Literature DB >> 10555814

Dosimetry of blood irradiation with radiochromic film.

M J Butson1, P K Yu, T Cheung, M G Carolan, K Y Quach, A Arnold, P E Metcalfe.   

Abstract

It has been shown that radiochromic film is an ideal dosimeter for assessment and verification of delivered dose to irradiated blood products. Using a parallel opposing two-field technique on a medical linear accelerator, blood is irradiated to diminish the risk of transfusion-associated graft vs. host disease (TA-GVHD). The blood products are irradiated in a Perspex blood box to an applied dose of 29.5-31.7 Gy. Verification of applied dose has been performed with thimble ionization chambers and radiochromic film. Radiochromic film results have matched absorbed dose measurements from ionization chambers at all sites within the 'active' treatment volume within +/-6% for a 95% confidence limit. Using a sample of 100 in-vitro measurements, radiochromic film has measured the average applied dose to blood products to be 30.95+/-2.6 Gy for two standard deviations. Like currently available 'irradiated' film labels, the radiochromic film also serves as a visible reminder that the blood products have been irradiated.

Entities:  

Mesh:

Year:  1999        PMID: 10555814     DOI: 10.1046/j.1365-3148.1999.00200.x

Source DB:  PubMed          Journal:  Transfus Med        ISSN: 0958-7578            Impact factor:   2.019


  4 in total

1.  Radiation dose verification of an X-ray based blood irradiator using EBT3 radiochromic films calibrated using Gamma Knife machine.

Authors:  Khaled Soliman; Marouf Adili; Abdullah Alrushoud
Journal:  Rep Pract Oncol Radiother       Date:  2019-06-07

2.  Implementation of a new cost efficacy method for blood irradiation using a non dedicated device.

Authors:  Paola Pinnarò; Antonella Soriani; Daniela D'Alessio; Carolina Giordano; Maria Laura Foddai; Valentina Pinzi; Lidia Strigari
Journal:  J Exp Clin Cancer Res       Date:  2011-01-12

3.  Diacetylene-Based Colorimetric Radiation Sensors for the Detection and Measurement of γ Radiation during Blood Irradiation.

Authors:  Apoorva Mittal; Shalini Verma; Gopishankar Natanasabapathi; Pratik Kumar; Akhilesh K Verma
Journal:  ACS Omega       Date:  2021-03-29

4.  Prevention of transfusion-associated graft-versus-host disease by irradiation: technical aspect of a new ferrous sulphate dosimetric system.

Authors:  Lucas Sacchini Del Lama; Evamberto Garcia de Góes; Paulo César Dias Petchevist; Edson Lara Moretto; José Carlos Borges; Dimas Tadeu Covas; Adelaide de Almeida
Journal:  PLoS One       Date:  2013-06-07       Impact factor: 3.240

  4 in total