Literature DB >> 1068615

Bronchial brushing during fiberoptic bronchoscopy for the cytodiagnosis of lung cancer: comparison with sputum and bronchial washings.

C W Bedrossian, D L Rybka.   

Abstract

In a study of 50 cases of bronchogenic carcinoma in which brushings and washings during fiberoptic bronchoscopy, as well as sputum cytopathologic examinations were performed in the same patients, accuracy rates were respectively: 76 per cent, 76 per cent and 56 per cent. The main cytologic differences setting brush apart from wash and sputum specimens referred to the arrangement of tumor cells as well as the distribution of chromatin within their nuclei. These differences appeared related to cell degeneration which was minimal in brush materials and maximum in sputum specimens. Only six cases were assigned a different cell type of bronchogenic carcinoma when brush cytopathologic diagnoses were compared with results obtained by biopsy or lobectomy specimens. Our findings are consistent with the view that the brush technique is very accurate for the cytodiagnosis of lung cancer and becomes also rather specific once cytologic characteristics of the fresher samples obtained become familiar to the cytopathologist. Non-observance of the special characteristics of these better preserved cellular samples is the major pitfall as to diagnosing, cell typing and judging degree of differentiation of bronchogenic carcinoma in brush cytology specimens.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1068615

Source DB:  PubMed          Journal:  Acta Cytol        ISSN: 0001-5547            Impact factor:   2.319


  7 in total

1.  Predictive value of sputum cytology.

Authors:  J Benbassat; A Regev; P E Slater
Journal:  Thorax       Date:  1987-03       Impact factor: 9.139

2.  Disposable polythene catheter; an alternative to the brochial brushing method for cytology of bronchial secretions obtained with the fibreoptic bronchoscope.

Authors:  M J Cole; J Cowie; A I Spriggs
Journal:  J Clin Pathol       Date:  1978-09       Impact factor: 3.411

3.  Diagnostic accuracy of cytology and biopsy in primary bronchial carcinoma.

Authors:  C R Payne; P G Stovin; V Barker; S McVittie; J E Stark
Journal:  Thorax       Date:  1979-06       Impact factor: 9.139

4.  The value of sputum cytology.

Authors:  B MacDougall; B Weinerman
Journal:  J Gen Intern Med       Date:  1992 Jan-Feb       Impact factor: 5.128

5.  Accuracy of morphological diagnosis of lung cancer in a department of respiratory medicine.

Authors:  M D Clee; H L Duguid; D J Sinclair
Journal:  J Clin Pathol       Date:  1982-04       Impact factor: 3.411

6.  Detection of lung cancer using MAGE A1-6 and SSX4 RT-PCR expression profiles in the bronchial wash fluid.

Authors:  Kwan-Ho Lee; Kyung-Chul Shin; Chae-Hun Lee; Sang-Hoon Jheon; Chang-Ho Jeon
Journal:  Cancer Res Treat       Date:  2007-06-30       Impact factor: 4.679

7.  Utility of Various Bronchoscopic Modalities in Lung Cancer Diagnosis

Authors:  Vishak Acharya K; Unnikrishnan B; Archana Shenoy; Ramesh Holla
Journal:  Asian Pac J Cancer Prev       Date:  2017-07-27
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.