Literature DB >> 10704547

Algorithm for interpreting the results of frequency doubling perimetry.

S C Patel1, D S Friedman, P Varadkar, A L Robin.   

Abstract

PURPOSE: To evaluate an algorithm for the identification of glaucomatous visual field defects with the screening mode of frequency doubling technology.
METHODS: Screening-mode frequency doubling technology and Swedish interactive threshold algorithm perimetry were performed on 137 of 150 consecutive patients referred to a glaucoma specialist. We created an algorithm for the frequency doubling technology that gave increased importance to both more severe defects and defects closer to fixation. These values were then compared with the results of the Swedish interactive threshold algorithm visual fields evaluated by the glaucoma hemifield test, two masked glaucoma specialists, and a published definition of glaucomatous damage to determine sensitivity and specificity of the frequency doubling technology screening mode for detecting glaucoma.

Entities:  

Mesh:

Year:  2000        PMID: 10704547     DOI: 10.1016/s0002-9394(99)00399-2

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  13 in total

1.  Clinical comparison of frequency doubling technology perimetry and Humphrey perimetry.

Authors:  R Casson; B James; A Rubinstein; H Ali
Journal:  Br J Ophthalmol       Date:  2001-03       Impact factor: 4.638

2.  The distribution of visual field defects per quadrant in standard automated perimetry as compared to frequency doubling technology perimetry.

Authors:  Wadih M Zein; Ziad F Bashshur; Rola F Jaafar; Baha' N Noureddin
Journal:  Int Ophthalmol       Date:  2010-10-06       Impact factor: 2.031

Review 3.  [Functional glaucoma diagnosis].

Authors:  C Erb; K Göbel
Journal:  Ophthalmologe       Date:  2009-04       Impact factor: 1.059

4.  Comparison of different methods of inter-eye asymmetry of rim area and disc area analysis.

Authors:  A A K Fansi; H Boisjoly; M Chagnon; P J Harasymowycz
Journal:  Eye (Lond)       Date:  2011-09-16       Impact factor: 3.775

5.  DTI parameters of axonal integrity and demyelination of the optic radiation correlate with glaucoma indices.

Authors:  Georg Michelson; Tobias Engelhorn; Simone Wärntges; Ahmed El Rafei; Joachim Hornegger; Arnd Doerfler
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-02-26       Impact factor: 3.117

6.  Frequency doubling technique perimetry and spectral domain optical coherence tomography in patients with early glaucoma.

Authors:  F K Horn; C Y Mardin; D Bendschneider; A G Jünemann; W Adler; R P Tornow
Journal:  Eye (Lond)       Date:  2010-11-19       Impact factor: 3.775

7.  Agreement between frequency doubling perimetry and static perimetry in eyes with high tension glaucoma and normal tension glaucoma.

Authors:  S Kogure; Y Toda; D Crabb; K Kashiwagi; F W Fitzke; S Tsukahara
Journal:  Br J Ophthalmol       Date:  2003-05       Impact factor: 4.638

8.  Structural and functional relationships in glaucoma using standard automated perimetry and the Humphrey Matrix.

Authors:  Seong Bae Park; Yoon Pyo Nam; Kyung Rim Sung; Michael S Kook
Journal:  Korean J Ophthalmol       Date:  2009-09-08

9.  The association of office intraocular pressure fluctuation in ocular hypertension with frequency doubling technology perimetry abnormality.

Authors:  Volkan Dayanir; Sayime Aydin; Pinar Okyay
Journal:  Int Ophthalmol       Date:  2007-10-16       Impact factor: 2.031

10.  Possible association between heavy computer users and glaucomatous visual field abnormalities: a cross sectional study in Japanese workers.

Authors:  Masayuki Tatemichi; Tadashi Nakano; Katsutoshi Tanaka; Takeshi Hayashi; Takeshi Nawa; Toshiaki Miyamoto; Hisanori Hiro; Minoru Sugita
Journal:  J Epidemiol Community Health       Date:  2004-12       Impact factor: 3.710

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.