Literature DB >> 10659763

Improved spatial resolution by MOSFET dosimetry of an x-ray microbeam.

G I Kaplan1, A B Rosenfeld, B J Allen, J T Booth, M G Carolan, A Holmes-Siedle.   

Abstract

Measurement of the lateral profile of the dose distribution across a narrow x-ray microbeam requires a dosimeter with a micron resolution. We investigated the use of a MOSFET dosimeter in an "edge-on" orientation with the gate insulating oxide layer parallel to the direction of the beam. We compared results using this technique to Gafchromic film measurements of a 200 micrometer wide planar x-ray microbeam. The microbeam was obtained by using a vernier micrometer-driven miniature collimator attached to a Therapax DXT300 x-ray machine operated at 100 kVp. The "edge-on" application allows utilization of the ultra thin sensitive volume of the MOSFET detector. Spatial resolution of both the MOSFET and Gafchromic film dosimeters appeared to be of about 1 micrometer. The MOSFET dosimeter appeared to provide more uniform dose profiles with the advantage of on-line measurements.

Entities:  

Mesh:

Year:  2000        PMID: 10659763     DOI: 10.1118/1.598866

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  5 in total

1.  Fiber-optic detector for real time dosimetry of a micro-planar x-ray beam.

Authors:  Matthew D Belley; Ian N Stanton; Mike Hadsell; Rachel Ger; Brian W Langloss; Jianping Lu; Otto Zhou; Sha X Chang; Michael J Therien; Terry T Yoshizumi
Journal:  Med Phys       Date:  2015-04       Impact factor: 4.071

2.  Assessment of female breast dose for thoracic cone-beam CT using MOSFET dosimeters.

Authors:  Wenzhao Sun; Bin Wang; Bo Qiu; Jian Liang; Weihao Xie; Xiaowu Deng; Zhenyu Qi
Journal:  Oncotarget       Date:  2017-03-21

Review 3.  Microbeam radiation therapy - grid therapy and beyond: a clinical perspective.

Authors:  Elisabeth Schültke; Jacques Balosso; Thomas Breslin; Guido Cavaletti; Valentin Djonov; Francois Esteve; Michael Grotzer; Guido Hildebrandt; Alexander Valdman; Jean Laissue
Journal:  Br J Radiol       Date:  2017-07-27       Impact factor: 3.039

4.  Passive radiofrequency x-ray dosimeter tag based on flexible radiation-sensitive oxide field-effect transistor.

Authors:  Tobias Cramer; Ilaria Fratelli; Pedro Barquinha; Ana Santa; Cristina Fernandes; Franck D'Annunzio; Christophe Loussert; Rodrigo Martins; Elvira Fortunato; Beatrice Fraboni
Journal:  Sci Adv       Date:  2018-06-29       Impact factor: 14.136

5.  Evaluation of a pixelated large format CMOS sensor for x-ray microbeam radiotherapy.

Authors:  Samuel Flynn; Tony Price; Philip P Allport; Ileana Silvestre Patallo; Russell Thomas; Anna Subiel; Stefan Bartzsch; Franziska Treibel; Mabroor Ahmed; Jon Jacobs-Headspith; Tim Edwards; Isaac Jones; Dan Cathie; Nicola Guerrini; Iain Sedgwick
Journal:  Med Phys       Date:  2020-01-06       Impact factor: 4.071

  5 in total