Implementation and application of real-time motion analysis based on passive markers.

G Baroni1, G Ferrigno, A Pedotti.   

Abstract

A method for real-time motion analysis based on passive markers is presented. An opto-electronic automatic motion analyser was used as hardware platform and the real-time operation was based on the interfacing between two levels of the system architecture. True real-time acquisition, processing and representation of two-dimensional and three-dimensional kinematics data were implemented through a newly conceived data acquisition procedure and high speed optimisation of the kinematics data processing. The method allows one to operate the motion analysis system in real-time; even when the data elaboration unit is required to perform other processing functions, the only consequence is a decrease in system sampling rate. The maximum number of processed and plotted markers in three dimensions at the highest system sampling rate (100 Hz) turned out to be suitable for the implementation of analytical and visual kinematics biofeedback. An example of the achievable level of complexity in terms of marker disposition model and graphic representation is reported by describing a demonstration of the real-time representation of human face movements. A clinical application of the method for patient position definition and control at radiotherapy units is presented.

Entities:  

Mesh:

Year:  1998        PMID: 10367459     DOI: 10.1007/bf02518871

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  13 in total

1.  Portal Imaging Technology: Past, Present, and Future.

Authors: 
Journal:  Semin Radiat Oncol       Date:  1995-04       Impact factor: 5.934

2.  An algorithm for 3-D automatic movement detection by means of standard TV cameras.

Authors:  N A Borghese; G Ferrigno
Journal:  IEEE Trans Biomed Eng       Date:  1990-12       Impact factor: 4.538

3.  Statistical comparison of DLT versus ILSSC in the calibration of a photogrammetric stereo-system.

Authors:  N A Borghese; P Cerveri; G C Ferrigno
Journal:  J Biomech       Date:  1997-04       Impact factor: 2.712

4.  Procedure to automatically classify markers in biomechanical analysis of whole-body movement in different sports activities.

Authors:  G Ferrigno; M Gussoni
Journal:  Med Biol Eng Comput       Date:  1988-05       Impact factor: 2.602

5.  New possibilities for human motion studies by real-time light spot position measurement.

Authors:  H J Woltring
Journal:  Biotelemetry       Date:  1974

6.  ELITE: a digital dedicated hardware system for movement analysis via real-time TV signal processing.

Authors:  G Ferrigno; A Pedotti
Journal:  IEEE Trans Biomed Eng       Date:  1985-11       Impact factor: 4.538

7.  Clinical use of on-line portal imaging for daily patient treatment verification.

Authors:  M G Herman; R A Abrams; R R Mayer
Journal:  Int J Radiat Oncol Biol Phys       Date:  1994-03-01       Impact factor: 7.038

8.  Optoelectric (Selspot) gait measurement in two- and three-dimensional space--a preliminary report.

Authors:  H J Woltring; E B Marsolais
Journal:  Bull Prosthet Res       Date:  1980

9.  Precise positioning of patients for radiation therapy.

Authors:  L J Verhey; M Goitein; P McNulty; J E Munzenrider; H D Suit
Journal:  Int J Radiat Oncol Biol Phys       Date:  1982-02       Impact factor: 7.038

10.  An automated motion measurement system for clinical gait analysis.

Authors:  K D Taylor; F M Mottier; D W Simmons; W Cohen; R Pavlak; D P Cornell; G B Hankins
Journal:  J Biomech       Date:  1982       Impact factor: 2.712

View more
  5 in total

1.  Evaluation of methods for opto-electronic body surface sensing applied to patient position control in breast radiation therapy.

Authors:  G Baroni; A Troia; M Riboldi; R Orecchia; G Ferrigno; A Pedotti
Journal:  Med Biol Eng Comput       Date:  2003-11       Impact factor: 2.602

2.  Deep inspiration breath-hold technique guided by an opto- electronic system for extracranial stereotactic treatments.

Authors:  Cristina Garibaldi; Gianpiero Catalano; Guido Baroni; Barbara Tagaste; Marco Riboldi; Maria Francesca Spadea; Mario Ciocca; Raffaella Cambria; Flavia Serafini; Roberto Orecchia
Journal:  J Appl Clin Med Phys       Date:  2013-07-08       Impact factor: 2.102

3.  An image-based method to synchronize cone-beam CT and optical surface tracking.

Authors:  Aurora Fassi; Joël Schaerer; Marco Riboldi; David Sarrut; Guido Baroni
Journal:  J Appl Clin Med Phys       Date:  2015-03-08       Impact factor: 2.102

4.  Motion compensation with a scanned ion beam: a technical feasibility study.

Authors:  Sven Oliver Grözinger; Christoph Bert; Thomas Haberer; Gerhard Kraft; Eike Rietzel
Journal:  Radiat Oncol       Date:  2008-10-14       Impact factor: 3.481

5.  Performance and characteristics of an IR localizing system for radiation therapy.

Authors:  Yulia Lyatskaya; Hsiao-Ming Lu; Lee Chin
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.