Literature DB >> 10525816

Hepatic CT enhancement: effect of the rate and volume of contrast medium injection in an animal model.

P Garcia1, G Genin, P M Bret, V M Bonaldi, C Reinhold, M Atri.   

Abstract

BACKGROUND: To evaluate the relative effect of rate of injection and volume of contrast medium on aortic, portal, and hepatic enhancement during computed tomography (CT).
METHODS: Thirty-eight nonincremental CT examinations were performed in three mini-pigs by using a combination of three different volumes (1.5, 2, and 3 mL/kg) and five different rates (1.5, 3, 4.5, 6, and 7.5 mL/s) of contrast material injection. Time-density enhancement curves of the aorta, portal vein, and liver were plotted over time for each rate of injection, each volume of contrast, and each volume-rate combination. In addition, aortic, portal, and liver peak enhancements, time-to-peak enhancements, optimal scanning intervals, and contrast enhancement indices were calculated for each volume-rate combination.
RESULTS: Higher rates of injection increased peak aortic enhancement but had no effect on peak portal or hepatic enhancement. This result may be explained by the dilution of the bolus of contrast medium in the splanchnic circulation. When the results of a 6-mL/s injection of 1.5 mL/kg of contrast material were compared with a 3-mL/s injection of 2 mL/kg, maximum aortic enhancement increased by 32%, whereas maximum liver enhancement decreased by 35%.
CONCLUSION: An increase in the rate of contrast injection results in an increase of peak aortic enhancement even when the total iodine load is decreased. However, an increase of the rate of contrast injection does not increase maximum liver enhancement, which is related to the total iodine dose injected. Therefore, one cannot compensate a decrease in the iodine load by an increase in injection rate in contrast-enhanced CT of the liver.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10525816     DOI: 10.1007/s002619900572

Source DB:  PubMed          Journal:  Abdom Imaging        ISSN: 0942-8925


  9 in total

1.  Non-invasive 16-row multislice CT coronary angiography: usefulness of saline chaser.

Authors:  Filippo Cademartiri; Nico Mollet; Aad van der Lugt; Koen Nieman; Peter M T Pattynama; Pim J de Feyter; Gabriel P Krestin
Journal:  Eur Radiol       Date:  2003-12-19       Impact factor: 5.315

2.  Contrast material injection protocol with the flow rate adjusted to the heart rate for dual source CT coronary angiography.

Authors:  Xiaomei Zhu; Wenping Chen; Mei Li; Yi Xu; Hai Xu; Yinsu Zhu; Dehang Wang; Lijun Tang
Journal:  Int J Cardiovasc Imaging       Date:  2011-10-04       Impact factor: 2.357

3.  Compact-bolus dynamic CT protocol with a test bolus technique in 64-MDCT coronary angiography: comparison of fixed injection rate and duration protocol.

Authors:  Masafumi Kidoh; Takeshi Nakaura; Kazuo Awai; Daisuke Utsunomiya; Naritsugu Sakaino; Kazunori Harada; Shouzaburou Uemura; Yasuyuki Yamashita
Journal:  Jpn J Radiol       Date:  2012-11-30       Impact factor: 2.374

4.  Contrast-to-Noise Ratio Optimization in Coronary Computed Tomography Angiography: Validation in a Swine Model.

Authors:  Logan Hubbard; Shant Malkasian; Yixiao Zhao; Pablo Abbona; Sabee Molloi
Journal:  Acad Radiol       Date:  2018-08-30       Impact factor: 3.173

5.  Comparative Evaluation of Two Venous Sampling Techniques for the Assessment of Pancreatic Insulin and Zinc Release upon Glucose Challenge.

Authors:  Anil Kumar Pillai; William Silvers; Preston Christensen; Matthew Riegel; Beverley Adams-Huet; Ildiko Lingvay; Xiankai Sun; Orhan K Öz
Journal:  J Diabetes Res       Date:  2015-07-27       Impact factor: 4.011

6.  Timing optimization of low-dose first-pass analysis dynamic CT myocardial perfusion measurement: validation in a swine model.

Authors:  Logan Hubbard; Shant Malkasian; Yixiao Zhao; Pablo Abbona; Sabee Molloi
Journal:  Eur Radiol Exp       Date:  2019-04-03

7.  Contrast timing optimization of a two-volume dynamic CT pulmonary perfusion technique.

Authors:  Yixiao Zhao; Logan Hubbard; Shant Malkasian; Pablo Abbona; Sabee Molloi
Journal:  Sci Rep       Date:  2022-05-17       Impact factor: 4.379

8.  The impact of warmed intravenous contrast material on the bolus geometry of coronary CT angiography applications.

Authors:  Tuncay Hazirolan; Baris Turkbey; Erhan Akpinar; Murat Canyigit; Musturay Karcaaltincaba; Bora Peynircioglu; Z Dicle Balkanci; Deniz Akata; Ferhun Balkanci
Journal:  Korean J Radiol       Date:  2009-03-03       Impact factor: 3.500

9.  128-slice acceletated-pitch dual energy CT angiography of the head and neck: comparison of different low contrast medium volumes.

Authors:  Yu Chen; Huadan Xue; Zheng-yu Jin; Jie Zhang; Hao Sun; Xuan Wang; Zhu-hua Zhang; Da-ming Zhang; Guang-ming Lu; Zhao-qi Zhang; U Joseph Schoepf; Andreas M Bucher; Christopher D Wolla; Yun Wang
Journal:  PLoS One       Date:  2013-11-19       Impact factor: 3.240

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.