Literature DB >> 10642470

Comparison of three different plating techniques for the dorsum of the distal radius: a biomechanical study.

R Peine1, D A Rikli, R Hoffmann, G Duda, P Regazzoni.   

Abstract

Three different plating techniques were used on experimentally produced dorsally displaced distal radius fractures in cadavers and were tested in 4-point bending: a AO 3.5-mm T plate (group 1), two 2. 0-mm titanium plates 60 degrees to each other (group 2), and the AO pi plate (group 3). A metaphyseal defect was simulated by a dorsally open wedge osteotomy. The tests show that the 2-mm double-plating technique has superior stiffness and statistically equivalent bending and bone gap to failure compared with the AO 3.5-mm T plate or the pi plate when applied to the unstable distal radius fracture model. (J Hand Surg 2000; 25A:29-33. Copyright 2000 by the American Society for Surgery of the Hand.).

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10642470     DOI: 10.1053/jhsu.2000.jhsu025a0029

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  17 in total

1.  The effects of screw length on stability of simulated osteoporotic distal radius fractures fixed with volar locking plates.

Authors:  Lindley B Wall; Michael D Brodt; Matthew J Silva; Martin I Boyer; Ryan P Calfee
Journal:  J Hand Surg Am       Date:  2012-02-02       Impact factor: 2.230

2.  Buttressing angle of the double-plating fixation of a distal radius fracture: a finite element study.

Authors:  Chun-Li Lin; Yu-Hao Lin; Alvin Chao-Yu Chen
Journal:  Med Biol Eng Comput       Date:  2006-07-11       Impact factor: 2.602

Review 3.  Treatment of distal radius fractures with locking plates: an update.

Authors:  Francois Loisel; Hugo Kielwasser; Grégoire Faivre; Thomas Rondot; Séverin Rochet; Antoine Adam; Pauline Sergent; Grégoire Leclerc; Laurent Obert; Daniel Lepage
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-07-12

4.  Citation analysis of the 100 most common articles regarding distal radius fractures.

Authors:  Richard Jones; Travis Hughes; Kevin Lawson; Gregory DeSilva
Journal:  J Clin Orthop Trauma       Date:  2016-11-16

5.  [The osteosynthesis of fractures of distal radius with the AO/ASIF Titanium Pi Plate].

Authors:  U Zingg; P Rillmann; U Metzger; A Platz
Journal:  Unfallchirurg       Date:  2005-03       Impact factor: 1.000

6.  Complications of Radial Column Plating of the Distal Radius.

Authors:  Samuel E Galle; Neil G Harness; Jacques H Hacquebord; Raoul J Burchette; Brett Peterson
Journal:  Hand (N Y)       Date:  2018-02-27

7.  Type C distal radial fractures treated with conventional AO plates: an easy and cost-saving solution in a locking plate era.

Authors:  Bas Twigt; Michael Bemelman; Koen Lansink; Loek Leenen
Journal:  Int Orthop       Date:  2013-01-11       Impact factor: 3.075

8.  Biomechanical stability of four fixation constructs for distal radius fractures.

Authors:  John T Capo; Tosca Kinchelow; Kenneth Brooks; Virak Tan; Michaele Manigrasso; Kristin Francisco
Journal:  Hand (N Y)       Date:  2009-02-05

9.  Different osteosyntheses for Colles' fracture: a mechanical study in 42 cadaver bones.

Authors:  Yngvar Krukhaug; Nils R Gjerdet; Odd J Lundberg; Peer K Lilleng; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

10.  Assessment of a novel biomechanical fracture model for distal radius fractures.

Authors:  Sebastian Felix Baumbach; Enrico Dall'Ara; Patrick Weninger; Anna Antoni; Hannes Traxler; Martin Dörr; Philippe K Zysset
Journal:  BMC Musculoskelet Disord       Date:  2012-12-18       Impact factor: 2.362

View more