Literature DB >> 9027238

Mechanism of peptide separations by solid phase extraction capillary electrophoresis at low pH.

M A Strausbauch1, J P Landers, P J Wettstein.   

Abstract

A device for on-line extraction and concentration of peptides from a dilute sample matrix prior to direct capillary electrophoretic analysis is described. The technique, termed solid phase extraction capillary electrophoresis (SPE-CE), can facilitate analysis of peptides in the low nanograms per milliliter range. Peptides from a sample matrix are adsorbed on a reversed phase resin (C-8 or C-18) cartridge in-line with an uncoated fused-silica capillary and subsequently released for free zone electrophoresis by injection of an organic elutant. Unlike previous designs and commercially available packed-inlet capillaries, the device is easily constructed from common laboratory materials and is applicable to a wide range of conventional instrumentation and methods. This device and method has been developed for use in our laboratory as a stand-alone preparative technique, specifically to provide a second-dimensional orthogonal separation of biologically derived HPLC fractions of peptides in a single analysis. To this end, extensive effort was required in both device construction and method development to attain the successful separations which are reported in this study. Extractions of dilute peptide mixtures from sample injections exceeding, but not limited to, 20 times (48 microL) the capillary volume with apparent recovery greater than 80% are shown. The selectivity of extraction of individual components of a very dilute peptide mixture (31 ng/mL with 280 microL of sample injected) is presented. The ability to efficiently extract the individual peptides from the sample was found to be concentration-dependent for the individual peptide components over a 1600-field dilution of a common calibration mixture of nine model peptides. Varying the injected volume of elution buffer demonstrated the importance of minimizing the amount of buffer used to desorb peptides to maximize the resolution of individual peptides. This study highlights implementation for direct SPE-CE for peptide analysis and discusses for SPE tip-induced mechanism through which reversal in electoosmotic flow occurs.

Entities:  

Mesh:

Substances:

Year:  1996        PMID: 9027238     DOI: 10.1021/ac9503217

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  7 in total

1.  Sheathless preconcentration-capillary zone electrophoresis-mass spectrometry applied to peptide analysis.

Authors:  M B Barroso; A P de Jong
Journal:  J Am Soc Mass Spectrom       Date:  1999-12       Impact factor: 3.109

2.  On-column sample preconcentration using sample matrix switching and field amplification for increased sensitivity of capillary electrophoretic analysis of physiological samples.

Authors:  Y Zhao; K McLaughlin; C E Lunte
Journal:  Anal Chem       Date:  1998-11-01       Impact factor: 6.986

Review 3.  Capillary electrophoresis in pharmaceutical analysis.

Authors:  L A Holland; N P Chetwyn; M D Perkins; S M Lunte
Journal:  Pharm Res       Date:  1997-04       Impact factor: 4.200

4.  On-line sample preconcentration using field-amplified stacking injection in microchip capillary electrophoresis.

Authors:  Maojun Gong; Kenneth R Wehmeyer; Patrick A Limbach; Francisco Arias; William R Heineman
Journal:  Anal Chem       Date:  2006-06-01       Impact factor: 6.986

5.  H4 and CTT-2 minor histocompatibility antigens: concordant genetic linkage and migration in two-dimensional peptide separation.

Authors:  W K Nevala; P J Wettstein
Journal:  Immunogenetics       Date:  1996       Impact factor: 2.846

6.  Improving the comprehensiveness and sensitivity of sheathless capillary electrophoresis-tandem mass spectrometry for proteomic analysis.

Authors:  Yueju Wang; Bryan R Fonslow; Catherine C L Wong; Aleksey Nakorchevsky; John R Yates
Journal:  Anal Chem       Date:  2012-10-05       Impact factor: 6.986

7.  Improving MCE with electrochemical detection using a bubble cell and sample stacking techniques.

Authors:  Qian Guan; Charles S Henry
Journal:  Electrophoresis       Date:  2009-10       Impact factor: 3.535

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.