Literature DB >> 9253244

Protein digest analysis by pressurized capillary electrochromatography using an ion trap storage/reflectron time-of-flight mass detector.

J T Wu1, P Huang, M X Li, D M Lubman.   

Abstract

Pressurized capillary electrochromatography (pCEC) has been coupled to an ion trap storage/reflectron time-of-flight mass spectrometer for the analysis of peptide mixtures and protein digests. Taking advantage of the electroosmotic flow, high separation efficiency has been achieved in pCEC due to a relatively flat flow profile and the use of smaller packing materials. A supplementary pressure was used in these experiments which suppressed bubble formation and also allowed the tuning of the elution of peptides using the electrical field. In this work, a fast separation of a six-peptide mixture has been successfully performed. Using columns only 6 cm long, a tryptic digest of bovine cytochrome c was fully separated in around 14 min by properly tuning the applied voltage and the supplementary pressure. In addition, relatively complex protein digests, such as a tryptic digest of chicken ovalbumin, were analyzed using this pCEC/MS system, and more than 20 peaks were resolved in the total ion current chromatogram within 17 min. The use of an ion trap storage/reflectron time-of-flight mass spectrometer as an on-line detector further increased the resolving power of the pCEC by unambiguously identifying coeluting components. The nonscanning property of the time-of flight mass analyzer and the ion signal integration capability of the ion trap were successfully combined to provide rapid and sensitive full-mass range detection in these experiments.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9253244     DOI: 10.1021/ac970183g

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Development of a three-dimensional topographic map display for capillary electrophoresis/mass spectrometry with an ion trap/reflectron time-of-flight mass spectrometer detector: applications to tryptic digests of isoforms of myelin basic protein.

Authors:  M X Li; J T Wu; S Parus; D M Lubman
Journal:  J Am Soc Mass Spectrom       Date:  1998-07       Impact factor: 3.109

2.  Quantification of 5-methylcytosine and 5-hydroxymethylcytosine in genomic DNA from hepatocellular carcinoma tissues by capillary hydrophilic-interaction liquid chromatography/quadrupole TOF mass spectrometry.

Authors:  Ming-Luan Chen; Fan Shen; Wei Huang; Jia-Hui Qi; Yinsheng Wang; Yu-Qi Feng; Song-Mei Liu; Bi-Feng Yuan
Journal:  Clin Chem       Date:  2013-01-23       Impact factor: 8.327

Review 3.  David M. Lubman-The University of Michigan-A retrospective in research.

Authors:  David M Lubman
Journal:  Mass Spectrom Rev       Date:  2021-07-21       Impact factor: 10.946

4.  On-line capillary liquid chromatography tandem mass spectrometry on an ion trap/reflectron time-of-flight mass spectrometer using the sequence tag database search approach for peptide sequencing and protein identification.

Authors:  P Huang; D B Wall; S Parus; D M Lubman
Journal:  J Am Soc Mass Spectrom       Date:  2000-02       Impact factor: 3.262

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.