Literature DB >> 10586466

Correction of cervical kyphosis using pedicle screw fixation systems.

K Abumi1, Y Shono, H Taneichi, M Ito, K Kaneda.   

Abstract

STUDY
DESIGN: This retrospective study was conducted to analyze the clinical results in 30 patients with cervical kyphosis that had been treated using cervical pedicle screw fixation systems.
OBJECTIVES: To evaluate the effectiveness of a pedicle screw fixation procedure in correction of cervical kyphosis. SUMMARY OF BACKGROUND DATA: Correction of cervical kyphosis is a challenging problem in the field of spinal surgery. There have been several reports regarding surgical correction of cervical kyphosis; however, there have been no detailed reports on correction of cervical kyphosis using a pedicle screw fixation procedure.
METHODS: Thirty patients with cervical kyphosis underwent correction and fusion using cervical pedicle screw fixation. Seventeen of 30 patients with flexible kyphosis (Group I) were managed by a posterior procedure alone. The remaining 13 patients with rigid or fixed kyphosis (Group II) had a combined anterior and posterior procedure.
RESULTS: The average preoperative cervical kyphosis of 29.4 degrees improved to 2.3 degrees after surgery and was 2.8 degrees at the final follow-up. In Group I patients, preoperative kyphosis of 28.4 degrees improved to 5.1 degrees at the final follow-up. In contrast, preoperative kyphosis of 30.8 degrees in Group II patients improved to 0.5 degree at the final follow-up. Solid fusion was achieved in all patients. There were two patients with transient nerve root complications related to pedicle screw instrumentation.
CONCLUSION: Cervical kyphosis in 30 patients was effectively corrected using a pedicle screw fixation procedure with no serious complications. Flexible kyphosis with segmental motion can be satisfactorily corrected by a single posterior procedure using pedicle screw fixation. However, circumferential osteotomies combined with a posterior shortening procedure involving a pedicle screw system are required to achieve the best correction of fixed kyphosis by bony union. Cervical pedicle screw fixation is the most advantageous instrumentation in the correction of cervical kyphosis.

Entities:  

Mesh:

Year:  1999        PMID: 10586466     DOI: 10.1097/00007632-199911150-00017

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  40 in total

1.  Three-column osteotomies of the lower cervical and upper thoracic spine: comparison of early outcomes, radiographic parameters, and peri-operative complications in 48 patients.

Authors:  Alexander A Theologis; Ehsan Tabaraee; Haruki Funao; Justin S Smith; Shane Burch; Bobby Tay; Khaled Kebaish; Vedat Deviren; Christopher Ames
Journal:  Eur Spine J       Date:  2014-11-14       Impact factor: 3.134

2.  Load sharing properties of cervical pedicle screw-rod constructs versus lateral mass screw-rod constructs.

Authors:  Bradley J Dunlap; Eldin E Karaikovic; Hyung-Soon Park; Mark J Sokolowski; Li-Qun Zhang
Journal:  Eur Spine J       Date:  2010-02-02       Impact factor: 3.134

3.  The stabilizing potential of anterior, posterior and combined techniques for the reconstruction of a 2-level cervical corpectomy model: biomechanical study and first results of ATPS prototyping.

Authors:  Heiko Koller; Rene Schmidt; Michael Mayer; Wolfgang Hitzl; Juliane Zenner; Stefan Midderhoff; Stefan Middendorf; Nicolaus Graf; Nicolaus Gräf; H Resch; Hans-Joachim Wilke; Hans-Joachim Willke
Journal:  Eur Spine J       Date:  2010-06-30       Impact factor: 3.134

Review 4.  [Instability of the upper cervical spine due to rheumatism].

Authors:  C E Heyde; U Weber; R Kayser
Journal:  Orthopade       Date:  2006-03       Impact factor: 1.087

5.  Cervical anterior transpedicular screw fixation. Part I: Study on morphological feasibility, indications, and technical prerequisites.

Authors:  Heiko Koller; Axel Hempfing; Frank Acosta; Michael Fox; Armin Scheiter; Mark Tauber; Ulrich Holz; Herbert Resch; Wolfgang Hitzl
Journal:  Eur Spine J       Date:  2008-01-26       Impact factor: 3.134

6.  Clinical accuracy of cervical pedicle screw insertion using lateral fluoroscopy: a radiographic analysis of the learning curve.

Authors:  Hisashi Yoshimoto; Shigenobu Sato; Takahiko Hyakumachi; Yasushi Yanagibashi; Taiki Kanno; Takeshi Masuda
Journal:  Eur Spine J       Date:  2009-08-04       Impact factor: 3.134

7.  Optimal entry points and trajectories for cervical pedicle screw placement into subaxial cervical vertebrae.

Authors:  Dong-Ho Lee; Sung-Woo Lee; Suk Jung Kang; Chang Ju Hwang; Nam Heun Kim; Ju-Yul Bae; Yung-Tae Kim; Choon Sung Lee; K Daniel Riew
Journal:  Eur Spine J       Date:  2011-04-09       Impact factor: 3.134

8.  Prevention of spinal cord injury using brain-evoked muscle-action potential (Br(E)-MsEP) monitoring in cervical spinal screw fixation.

Authors:  Kazuyoshi Kobayashi; Shiro Imagama; Zenya Ito; Kei Ando; Tetsuro Hida; Naoki Ishiguro
Journal:  Eur Spine J       Date:  2016-12-31       Impact factor: 3.134

9.  Preoperative imaging of cervical pedicles: comparison of accuracy of oblique radiographs versus axial CT scans.

Authors:  James P Sieradzki; Eldin E Karaikovic; Eugene P Lautenschlager; Martin L Lazarus
Journal:  Eur Spine J       Date:  2008-07-26       Impact factor: 3.134

Review 10.  [Therapy of cervical rheumatoid arthritis].

Authors:  R Kothe; L Wiesner; W Rüther
Journal:  Z Rheumatol       Date:  2004-08       Impact factor: 1.372

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.