Literature DB >> 10730643

Contrast-enhanced transcranial color-coded duplexsonography in stroke patients with limited bone windows.

G Gahn1, J Gerber, S Hallmeyer, G Hahn, R H Ackerman, H Reichmann, R von Kummer.   

Abstract

BACKGROUND AND
PURPOSE: Thickening of the temporal bone in stroke-age patients may obviate sonographic evaluation of the circle of Willis in 20% to 30% of patients. We assessed the diagnostic efficacy of contrast-enhanced transcranial color-coded duplexsonography (TCCD) for noninvasive evaluation of the circle of Willis in stroke patients with limited bone windows.
METHODS: Of 171 consecutive patients who presented with ischemic symptoms in the middle cerebral artery (MCA) territory, 49 patients (32 female, 17 male; age range, 70.5+/-10.6 years) had no detectable colorflow signals from the circle of Willis by TCCD because of limited acoustic windows. These 49 patients received an IV injection of a sonographic contrast-enhancing agent, Levovist (Schering; Berlin, Germany), and were re-examined. Correlative imaging studies of the circle of Willis were obtained in 42 of 49 of these patients.
RESULTS: In 38 of 49 patients, contrast-enhanced TCCD enabled full visualization of the circle of Willis bilaterally; in an additional five patients, contrast-enhanced TCCD revealed only the portion of the circle of Willis ipsilateral to the probe through one temporal bone. In six of these 43 patients, contrast-enhanced TCCD showed MCA stenosis and MCA occlusion in three; three of the six cases of MCA stenosis and all three cases of the MCA occlusion were found on the symptomatic side. In six of 49 patients, no colorflow signals were obtained after contrast enhancement. All contrast-enhanced TCCD findings were confirmed by CT angiography, transfemoral digital subtraction angiography, MR angiography, or a combination of all three correlative studies. Levovist produced no serious adverse events.
CONCLUSION: In stroke-age patients with limited acoustic windows, contrast-enhancement with Levovist can markedly increase the sensitivity of TCCD and increase the detection of clinically relevant intracranial arterial disease.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10730643      PMCID: PMC8174973     

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  15 in total

1.  Transcranial color-coded real-time sonography in adults.

Authors:  U Bogdahn; G Becker; J Winkler; K Greiner; J Perez; B Meurers
Journal:  Stroke       Date:  1990-12       Impact factor: 7.914

2.  Diagnosis and monitoring of middle cerebral artery occlusion with contrast-enhanced transcranial color-coded real-time sonography in patients with inadequate acoustic bone windows.

Authors:  T Postert; B Braun; J Federlein; H Przuntek; O Köster; T Büttner
Journal:  Ultrasound Med Biol       Date:  1998-03       Impact factor: 2.998

3.  Role of CT angiography in patient selection for thrombolytic therapy in acute hemispheric stroke.

Authors:  S Wildermuth; M Knauth; T Brandt; R Winter; K Sartor; W Hacke
Journal:  Stroke       Date:  1998-05       Impact factor: 7.914

4.  Potential and limitations of echocontrast-enhanced ultrasonography in acute stroke patients: a pilot study.

Authors:  D G Nabavi; D W Droste; V Kemény; G Schulte-Altedorneburg; S Weber; E B Ringelstein
Journal:  Stroke       Date:  1998-05       Impact factor: 7.914

5.  Potential of CT angiography in acute ischemic stroke.

Authors:  M Knauth; R von Kummer; O Jansen; S Hähnel; A Dörfler; K Sartor
Journal:  AJNR Am J Neuroradiol       Date:  1997 Jun-Jul       Impact factor: 3.825

6.  Transcranial Doppler ultrasound for the assessment of intracranial arterial flow velocity--Part 2. Evaluation of intracranial arterial disease.

Authors:  M Hennerici; W Rautenberg; A Schwartz
Journal:  Surg Neurol       Date:  1987-06

7.  Clinical and instrumental evaluation of patients with ischemic stroke within the first six hours.

Authors:  C Fieschi; C Argentino; G L Lenzi; M L Sacchetti; D Toni; L Bozzao
Journal:  J Neurol Sci       Date:  1989-07       Impact factor: 3.181

8.  Rate of successful recording of blood flow signals in the middle cerebral artery using transcranial Doppler sonography.

Authors:  T Itoh; M Matsumoto; N Handa; H Maeda; H Hougaku; H Hashimoto; H Etani; Y Tsukamoto; T Kamada
Journal:  Stroke       Date:  1993-08       Impact factor: 7.914

9.  Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries.

Authors:  R Aaslid; T M Markwalder; H Nornes
Journal:  J Neurosurg       Date:  1982-12       Impact factor: 5.115

10.  Potential and limitations of transcranial color-coded sonography in stroke patients.

Authors:  G Seidel; M Kaps; T Gerriets
Journal:  Stroke       Date:  1995-11       Impact factor: 7.914

View more
  8 in total

Review 1.  [Ultrasound contrast agents].

Authors:  T Albrecht; J Hohmann
Journal:  Radiologe       Date:  2003-10       Impact factor: 0.635

2.  Echo-enhanced transcranial color-coded duplex sonography in the diagnosis of cerebrovascular events: a validation study.

Authors:  A Kunz; G Hahn; D Mucha; A Müller; K M Barrett; R von Kummer; G Gahn
Journal:  AJNR Am J Neuroradiol       Date:  2006 Nov-Dec       Impact factor: 3.825

3.  Simultaneous bilateral real-time 3-d transcranial ultrasound imaging at 1 MHz through poor acoustic windows.

Authors:  Brooks D Lindsey; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2013-02-13       Impact factor: 2.998

4.  The ultrasound brain helmet: new transducers and volume registration for in vivo simultaneous multi-transducer 3-D transcranial imaging.

Authors:  Brooks D Lindsey; Edward D Light; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-06       Impact factor: 2.725

5.  3-D transcranial ultrasound imaging with bilateral phase aberration correction of multiple isoplanatic patches: a pilot human study with microbubble contrast enhancement.

Authors:  Brooks D Lindsey; Heather A Nicoletto; Ellen R Bennett; Daniel T Laskowitz; Stephen W Smith
Journal:  Ultrasound Med Biol       Date:  2013-11-14       Impact factor: 2.998

6.  Refraction correction in 3D transcranial ultrasound imaging.

Authors:  Brooks D Lindsey; Stephen W Smith
Journal:  Ultrason Imaging       Date:  2014-01       Impact factor: 1.578

7.  MRA study on variation of the circle of willis in healthy Chinese male adults.

Authors:  Chuanya Qiu; Yong Zhang; Caixia Xue; Shanshan Jiang; Wei Zhang
Journal:  Biomed Res Int       Date:  2015-01-05       Impact factor: 3.411

8.  Comparison Between Transcranial Color-Coded Duplex Doppler and Contrast Enhanced Transcranial Color-Coded Duplex Doppler After Subarachnoid Aneurysmal Hemorrhage.

Authors:  Aurore Rodrigues; Virginie Tarazona; Alexandre Ladoux; Pierre Etienne Leblanc; Anatole Harrois; Bernard Vigué; Jacques Duranteau
Journal:  Neurocrit Care       Date:  2021-06-30       Impact factor: 3.210

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.