| Literature DB >> 10699020 |
J C Aguilar1, M P Pérez-Breña, M L García, N Cruz, D D Erdman, J E Echevarría.
Abstract
We describe a multiplex reverse transcription-PCR (m-RT-PCR) assay that is able to detect and differentiate all known human parainfluenza viruses (HPIVs). Serial dilution experiments with reference strains that compared cell culture isolation and m-RT-PCR showed sensitivities ranging from 0.0004 50% tissue culture infective dose (TCID(50)) for HPIV type 4B (HPIV-4B) to 32 TCID(50)s for HPIV-3. As few as 10 plasmids containing HPIV PCR products could be detected in all cases. When 201 nasopharyngeal aspirate specimens from pediatric patients hospitalized for lower respiratory illness were tested, m-RT-PCR assay detected 64 HPIVs (24 HPIV-3, 23 HPIV-1, 10 HPIV-4, and 7 HPIV-2), while only 42 of them (21 HPIV-1, 14 HPIV-3, 6 HPIV-2, and 1 HPIV-4 isolates) grew in cell culture. Our m-RT-PCR assay was more sensitive than either cell culture isolation or indirect immunofluorescence with monoclonal antibodies for the detection of HPIV infections. Also, HPIV-4 was more frequently detected than HPIV-2 in this study, suggesting that it may have been underestimated as a lower respiratory tract pathogen because of the insensitivity of cell culture.Entities:
Mesh:
Substances:
Year: 2000 PMID: 10699020 PMCID: PMC86373 DOI: 10.1128/JCM.38.3.1191-1195.2000
Source DB: PubMed Journal: J Clin Microbiol ISSN: 0095-1137 Impact factor: 5.948