Electron contamination from the lead cutout used in kilovoltage radiotherapy.

C H Lee1, K K Chan.   

Abstract

In kilovoltage radiotherapy, low-energy electrons are generated on the lead cutout plate frequently used to shape the x-ray field. They can cause surface dose enhancement and affect the percentage depth dose (PDD) and cutout factor when these parameters are measured with a parallel plate chamber. Although many previous studies concerning a similar surface dose enhancement have suggested using a thin electron filter to eliminate the effect of these low-energy electrons, no details have been given regarding the adequacy of the filter. This paper describes the procedures required to test an electron filter for our Darpec 2000 superficial x-ray machine. A piece of plain paper was found to be an adequate electron filter, which could block all the low-energy electrons without affecting the PDD and cutout factor measurement. The surface dose enhancement caused by the presence of the cutout plate was studied with such a filter. The enhancement was found to increase with x-ray energy and decrease with cutout size as well as applicator size. At the highest x-ray energy in this study (120 kV, HVL 8.6 mmAl), the enhancement ranges from less than 1% for a 8 cm diameter cutout to a maximum of 14% for a 2 cm diameter cutout with a 10 cm applicator. For a 5 cm diameter applicator it ranges from about 1% to about 11%. The difference between the measured and predicted cutout factor displays similar characteristics. Since the low-energy electrons do not generate any useful treatment dose but their presence can lead to potential dosimetry problems, we suggest that a filter tested with the procedure described in this paper should be used when percentage depth dose and cutout factor for kilovoltage x-ray are measured with a parallel-plate chamber.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10661579     DOI: 10.1088/0031-9155/45/1/301

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  4 in total

1.  Acceptance, commissioning and clinical use of the WOmed T-200 kilovoltage X-ray therapy unit.

Authors:  Maria M Aspradakis; Paolo Zucchetti
Journal:  Br J Radiol       Date:  2015-07-30       Impact factor: 3.039

2.  Verification of the machine delivery parameters of a treatment plan via deep learning.

Authors:  Jiawei Fan; Lei Xing; Ming Ma; Weigang Hu; Yong Yang
Journal:  Phys Med Biol       Date:  2020-09-30       Impact factor: 3.609

3.  Verification of IMRT dose calculations using AAA and PBC algorithms in dose buildup regions.

Authors:  Arun S Oinam; Lakhwant Singh
Journal:  J Appl Clin Med Phys       Date:  2010-08-26       Impact factor: 2.102

4.  Assessment of the accuracy of dose calculation in the build-up region of the tangential field of the breast for a radiotherapy treatment planning system.

Authors:  Bagher Farhood; Mohammad Taghi Bahreyni Toossi; Shokouhozaman Soleymanifard; Tohid Mortezazadeh
Journal:  Contemp Oncol (Pozn)       Date:  2017-09-29
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.