The roles of multileaf collimators and micro-multileaf collimators in conformal and conventional nasopharyngeal carcinoma radiotherapy treatments.

K Y Cheung1, P H Choi, R M Chau, L K Lee, P M Teo, Y K Ngar.   

Abstract

The purpose of this work is to study the efficacy and limitations of using standard multileaf collimators (MLCs) and micro-multileaf collimators (mMLCs) in the treatment of nasopharyngeal carcinoma (NPC) by conventional and conformal radiotherapy techniques. The penumbra characteristics of MLC, mMLC, and customized block collimated beams are measured with respect to leaf edge angle, beam energy, treatment depth, and field size and compared with those generated by a commercial three-dimensional planning computer system. Upon verification of the planning system, it is used to evaluate the treatment plans generated with these beam shapers for conventional and conformal NPC treatments. The effective penumbra of a MLC beam is strongly influenced by its edge angle, leaf width, and treatment depth. The suitability of standard MLCs in conventional NPC treatments is determined mainly by the edge angle to be used. For conformal NPC treatments involving six or more fields, dose volume histograms comparable to those of customized beam blocks are obtained with a standard MLC. The mMLC does not have the same restrictions as those on standard MLC but is limited to phase II treatment by its small usable field size. Both standard MLCs and mMLCs can be used to replace customized divergent beam blocks in both conventional and conformal NPC treatments. However, a MLC, due to its larger effective penumbra, may be unsuitable for use in cases when the tumor volumes extend very close to the critical normal structures. A mMLC, on the other hand, is limited by its small maximum field size and can only be used for collimating the facial portals in the second phase treatment.

Entities:  

Mesh:

Year:  1999        PMID: 10535623     DOI: 10.1118/1.598722

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Implications of a high-definition multileaf collimator (HD-MLC) on treatment planning techniques for stereotactic body radiation therapy (SBRT): a planning study.

Authors:  James A Tanyi; Paige A Summers; Charles L McCracken; Yiyi Chen; Li-Chung Ku; Martin Fuss
Journal:  Radiat Oncol       Date:  2009-07-10       Impact factor: 3.481

2.  Dosimetric comparison using different multileaf collimeters in intensity-modulated radiotherapy for upper thoracic esophageal cancer.

Authors:  Youling Gong; Shichao Wang; Lin Zhou; Yongmei Liu; Yong Xu; You Lu; Sen Bai; Yuchuan Fu; Qingfeng Xu; Qingfeng Jiang
Journal:  Radiat Oncol       Date:  2010-07-15       Impact factor: 3.481

3.  Dosimetric characteristics of dual-layer multileaf collimation for small-field and intensity-modulated radiation therapy applications.

Authors:  Yaxi Liu; Chengyu Shi; Patricia Tynan; Niko Papanikolaou
Journal:  J Appl Clin Med Phys       Date:  2008-03-31       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.