Literature DB >> 10710004

Quantification of age-related changes in the structure model type and trabecular thickness of human tibial cancellous bone.

M Ding1, I Hvid.   

Abstract

Structure model type and trabecular thickness are important characteristics in describing cancellous bone architecture. It has been qualitatively observed that a radical change of trabeculae from plate-like to rod-like occurs in aging, bone remodeling, and osteoporosis. Thickness of trabeculae has traditionally been measured using model-based histomorphometric methods on two-dimensional (2-D) sections. However, no quantitative study has been published based on three-dimensional (3-D) methods on the age-related changes in structure model type and trabecular thickness for human peripheral (tibial) cancellous bone. In this study, 160 human proximal tibial cancellous bone specimens from 40 normal donors, aged 16 to 85 years, were collected. These specimens were micro-computed tomography (micro-CT) scanned, then the micro-CT images were segmented using optimal thresholds. From accurate 3-D data sets, structure model type and trabecular thickness were quantified by means of novel 3-D methods. Structure model type was assessed by calculating the structure model index (SMI). The SMI was quantified based on a differential analysis of the triangulated bone surface of a structure. This technique allows quantification of structure model type, such as plate, rod objects, or mixture of plates or rods. Trabecular thickness is calculated directly from 3-D images, which is especially important for an a priori unknown or changing structure. Furthermore, 2-D trabecular thickness was also calculated based on the plate model. Our results showed that structure model type changed towards more rod-like in the elderly, and that trabecular thickness declined significantly with age. These changes become significant after 80 years of age for human tibial cancellous bone, whereas both properties seem to remain relatively unchanged between 20 and 80 years. Although a fairly close relationship was seen between 3-D trabecular thickness and 2-D trabecular thickness, real 3-D trabecular thickness was significantly underestimated using 2-D method.

Entities:  

Mesh:

Year:  2000        PMID: 10710004     DOI: 10.1016/s8756-3282(99)00281-1

Source DB:  PubMed          Journal:  Bone        ISSN: 1873-2763            Impact factor:   4.398


  60 in total

1.  The three-dimensional microstructure of the trabecular bone in the mandible.

Authors:  H S Moon; Y Y Won; K D Kim; A Ruprecht; H J Kim; H K Kook; M K Chung
Journal:  Surg Radiol Anat       Date:  2004-12       Impact factor: 1.246

2.  Do regional modifications in tissue mineral content and microscopic mineralization heterogeneity adapt trabecular bone tracts for habitual bending? Analysis in the context of trabecular architecture of deer calcanei.

Authors:  John G Skedros; Alex N Knight; Ryan W Farnsworth; Roy D Bloebaum
Journal:  J Anat       Date:  2012-01-06       Impact factor: 2.610

3.  Effects of a perfusion bioreactor activated novel bone substitute in spine fusion in sheep.

Authors:  Jesper Roed Sørensen; Kariatta Ester Koroma; Ming Ding; David Wendt; Stig Jespersen; Maria Vinther Juhl; Naseem Theilgaard; Ivan Martin; Søren Overgaard
Journal:  Eur Spine J       Date:  2012-07-10       Impact factor: 3.134

4.  Trabecular Plate Loss and Deteriorating Elastic Modulus of Femoral Trabecular Bone in Intertrochanteric Hip Fractures.

Authors:  Ji Wang; Bin Zhou; Ian Parkinson; C David L Thomas; John G Clement; Nick Fazzalari; X Edward Guo
Journal:  Bone Res       Date:  2013-12-31       Impact factor: 13.567

5.  Age-related changes in trabecular bone microstructures: global and local morphometry.

Authors:  M Stauber; R Müller
Journal:  Osteoporos Int       Date:  2005-12-31       Impact factor: 4.507

Review 6.  [New techniques for the diagnosis of osteoporosis].

Authors:  A S Issever; T M Link
Journal:  Radiologe       Date:  2006-10       Impact factor: 0.635

7.  Quantification of the roles of trabecular microarchitecture and trabecular type in determining the elastic modulus of human trabecular bone.

Authors:  Xiaowei S Liu; Paul Sajda; Punam K Saha; Felix W Wehrli; X Edward Guo
Journal:  J Bone Miner Res       Date:  2006-10       Impact factor: 6.741

8.  Complete volumetric decomposition of individual trabecular plates and rods and its morphological correlations with anisotropic elastic moduli in human trabecular bone.

Authors:  X Sherry Liu; Paul Sajda; Punam K Saha; Felix W Wehrli; Grant Bevill; Tony M Keaveny; X Edward Guo
Journal:  J Bone Miner Res       Date:  2008-02       Impact factor: 6.741

9.  Resolution dependence of the non-metric trabecular structure indices.

Authors:  Miki Sode; Andrew J Burghardt; Robert A Nissenson; Sharmila Majumdar
Journal:  Bone       Date:  2007-12-23       Impact factor: 4.398

10.  Micro-CT and mechanical evaluation of subchondral trabecular bone structure between postmenopausal women with osteoarthritis and osteoporosis.

Authors:  Z-M Zhang; Z-C Li; L-S Jiang; S-D Jiang; L-Y Dai
Journal:  Osteoporos Int       Date:  2009-09-22       Impact factor: 4.507

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.