Portal Imaging Technology: Past, Present, and Future.

.   

Abstract

Many different electronic portal imaging devices (EPIDs) have been developed to improve geometric accuracy in radiation therapy. This article describes the two types of EPIDs that have become available commercially-the television camera-based EPID and the matrix ion chamber EPID-as well as describing the amorphous silicon array, a device that may become available in the future for portal imaging. In addition, the various image registration techniques that identify geometric errors from the portal images are described. These include interactive techniques, landmark-based techniques, contrast-based techniques and hybrid techniques. Although great improvements in portal imaging technology have been made, more development needs to be directed towards making portal imaging convenient and reliable. Image quality must be improved further, to improve the robustness of image registration techniques and more thought must be given to integrating and automating the various steps in the image registration process. Otherwise, too much time will have to be devoted to these tasks. Finally, and most importantly, users will have to decide what is the best way of using EPIDs clinically. Much development is required before the full potential of this exciting technology can be realized.

Year:  1995        PMID: 10717134     DOI: 10.1054/SRAO00500115

Source DB:  PubMed          Journal:  Semin Radiat Oncol        ISSN: 1053-4296            Impact factor:   5.934


  6 in total

1.  Quality assurance for kilo- and megavoltage in-room imaging and localization for off- and online setup error correction.

Authors:  James M Balter; Larry E Antonuk
Journal:  Int J Radiat Oncol Biol Phys       Date:  2008       Impact factor: 7.038

2.  Monte Carlo-based adaptive EPID dose kernel accounting for different field size responses of imagers.

Authors:  Song Wang; Joseph K Gardner; John J Gordon; Weidong Li; Luke Clews; Peter B Greer; Jeffrey V Siebers
Journal:  Med Phys       Date:  2009-08       Impact factor: 4.071

3.  Implementation and application of real-time motion analysis based on passive markers.

Authors:  G Baroni; G Ferrigno; A Pedotti
Journal:  Med Biol Eng Comput       Date:  1998-11       Impact factor: 2.602

4.  ScintSim1: A new Monte Carlo simulation code for transport of optical photons in 2D arrays of scintillation detectors.

Authors:  Mohammad Amin Mosleh-Shirazi; Zinat Zarrini-Monfared; Sareh Karbasi; Ali Zamani
Journal:  J Med Phys       Date:  2014-01

5.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

6.  Using the frame averaging of aS500 EPID for IMRT verification.

Authors:  J Chang; C C Ling
Journal:  J Appl Clin Med Phys       Date:  2003       Impact factor: 2.102

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.