Literature DB >> 10584953

Delayed rupture of the flexor pollicis longus tendon after inappropriate placement of the pi plate on the volar surface of the distal radius.

J A Nunley1, P R Rowan.   

Abstract

The pi plate (Synthes Ltd, Paoli, PA) was designed to fit the unique contour of the dorsal aspect of the distal radius. Complications of pi plate fixation of the dorsal distal radius have been previously reported to include both extensor tenosynovitis and delayed extensor tendon rupture. We report a case of rupture of the flexor pollicis longus tendon associated with inappropriate placement of the pi plate on the volar surface of the distal radius.

Entities:  

Mesh:

Year:  1999        PMID: 10584953     DOI: 10.1053/jhsu.1999.1279

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  20 in total

Review 1.  [Is routine implant removal after trauma surgery sensible?].

Authors:  C Krettek; C Müller; R Meller; M Jagodzinski; F Hildebrand; R Gaulke
Journal:  Unfallchirurg       Date:  2012-04       Impact factor: 1.000

2.  Dorsal tangential view of the wrist to detect screw penetration to the dorsal cortex of the distal radius after volar fixed-angle plating.

Authors:  Kagan Ozer; Serdar Toker
Journal:  Hand (N Y)       Date:  2011-01-07

Review 3.  Treatment of osteoporotic distal radius fractures.

Authors:  David Ring; Jesse B Jupiter
Journal:  Osteoporos Int       Date:  2004-12-22       Impact factor: 4.507

4.  Flexor tendon problems after volar plate fixation of distal radius fractures.

Authors:  Mehdi N Adham; Margaret Porembski; Christine Adham
Journal:  Hand (N Y)       Date:  2009-03-13

5.  Retrospective comparison of percutaneous fixation and volar internal fixation of distal radius fractures.

Authors:  Santiago A Lozano-Calderón; Job N Doornberg; David Ring
Journal:  Hand (N Y)       Date:  2007-09-18

6.  Radiographic evaluation of dorsal screw penetration after volar fixed-angle plating of the distal radius: a cadaveric study.

Authors:  Steven D Maschke; Peter J Evans; David Schub; Richard Drake; Jeffrey N Lawton
Journal:  Hand (N Y)       Date:  2007-04-26

7.  Rehabilitation of flexor tendon ruptures after volar plate fixation of the distal radius: a case series.

Authors:  Kristin Valdes
Journal:  Hand (N Y)       Date:  2011-09-07

8.  Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction.

Authors:  Re Anakwe; Lak Khan; Re Cook; Je McEachan
Journal:  J Orthop Surg Res       Date:  2010-08-05       Impact factor: 2.359

9.  Plate fixation of distal radius fracture and related complications.

Authors:  Laurent Obert; Francois Loisel; Sonia Huard; Séverin Rochet; Daniel Lepage; Gregoire Leclerc; Patrick Garbuio
Journal:  Eur J Orthop Surg Traumatol       Date:  2014-10-02

10.  Volar plate fixation of intra-articular distal radius fractures: a retrospective study.

Authors:  Margaret W M Fok; Melissa A Klausmeyer; Diego L Fernandez; Jorge L Orbay; Alex Lluch Bergada
Journal:  J Wrist Surg       Date:  2013-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.