Literature DB >> 20687926

Locked volar plating for complex distal radius fractures: Patient reported outcomes and satisfaction.

Re Anakwe1, Lak Khan, Re Cook, Je McEachan.   

Abstract

BACKGROUND: Distal radius fractures are common. The increasing prevalence of osteoporosis contributes to frequently complex articular injuries sustained even after low energy falls. The best method of treating complex type C distal radius fractures is debated. Locked volar plating and external fixation are both widely used with good reported results. Measures of success are traditionally based on technical measurements or the perception of the surgeon. Patient reported measures of outcome are increasingly recognised as important markers of surgical success. We report our experience using locked volar plating for complex type C distal radius fractures as well as patient reported measures of success and satisfaction.
METHODS: Over a 12 month period we treated 21 patients with type C distal radius fractures using locked volar plating. These patients were followed up for at least 12 months and the outcome was assessed using clinical examination, grip strength measurements, radiographs and Patient Rated Wrist Evaluation (PRWE) scoring.
RESULTS: The 21 patients studied had an average age of 48 years. There were 8 men and 13 women. All of the fractures had united by 3 months. There were no cases of wound infection or tendon injury/irritation. Patients reported low pain scores, good patient rated wrist evaluation scores and high levels of satisfaction.
CONCLUSIONS: Locked volar plating for complex distal radius fractures produces good results when assessed using patient reported measures of outcome. Further work should address whether locked volar plating offers superior outcomes and patient satisfaction compared to external fixation.

Entities:  

Year:  2010        PMID: 20687926      PMCID: PMC2924300          DOI: 10.1186/1749-799X-5-51

Source DB:  PubMed          Journal:  J Orthop Surg Res        ISSN: 1749-799X            Impact factor:   2.359


  24 in total

Review 1.  Volar plate fixation of distal radius fractures.

Authors:  Jorge Orbay
Journal:  Hand Clin       Date:  2005-08       Impact factor: 1.907

Review 2.  Development of a scale for patient rating of wrist pain and disability.

Authors:  J C MacDermid
Journal:  J Hand Ther       Date:  1996 Apr-Jun       Impact factor: 1.950

3.  Grip strength and forearm circumference in a healthy population.

Authors:  R E Anakwe; J S Huntley; J E McEachan
Journal:  J Hand Surg Eur Vol       Date:  2007-01-02

4.  Comparison of locked volar plating versus pinning and external fixation in the treatment of unstable intraarticular distal radius fractures.

Authors:  Marco Rizzo; Brian A Katt; Joshua T Carothers
Journal:  Hand (N Y)       Date:  2007-10-17

5.  Patient rating of wrist pain and disability: a reliable and valid measurement tool.

Authors:  J C MacDermid; T Turgeon; R S Richards; M Beadle; J H Roth
Journal:  J Orthop Trauma       Date:  1998 Nov-Dec       Impact factor: 2.512

6.  Comparison of external and percutaneous pin fixation with plate fixation for intra-articular distal radial fractures. A randomized study.

Authors:  Frankie Leung; Yuan-Kun Tu; Winston Y C Chew; Shew-Ping Chow
Journal:  J Bone Joint Surg Am       Date:  2008-01       Impact factor: 5.284

Review 7.  Outcome evaluation measures for wrist and hand: which one to choose?

Authors:  Manish Changulani; Ugochuku Okonkwo; Tulsi Keswani; Yegappan Kalairajah
Journal:  Int Orthop       Date:  2007-05-30       Impact factor: 3.075

Review 8.  What counts: outcome assessment after distal radius fractures in aged patients.

Authors:  Jörg Goldhahn; Felix Angst; Beat R Simmen
Journal:  J Orthop Trauma       Date:  2008-09       Impact factor: 2.512

9.  Bridging external fixation and supplementary Kirschner-wire fixation versus volar locked plating for unstable fractures of the distal radius: a randomised, prospective trial.

Authors:  K Egol; M Walsh; N Tejwani; T McLaurin; C Wynn; N Paksima
Journal:  J Bone Joint Surg Br       Date:  2008-09

10.  Patient-reported outcome and quality of life instruments database (PROQOLID): frequently asked questions.

Authors:  Marie-Pierre Emery; Laure-Lou Perrier; Catherine Acquadro
Journal:  Health Qual Life Outcomes       Date:  2005-03-08       Impact factor: 3.186

View more
  3 in total

1.  Unstable Distal Radius Fractures Treated by Volar Locking Anatomical Plates.

Authors:  Anto Jose; Shishir Murugharaj Suranigi; Pascal Noel Deniese; Abey Thomas Babu; Kanagasabai Rengasamy; Syed Najimudeen
Journal:  J Clin Diagn Res       Date:  2017-01-01

2.  A Review of Surgically Treated Distal Radius Fractures in a University Hospital.

Authors:  A S Bahar-Moni; S K Wong; N Mohd-Shariff; J Sapuan; S Abdullah
Journal:  Malays Orthop J       Date:  2021-11

3.  STATISTICAL ANALYSIS ON FUNCTIONAL AND RADIOGRAPHIC RESULTS AFTER USE OF LOCKED VOLAR PLATE FOR FRACTURES OF THE DISTAL RADIUS.

Authors:  Daniel Gonçalves Machado; Sergio Auto da Cruz Cerqueira; Rodrigo Ribeiro Pinho Rodarte; Carlos Alberto de Souza Araújo Netto; Marcelo Bezerra de Mathias
Journal:  Rev Bras Ortop       Date:  2015-12-06
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.