Dosimetry techniques for narrow proton beam radiosurgery.

S M Vatnitsky1, D W Miller, M F Moyers, R P Levy, R W Schulte, J D Slater, J M Slater.   

Abstract

Characterization of narrow beams used in proton stereotactic radiosurgery (PSRS) requires special efforts, since the use of finite size detectors can lead to distortion of the measured dose distributions. Central axis depth doses, lateral profiles and field size dependence factors are the most important beam characteristics to be determined prior to dosimetry calculations and beam modelling for PSRS. In this paper we report recommendations for practical dosimetry techniques which were developed from a comparison of beam characteristics determined with a variety of radiation detectors for 126 and 155 MeV narrow proton beams shaped with 2-30 mm circular brass collimators. These detectors included small-volume ionization chambers, a diamond detector, an Hi-p Si diode, TLD cubes, radiographic and radiochromic films. We found that both types of film are suitable for profile measurements in narrow beams. Good agreement between depth dose distributions measured with ionization chambers, diamond and diode detectors was demonstrated in beams with diameters of 20-30 mm. The diode detector can be used in smaller beams, down to 5 mm diameter. For beams with diameters less than 5 mm, reliable depth dose data may be obtained only with radiochromic film. The tested ionization chambers are appropriate for calibration of beams with diameters of 20-30 mm. TLD cubes and diamond detectors are useful to determine relative dose in beams with diameters of 10-20 mm. Field size factors for smaller beams should be obtained with diode and radiochromic film. We conclude that dosimetry characterization of proton beams down to several millimetres in diameter can be performed using the described procedures.

Entities:  

Mesh:

Year:  1999        PMID: 10588285     DOI: 10.1088/0031-9155/44/11/308

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  6 in total

1.  Range and modulation dependencies for proton beam dose per monitor unit calculations.

Authors:  Wen C Hsi; Andries N Schreuder; Michael F Moyers; Chris E Allgower; Jonathan B Farr; Anthony E Mascia
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

2.  Quality assurance evaluation of spot scanning beam proton therapy with an anthropomorphic prostate phantom.

Authors:  K Iqbal; M Gillin; P A Summers; S Dhanesar; K A Gifford; S A Buzdar
Journal:  Br J Radiol       Date:  2013-09-18       Impact factor: 3.039

Review 3.  The physics of proton therapy.

Authors:  Wayne D Newhauser; Rui Zhang
Journal:  Phys Med Biol       Date:  2015-03-24       Impact factor: 3.609

4.  Initial testing of a pixelated silicon detector prototype in proton therapy.

Authors:  Andrew J Wroe; Grant McAuley; Anthony V Teran; Jeannie Wong; Marco Petasecca; Michael Lerch; James M Slater; Anatoly B Rozenfeld
Journal:  J Appl Clin Med Phys       Date:  2017-07-18       Impact factor: 2.102

5.  Evaluation of the dosimetric properties of a diode detector for small field proton radiosurgery.

Authors:  Grant A McAuley; Anthony V Teran; Jerry D Slater; James M Slater; Andrew J Wroe
Journal:  J Appl Clin Med Phys       Date:  2015-11-08       Impact factor: 2.102

6.  Dosimetric Characteristics of a Two-Dimensional Diode Array Detector Irradiated with Passively Scattered Proton Beams.

Authors:  Praimakorn Liengsawangwong; Nanayan Sahoo; Xiaoning Ding; MingFwu Lii; Michale T Gillin; Xiaorong Ronald Zhu
Journal:  Cancers (Basel)       Date:  2015-07-30       Impact factor: 6.639

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.