Literature DB >> 10646148

Accuracy and accommodation capability of a handheld autorefractor.

W Wesemann1, B Dick.   

Abstract

PURPOSE: To determine the accuracy of measurement by the Nikon Retinomax handheld autorefractor and its ability to relax accommodation.
SETTING: Pediatric Section, Department of Ophthalmology, University of Mainz, Germany.
METHODS: To perform a series of comparative measurements, autorefractor readings were obtained on healthy young adults (students) and on children aged 2 to 12 years. The autorefractor readings were compared with subjective refractions of the young adults and with cycloplegic retinoscopy of the children.
RESULTS: In adults, the accuracy of the handheld autorefractor measurements was comparable to that of conventional tabletop autorefractors. In children, the autorefractor measurements performed under cycloplegia were reliable; when cycloplegic agents were not administered, 24% were overcorrected by more than -2.0 diopters.
CONCLUSION: Cycloplegia is often necessary to obtain accurate autorefractor results.

Entities:  

Mesh:

Year:  2000        PMID: 10646148     DOI: 10.1016/s0886-3350(99)00325-9

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  22 in total

1.  Non-cycloplegic screening for amblyopia via refractive findings with the Nikon Retinomax hand held autorefractor in 3 year old kindergarten children.

Authors:  J C Barry; H H König
Journal:  Br J Ophthalmol       Date:  2001-10       Impact factor: 4.638

2.  Comparison of the Retinomax and Palm-AR Auto-Refractors: a pilot study.

Authors:  Elise Ciner; Ashanti Carter; Gui-Shuang Ying; Maureen Maguire; Marjean Taylor Kulp
Journal:  Optom Vis Sci       Date:  2011-07       Impact factor: 1.973

3.  [Examination of preschool children for refractive errors. First experience using a handheld autorefractor].

Authors:  T F Büchner; U Schnorbus; U H Grenzebach; T Stupp; H Busse
Journal:  Ophthalmologe       Date:  2003-11       Impact factor: 1.059

4.  Pterygium in Indonesia: prevalence, severity and risk factors.

Authors:  G Gazzard; S-M Saw; M Farook; D Koh; D Widjaja; S-E Chia; C-Y Hong; D T H Tan
Journal:  Br J Ophthalmol       Date:  2002-12       Impact factor: 4.638

5.  Non-cycloplegic spherical equivalent refraction in adults: comparison of the double-pass system, retinoscopy, subjective refraction and a table-mounted autorefractor.

Authors:  Meritxell Vilaseca; Montserrat Arjona; Jaume Pujol; Elvira Peris; Vanessa Martínez
Journal:  Int J Ophthalmol       Date:  2013-10-18       Impact factor: 1.779

6.  Comparison of photorefraction, autorefractometry and retinoscopy in children.

Authors:  Goktug Demirci; Banu Arslan; Mustafa Özsütçü; Mustafa Eliaçık; Gokhan Gulkilik
Journal:  Int Ophthalmol       Date:  2013-10-10       Impact factor: 2.031

7.  Study on accommodation by autorefraction and dynamic refraction in children.

Authors:  Prabhakar Srinivasapur Krishnacharya
Journal:  J Optom       Date:  2014-08-15

8.  Accuracy of noncycloplegic retinoscopy, retinomax autorefractor, and SureSight vision screener for detecting significant refractive errors.

Authors:  Marjean Taylor Kulp; Gui-Shuang Ying; Jiayan Huang; Maureen Maguire; Graham Quinn; Elise B Ciner; Lynn A Cyert; Deborah A Orel-Bixler; Bruce D Moore
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-03-06       Impact factor: 4.799

9.  Treating uncorrected refractive error in adults in the developing world with autorefractors and ready-made spectacles.

Authors:  Thomas S Shane; O'Rese Knight; Wei Shi; Joyce C Schiffman; Eduardo C Alfonso; Richard K Lee
Journal:  Clin Exp Ophthalmol       Date:  2011-04-21       Impact factor: 4.207

10.  Accuracy of a new photo-refractometer in young and adult patients.

Authors:  Thilo Schimitzek; Wolf A Lagrèze
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2005-01-14       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.