It shortens the total MR examination time by eliminating a visit to the fluoroscopy suite in the middle of the MR study, and its use of a straight anterior approach for both the shoulder and hip joints should be familiar to most people who perform conventional arthrography.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10741495     DOI: 10.1007/s002560050014

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  4 in total

1.  Prospective evaluation of two different injection techniques for MR arthrography of the hip.

Authors:  Sylvain R Duc; Juerg Hodler; Marius R Schmid; Marco Zanetti; Bernard Mengiardi; Claudio Dora; Christian W A Pfirrmann
Journal:  Eur Radiol       Date:  2005-08-16       Impact factor: 5.315

2.  Augmented reality visualization with use of image overlay technology for MR imaging-guided interventions: assessment of performance in cadaveric shoulder and hip arthrography at 1.5 T.

Authors:  Jan Fritz; Paweena U-Thainual; Tamas Ungi; Aaron J Flammang; Gabor Fichtinger; Iulian I Iordachita; John A Carrino
Journal:  Radiology       Date:  2012-07-27       Impact factor: 11.105

3.  Magnetic resonance arthrography of the hip: technique and spectrum of findings in younger patients.

Authors:  Sébastien Aubry; Danny Bélanger; Caroline Giguère; Martin Lavigne
Journal:  Insights Imaging       Date:  2010-06-08

4.  Glenohumeral joint injection: a comparative study of ultrasound and fluoroscopically guided techniques before MR arthrography.

Authors:  Matthieu J C M Rutten; James M P Collins; Bas J Maresch; Jacques H J M Smeets; Caroline M M Janssen; Lambertus A L M Kiemeney; Gerrit J Jager
Journal:  Eur Radiol       Date:  2008-10-29       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.