Cyanoacrylate glue as an alternative to an additional suture line in the repair of type A aortic dissection.

R De Paulis1, S L Matteucci, A Penta de Peppo, L Chiariello.   

Abstract

We describe the use of cyanoacrylate glue in conjunction with gelatin-resorcinol-formalin glue for the treatment of type A aortic dissection. Instead of placing an additional suture line 2-3 cm from the edges of the aortic stumps to create a large pocket for gluing, we have been using a cyanoacrylate adhesive for approximating the walls of the true and false lumina without the risk of tearing them. Moreover, the simplicity and quickness of the procedure enables application of the cyanoacrylate glue even deeper into the aortic arch, creating a wider area for gluing the dissected layers.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10653255      PMCID: PMC325663     

Source DB:  PubMed          Journal:  Tex Heart Inst J        ISSN: 0730-2347


  6 in total

1.  Surgical clip for compression of the aortic wall during gluing.

Authors:  T Sakamoto; H Arai; M Sunamori
Journal:  Ann Thorac Surg       Date:  1997-10       Impact factor: 4.330

2.  Aortic valve conservation in acute type A dissection.

Authors:  S Westaby; T Katsumata; E Freitas
Journal:  Ann Thorac Surg       Date:  1997-10       Impact factor: 4.330

3.  Efficient tissue gluing in aortic dissection.

Authors:  H G Borst; J Laas; B Bühner
Journal:  Eur J Cardiothorac Surg       Date:  1994       Impact factor: 4.191

4.  Use of biological glue in acute aortic dissection. Preliminary clinical results with a new surgical technique.

Authors:  D Guilmet; J Bachet; B Goudot; C Laurian; F Gigou; O Bical; M Barbagelatta
Journal:  J Thorac Cardiovasc Surg       Date:  1979-04       Impact factor: 5.209

5.  Surgical treatment of acute type A dissecting aneurysm, with preservation of the native aortic valve and use of biologic glue. Follow-up to 6 years.

Authors:  E E Weinschelbaum; C Schamun; V Caramutti; H Tacchi; J Cors; R G Favaloro
Journal:  J Thorac Cardiovasc Surg       Date:  1992-02       Impact factor: 5.209

6.  Surgery of type A acute aortic dissection with Gelatine-Resorcine-Formol biological glue: a twelve-year experience.

Authors:  J Bachet; B Goudot; G Teodori; D Brodaty; C Dubois; P De Lentdecker; D Guilmet
Journal:  J Cardiovasc Surg (Torino)       Date:  1990 May-Jun       Impact factor: 1.888

  6 in total
  1 in total

1.  Effectiveness of a new inflatable balloon device for gluing dissected layers in an experimental model of aortic dissection.

Authors:  Necmettin Colak; Yunus Nazli; Mehmet Fatih Alpay; Ismail Olgun Akkaya; Omer Nuri Aksoy; Sukran Akgedik; Omer Cakir
Journal:  Exp Clin Cardiol       Date:  2013
  1 in total