Literature DB >> 10661588

Towards the elimination of Monte Carlo statistical fluctuation from dose volume histograms for radiotherapy treatment planning.

J Sempau1, A F Bielajew.   

Abstract

The Monte Carlo calculation of dose for radiotherapy treatment planning purposes introduces unavoidable statistical noise into the prediction of dose in a given volume element (voxel). When the doses in these voxels are summed to produce dose volume histograms (DVHs), this noise translates into a broadening of differential DVHs and correspondingly flatter DVHs. A brute force approach would entail calculating dose for long periods of time--enough to ensure that the DVHs had converged. In this paper we introduce an approach for deconvolving the statistical noise from DVHs, thereby obtaining estimates for converged DVHs obtained about 100 times faster than the brute force approach described above. There are two important implications of this work: (a) decisions based upon DVHs may be made much more economically using the new approach and (b) inverse treatment planning or optimization methods may employ Monte Carlo dose calculations at all stages of the iterative procedure since the prohibitive cost of Monte Carlo calculations at the intermediate calculation steps can be practically eliminated.

Mesh:

Year:  2000        PMID: 10661588     DOI: 10.1088/0031-9155/45/1/310

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  5 in total

1.  A framework for implementation of organ effect models in TOPAS with benchmarks extended to proton therapy.

Authors:  J Ramos-Méndez; J Perl; J Schümann; J Shin; H Paganetti; B Faddegon
Journal:  Phys Med Biol       Date:  2015-06-10       Impact factor: 3.609

2.  Concurrent Monte Carlo transport and fluence optimization with fluence adjusting scalable transport Monte Carlo.

Authors:  Y M Yang; M Svatos; C Zankowski; B Bednarz
Journal:  Med Phys       Date:  2016-06       Impact factor: 4.071

3.  The effect of statistical noise on IMRT plan quality and convergence for MC-based and MC-correction-based optimized treatment plans.

Authors:  Jeffrey V Siebers
Journal:  J Phys Conf Ser       Date:  2008-04-04

4.  Maintaining dosimetric quality when switching to a Monte Carlo dose engine for head and neck volumetric-modulated arc therapy planning.

Authors:  Vladimir Feygelman; Kujtim Latifi; Mark Bowers; Kevin Greco; Eduardo G Moros; Max Isacson; Agnes Angerud; Jimmy Caudell
Journal:  J Appl Clin Med Phys       Date:  2022-02-25       Impact factor: 2.243

5.  Recommended dose voxel size and statistical uncertainty parameters for precision of Monte Carlo dose calculation in stereotactic radiotherapy.

Authors:  Simon K Goodall; Martin A Ebert
Journal:  J Appl Clin Med Phys       Date:  2020-10-30       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.