Literature DB >> 10711892

A comparison of tangent screen, goldmann, and humphrey perimetry in the detection and localization of occipital lesions.

A M Wong1, J A Sharpe.   

Abstract

OBJECTIVE: To compare manual kinetic perimetry with tangent screen and Goldmann techniques and automated static perimetry with the Humphrey Field Analyzer in the detection and localization of occipital lobe lesions.
DESIGN: Prospective consecutive comparative case series. PARTICIPANTS: Twelve patients with well-defined occipital lobe infarcts on magnetic resonance (MR) imaging were studied. MAIN OUTCOME MEASURES: The patients were tested by tangent screen, Goldmann, and Humphrey perimetry (central 30-2 threshold program). The three visual fields were compared and correlated with MR images.
RESULTS: All three perimetric techniques detected the presence of postchiasmal lesions. However, localization of lesions differed with perimetric technique. Visual fields obtained from tangent screen and Goldmann perimetry were similar and corresponded well with the location of lesions on MR images in all 12 patients. Humphrey perimetry inaccurately localized the lesion to the proximal part of the postchiasmal pathway by revealing incongruous fields in two patients, failed to detect sparing of the posterior occipital cortex or occipital pole in four patients, and estimated a larger extent of damage in one patient when compared with MR images and manual perimetry.
CONCLUSIONS: All three perimetric techniques are satisfactory screening tests to detect occipital lesions. However, tangent screen and Goldmann perimetry provide information about the location and extent of lesions that is more consistent with prevailing knowledge of the effects of the lesion in the postgeniculate visual pathway.

Entities:  

Mesh:

Year:  2000        PMID: 10711892     DOI: 10.1016/s0161-6420(99)00092-5

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  11 in total

1.  Efficiency of Rarebit perimetry in the evaluation of homonymous hemianopia in stroke patients.

Authors:  Sansal Gedik; Ahmet Akman; Yonca A Akova
Journal:  Br J Ophthalmol       Date:  2007-02-14       Impact factor: 4.638

2.  Traumatic homonymous hemianopia.

Authors:  B B Bruce; X Zhang; S Kedar; N J Newman; V Biousse
Journal:  J Neurol Neurosurg Psychiatry       Date:  2006-03-30       Impact factor: 10.154

3.  Functional organization of human visual cortex in occipital polymicrogyria.

Authors:  Serge O Dumoulin; Jeffrey D Jirsch; Andrea Bernasconi
Journal:  Hum Brain Mapp       Date:  2007-12       Impact factor: 5.038

4.  A computerized perimeter for assessing modality-specific visual field loss.

Authors:  Finnegan J Calabro; Lucia M Vaina
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2011

5.  The volume of tumor mass and visual field defect in patients with pituitary macroadenoma.

Authors:  Jung Pil Lee; In Won Park; Yun Suk Chung
Journal:  Korean J Ophthalmol       Date:  2011-01-17

6.  Visual Field Progression in Retinitis Pigmentosa.

Authors:  Manlong Xu; Yi Zhai; Ian M MacDonald
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-06-03       Impact factor: 4.799

7.  Comparative evaluation of Octopus semi-automated kinetic perimeter with Humphrey and Goldmann perimeters in neuro-ophthalmic disorders.

Authors:  Karthika Bhaskaran; Swati Phuljhele; Pawan Kumar; Rohit Saxena; Dewang Angmo; Pradeep Sharma
Journal:  Indian J Ophthalmol       Date:  2021-04       Impact factor: 1.848

8.  Comparison of octopus semi-automated kinetic perimetry and humphrey peripheral static perimetry in neuro-ophthalmic cases.

Authors:  Fiona J Rowe; Carmel Noonan; Melanie Manuel
Journal:  ISRN Ophthalmol       Date:  2013-07-15

Review 9.  Programme choice for perimetry in neurological conditions (PoPiN): a systematic review of perimetry options and patterns of visual field loss.

Authors:  Lauren R Hepworth; Fiona J Rowe
Journal:  BMC Ophthalmol       Date:  2018-09-10       Impact factor: 2.209

10.  Differences in Static and Kinetic Perimetry Results are Eliminated in Retinal Disease when Psychophysical Procedures are Equated.

Authors:  Jack Phu; Michael Kalloniatis; Henrietta Wang; Sieu K Khuu
Journal:  Transl Vis Sci Technol       Date:  2018-10-01       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.