Literature DB >> 7143059

Noninvasive transcranial Doppler ultrasound recording of flow velocity in basal cerebral arteries.

R Aaslid, T M Markwalder, H Nornes.   

Abstract

In this report the authors describe a noninvasive transcranial method of determining the flow velocities in the basal cerebral arteries. Placement of the probe of a range-gated ultrasound Doppler instrument in the temporal area just above the zygomatic arch allowed the velocities in the middle cerebral artery (MCA) to be determined from the Doppler signals. The flow velocities in the proximal anterior (ACA) and posterior (PCA) cerebral arteries were also recorded at steady state and during test compression of the common carotid arteries. An investigation of 50 healthy subjects by this transcranial Doppler method revealed that the velocity in the MCA, ACA, and PCA was 62 +/- 12, 51 +/0 12, and 44 +/- 11 cm/sec, respectively. This method is of particular value for the detection of vasospasm following subarachnoid hemorrhage and for evaluating the cerebral circulation in occlusive disease of the carotid and vertebral arteries.

Entities:  

Mesh:

Year:  1982        PMID: 7143059     DOI: 10.3171/jns.1982.57.6.0769

Source DB:  PubMed          Journal:  J Neurosurg        ISSN: 0022-3085            Impact factor:   5.115


  468 in total

Review 1.  Transcranial Doppler ultrasonography monitoring of cerebral hemodynamics during performance of cognitive tasks: a review.

Authors:  N Stroobant; G Vingerhoets
Journal:  Neuropsychol Rev       Date:  2000-12       Impact factor: 7.444

2.  Assessment of the collateral function of the circle of Willis: three-dimensional time-of-flight MR angiography compared with transcranial color-coded duplex sonography.

Authors:  Arjan W J Hoksbergen; Charles B L Majoie; Frans-Jan H Hulsmans; Dink A Legemate
Journal:  AJNR Am J Neuroradiol       Date:  2003-03       Impact factor: 3.825

3.  Inter observer variability of the transcranial Doppler ultrasound technique: impact of lack of practice on the accuracy of measurement.

Authors:  Q Shen; J Stuart; B Venkatesh; J Wallace; J Lipman
Journal:  J Clin Monit Comput       Date:  1999-05       Impact factor: 2.502

Review 4.  Transcranial Doppler imaging in children: sickle cell screening and beyond.

Authors:  Lisa H Lowe; Dorothy I Bulas
Journal:  Pediatr Radiol       Date:  2004-08-24

5.  Thirteenth European Lecture. What can the doctor learn from his patient and what can the patient learn from his illness.

Authors:  A J van der Werf
Journal:  Acta Neurochir (Wien)       Date:  1992       Impact factor: 2.216

6.  Development of methods to analyse transcranial Doppler ultrasound signals recorded in microgravity.

Authors:  P J Vaitkus; K W Johnston; R L Bondar; F Stein; P A Bascom; L Mo; M Kassam; L C Chadwick; J Mehi; R S Cobbold
Journal:  Med Biol Eng Comput       Date:  1990-07       Impact factor: 2.602

7.  Cerebral hypoperfusion precedes nausea during centrifugation.

Authors:  Jorge M Serrador; Todd T Schlegel; F Owen Black; Scott J Wood
Journal:  Aviat Space Environ Med       Date:  2005-02

8.  Analysis of cerebral blood flow and intracranial hypertension in critical patients with non-hepatic hyperammonemia.

Authors:  Alexandre Sanches Larangeira; Marcos Toshiyuki Tanita; Marcos Antonio Dias; Olavo Franco Ferreira Filho; Vinicius Daher Alvares Delfino; Lucienne Tibery Queiroz Cardoso; Cintia Magalhães Carvalho Grion
Journal:  Metab Brain Dis       Date:  2018-05-03       Impact factor: 3.584

9.  Turbulence and circulating cerebral emboli detectable at Doppler ultrasonography: a differentiation study in a stenotic middle cerebral artery model.

Authors:  Yi Yang; Donald G Grosset; Qiu Li; Ashfaq Shuaib; Kennedy R Lees
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

10.  Pre- and intraoperative methods of controlling cerebral circulation in giant aneurysm surgery.

Authors:  H G Boecher-Schwarz; K Ungersboeck; P Ulrich; W Mueller-Forell; D Smolders; A Perneczky
Journal:  Neurosurg Rev       Date:  1995       Impact factor: 3.042

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.