Literature DB >> 10706473

Water characteristics associated with the occurrence of Legionella pneumophila in dental units.

F Zanetti1, S Stampi, G De Luca, P Fateh-Moghadam, M Antonietta, B Sabattini, L Checchi.   

Abstract

This study evaluated the incidence of Legionella pneumophila in dental unit water samples and investigated how the occurrence of these bacteria may be related to some physical, chemical and bacteriological characteristics of the water. The samples were taken from the incoming tap water, oral rinsing cup, air-water syringe, ultrasonic scaler, and the turbine of 23 dental units of private and public institutions. Apart from L. pneumophila (serogroup 1 and 3) isolated in 22 out of the 101 (21.8%) water samples tested, two other species were found: L. bozemanii and L. dumoffii. The highest densities and frequency of L. pneumophila were observed in the water coming into the units and in the dental units of public institutions. A negative association between L. pneumophila and 36 degrees C and 22 degrees C heterotrophic total plate counts and other gram-negative bacteria was found. An inverse association between the concentration of L. pneumophila and water temperature was also observed. The values of pH and total hardness did not show any significant difference in the L. pneumophila-positive and -negative dental unit waters. Finally, the chemical oxygen demand (COD) and residual chlorine were found to correlate positively with L. pneumophila.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10706473     DOI: 10.1034/j.1600-0722.2000.00763.x

Source DB:  PubMed          Journal:  Eur J Oral Sci        ISSN: 0909-8836            Impact factor:   2.612


  13 in total

1.  Microbial contamination of dental unit waterlines in Istanbul, Turkey.

Authors:  Duygu Göksay; Ayşin Cotuk; Zuhal Zeybek
Journal:  Environ Monit Assess       Date:  2008-01-22       Impact factor: 2.513

2.  Going with the flow: legionellosis risk in Toronto, Canada is strongly associated with local watershed hydrology.

Authors:  Victoria Ng; Patrick Tang; Frances Jamieson; Steven J Drews; Shirley Brown; Donald E Low; Caroline C Johnson; David N Fisman
Journal:  Ecohealth       Date:  2009-04-16       Impact factor: 3.184

3.  Assessment of Legionella pneumophila in recreational spring water with quantitative PCR (Taqman) assay.

Authors:  Shu-Min Shen; Ming-Yuan Chou; Bing-Mu Hsu; Wen-Tsai Ji; Tsui-Kang Hsu; Hsiu-Feng Tsai; Yu-Li Huang; Yi-Chou Chiu; Erl-Shyh Kao; Po-Min Kao; Cheng-Wei Fan
Journal:  Pathog Glob Health       Date:  2015-07-16       Impact factor: 2.894

4.  Utilization of polymerase chain reaction and selective media cultivation to identify Legionella in Taiwan spring water samples.

Authors:  Shih-Wei Huang; Bing-Mu Hsu; Chin-Chun Huang; Jung-Sheng Chen
Journal:  Environ Monit Assess       Date:  2010-04-28       Impact factor: 2.513

5.  Isolation and identification of Legionella and their host amoebae from weak alkaline carbonate spring water using a culture method combined with PCR.

Authors:  Shih-Wei Huang; Bing-Mu Hsu; Nai-Hsiung Chen; Chin-Chun Huang; Kuan-Hao Huang; Jung-Sheng Chen; Po-Min Kao
Journal:  Parasitol Res       Date:  2011-05-03       Impact factor: 2.289

6.  Identification and quantitative detection of Legionella spp. in various aquatic environments by real-time PCR assay.

Authors:  Po-Min Kao; Min-Che Tung; Bing-Mu Hsu; Yi-Chou Chiu; Cheng-Yu She; Shu-Min Shen; Yu-Li Huang; Wen-Chien Huang
Journal:  Environ Sci Pollut Res Int       Date:  2013-03-28       Impact factor: 4.223

7.  Investigation of the bacterial load and antibiotic susceptibility of dental units.

Authors:  Nihal Dogruöz Güngör; Duygu Göksay Kadaifçiler; Oya Öztan Peker
Journal:  Environ Monit Assess       Date:  2013-11-06       Impact factor: 2.513

8.  Comparison of the efficacies of disinfectants to control microbial contamination in dental unit water systems in general dental practices across the European Union.

Authors:  A J Schel; P D Marsh; D J Bradshaw; M Finney; M R Fulford; E Frandsen; E Østergaard; J M ten Cate; W R Moorer; A Mavridou; J J Kamma; G Mandilara; L Stösser; S Kneist; R Araujo; N Contreras; P Goroncy-Bermes; D O'Mullane; F Burke; P O'Reilly; G Hourigan; M O'Sullivan; R Holman; J T Walker
Journal:  Appl Environ Microbiol       Date:  2006-02       Impact factor: 4.792

9.  High prevalence, genetic diversity and intracellular growth ability of Legionella in hot spring environments.

Authors:  Tian Qin; Gebin Yan; Hongyu Ren; Haijian Zhou; Huanxin Wang; Ying Xu; Mingqiang Zhao; Hong Guan; Machao Li; Zhujun Shao
Journal:  PLoS One       Date:  2013-03-18       Impact factor: 3.240

10.  Legionella infection risk from domestic hot water.

Authors:  Paola Borella; M Teresa Montagna; Vincenzo Romano-Spica; Serena Stampi; Giovanna Stancanelli; Maria Triassi; Rachele Neglia; Isabella Marchesi; Guglielmina Fantuzzi; Daniela Tatò; Christian Napoli; Gianluigi Quaranta; Patrizia Laurenti; Erica Leoni; Giovanna De Luca; Cristina Ossi; Matteo Moro; Gabriella Ribera D'Alcalà
Journal:  Emerg Infect Dis       Date:  2004-03       Impact factor: 6.883

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.