Literature DB >> 10682927

Accuracy of stereotactic coordinate transformation using a localisation frame and computed tomographic imaging. Part II. Analysis of matrix-based coordinate transformation.

P Grunert1.   

Abstract

The accuracy of coordinate transformation from a CT image to a stereotactic frame was investigated for stereotactic systems using a localisation frame and matrix-based coordinate transformation. The main source of error influencing calculation was input data, due to inaccurate calculation of the centres of the rods of the localisation frame in the CT image, and the propagation of this input error during subsequent matrix calculation. Systemic errors during matrix calculation do not exist, and rounding off errors were of subordinate importance compared to the input data error. The influence of input data error on coordinate transformation was studied by geometric methods, computer simulation, and numerical analysis. In the geometric model, input data errors affected the calculation of the centres of the three oblique rods in the frame space and shifted them three points upwards or downwards on the axis of each rod. The three centres of the oblique rods defined the "CT plane" in the 3D space of the stereotactic frame. Displacements of these three centres caused a characteristic tilting of the CT plane. The positions of the correct and tilted CT planes defined the spatial error properties for all target points on the CT plane. The computer simulation investigated the effects on matrix-based transformation of all possible displacement combinations on the three oblique rods by 1 pixel (1. 16 mm) in the x and y directions. A characteristic, space-dependent distribution of the frame-related coordinates was obtained for each target point. In the centre of the frame, we found a maximal deviation of 1.0 mm in the xy direction and 2 mm in the z direction. This corresponded to an error amplification of 0.73 in the xy direction and 1.22 in the z direction relative to the error at the centres of the rods. The maximum deviation (found in the periphery) for all combinations on the three oblique rods was 1.7 mm in the xy direction and 3.3 mm in the z direction. This resulted in an amplification of 1.03 in the xy direction and 2.01 in the z direction. This results had to be multiplied by 2 to obtain a maximal error estimate for displacements including all nine rods of the localisation frame. Numerical analysis showed stable solutions with low error amplification for hexagonal frame arrangements.

Mesh:

Year:  1999        PMID: 10682927     DOI: 10.1007/s101430050015

Source DB:  PubMed          Journal:  Neurosurg Rev        ISSN: 0344-5607            Impact factor:   3.042


  7 in total

Review 1.  Computer-aided navigation in neurosurgery.

Authors:  P Grunert; K Darabi; J Espinosa; R Filippi
Journal:  Neurosurg Rev       Date:  2003-05       Impact factor: 3.042

2.  The evolution of stereotactic guidance in neuroendoscopy.

Authors:  Wuttipong Tirakotai; Oliver Bozinov; Ulrich Sure; Thomas Riegel; Helmut Bertalanffy; Dieter Hellwig
Journal:  Childs Nerv Syst       Date:  2004-07-17       Impact factor: 1.475

3.  Stereotactic Localization: From Single-Slice to Multi-Slice Registration Including a Novel Solution for Parallel Bipanels.

Authors:  Mark Sedrak; Andres E Bruna; Armando L Alaminos-Bouza
Journal:  Cureus       Date:  2022-03-17

4.  Novel Geometries for Stereotactic Localizers.

Authors:  Mark Sedrak; Andres Bruna; Armando L Alaminos-Bouza; Russell A Brown
Journal:  Cureus       Date:  2021-06-13

5.  An error analysis perspective for patient alignment systems.

Authors:  Michael Figl; Marcus Kaar; Rainer Hoffman; Alfred Kratochwil; Johann Hummel
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-03-06       Impact factor: 2.924

6.  The V-Localizer for Stereotactic Guidance.

Authors:  Russell A Brown; Armando L Alaminos-Bouza; Andres E Bruna; Mark Sedrak
Journal:  Cureus       Date:  2021-07-21

7.  Zero Setup Margin Mask versus Frame Immobilization during Gamma Knife® Icon™ Stereotactic Radiosurgery for Brain Metastases.

Authors:  Tugce Kutuk; Rupesh Kotecha; Ranjini Tolakanahalli; D Jay J Wieczorek; Yongsook C Lee; Manmeet S Ahluwalia; Matthew D Hall; Michael W McDermott; Haley Appel; Alonso N Gutierrez; Minesh P Mehta; Martin C Tom
Journal:  Cancers (Basel)       Date:  2022-07-13       Impact factor: 6.575

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.