Literature DB >> 10639199

Ventilation inhomogeneity assessed by nitrogen washout and ventilation-perfusion mismatch by capnography in stable and induced airway obstruction.

N O Strömberg1, P M Gustafsson.   

Abstract

Few studies have been published on gas distribution in the lung during acute and stable airway obstruction in children. Multiple breath nitrogen (N(2)) washout is an established method for assessing ventilation inhomogeneity, while the tidal breathing capnogram may be used as an indicator of ventilation-perfusion (V(')(A)/Q) mismatch. We hypothesized that significant V(')(A)/Q mismatch is not seen in stable airway obstruction unless obstruction is severe, and that stable and induced airway obstruction of similar severity would result in different degrees of V(')(A)/Q mismatch. To test this hypothesis, we performed spirometry measurements of forced expiratory volume in 1 sec (FEV(1)), multiple breath N(2) washout, and tidal breathing capnography in 11 young patients (9-30 years) with cystic fibrosis, 37 asthmatic patients (8-18 years), and 34 healthy subjects (7-20 years). Lung function was measured at rest, after airway obstruction induced by cold dry air hyperventilation or methacholine challenge, and after beta(2)-agonist treatment. V(')(A)/Q mismatch was assessed from the slopes of the phases II and III of the capnogram. We observed a normal capnogram during stable obstruction of moderate severity despite significant ventilation inhomogeneity. In patients with severe stable obstruction and in those with induced airway obstruction significant ventilation inhomogeneity and pathological capnograms were seen. Induced airway obstruction, resulted in a more pathological capnogram than stable obstruction of similar severity. beta(2)-agonist treatment reduced ventilation inhomogeneity, but did not improve the capnogram. Our findings are compatible with the presence of an efficient pulmonary blood flow regulatory mechanism that adequately compensates for chronic ventilation inhomogeneity of moderate severity, but not for severe or sudden airway obstruction. Copyright 2000 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2000        PMID: 10639199     DOI: 10.1002/(sici)1099-0496(200002)29:2<94::aid-ppul3>3.0.co;2-b

Source DB:  PubMed          Journal:  Pediatr Pulmonol        ISSN: 1099-0496


  12 in total

Review 1.  Pharmacologic management of the hospitalized pediatric asthma patient.

Authors:  K A Hardin; H J Kallas; R J McDonald
Journal:  Clin Rev Allergy Immunol       Date:  2001-06       Impact factor: 8.667

Review 2.  The critically ill asthmatic--from ICU to discharge.

Authors:  Samuel Louie; Brian M Morrissey; Nicholas J Kenyon; Timothy E Albertson; Mark Avdalovic
Journal:  Clin Rev Allergy Immunol       Date:  2012-08       Impact factor: 8.667

3.  The effects of cardiac output and pulmonary arterial hypertension on volumetric capnography derived-variables during normoxia and hypoxia.

Authors:  Martina Mosing; Annette P N Kutter; Samuel Iff; Joanna Raszplewicz; Jacqueline Mauch; Stephan H Bohm; Gerardo Tusman
Journal:  J Clin Monit Comput       Date:  2014-06-08       Impact factor: 2.502

4.  Eyes Wide Shut: Improving Physiologic Monitoring During Mechanical Ventilation.

Authors:  Allan Doctor
Journal:  Pediatr Crit Care Med       Date:  2016-12       Impact factor: 3.624

5.  Capnogram slope and ventilation dead space parameters: comparison of mainstream and sidestream techniques.

Authors:  A L Balogh; F Petak; G H Fodor; J Tolnai; Z Csorba; B Babik
Journal:  Br J Anaesth       Date:  2016-07       Impact factor: 9.166

6.  A novel application of capnography during controlled human exposure to air pollution.

Authors:  Karl Z Lukic; Bruce Urch; Michael Fila; Marie E Faughnan; Frances Silverman
Journal:  Biomed Eng Online       Date:  2006-10-18       Impact factor: 2.819

7.  Novel volumetric capnography indices measure ventilation inhomogeneity in cystic fibrosis.

Authors:  Sotirios Fouzas; Anne-Christianne Kentgens; Olga Lagiou; Bettina Sarah Frauchiger; Florian Wyler; Ilias Theodorakopoulos; Sophie Yammine; Philipp Latzin
Journal:  ERJ Open Res       Date:  2022-03-14

8.  Effects of respiratory mechanics on the capnogram phases: importance of dynamic compliance of the respiratory system.

Authors:  Barna Babik; Zsófia Csorba; Dorottya Czövek; Patrick N Mayr; Gábor Bogáts; Ferenc Peták
Journal:  Crit Care       Date:  2012-10-02       Impact factor: 9.097

9.  Methacholine-Induced Variations in Airway Volume and the Slope of the Alveolar Capnogram Are Distinctly Associated with Airflow Limitation and Airway Closure.

Authors:  Laurent Plantier; Sylvain Marchand-Adam; Laurent Boyer; Camille Taillé; Christophe Delclaux
Journal:  PLoS One       Date:  2015-11-23       Impact factor: 3.240

10.  End-expiratory lung volume remains stable during N2 MBW in healthy sleeping infants.

Authors:  Per M Gustafsson; Laszlo Kadar; Sanna Kjellberg; Lena Andersson; Anders Lindblad; Paul D Robinson
Journal:  Physiol Rep       Date:  2020-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.