Literature DB >> 10525238

Short- and long-term histopathologic evaluation of stenting using a self-expanding nitinol stent in pig carotid and iliac arteries.

S Verheye1, M Y Salame, K A Robinson, M J Post, J P Carrozza, D S Baim, U Sigwart, S B King, N A Chronos.   

Abstract

Stenting is increasingly being used to treat carotid artery disease. However, complications including distal embolization, stent thrombosis, stent collapse from external compression, the need for high-pressure inflation with increased neointimal response, or balloon rupture during stent expansion and stent loss are all potential problems and of concern. To address each of these specific concerns, a new stent was designed, which is self-expandable, made of nitinol, with temperature-dependent superelastic properties, and with high vessel wall surface coverage. Since this device has a number of novel characteristics, we aimed to assess the short- and long-term histopathologic response in pig carotid and iliac arteries. Single stents were deployed in pig carotid and iliac arteries after overstretch balloon injury. Angiograms were performed pre- and poststenting and prior to sacrifice. Intravascular ultrasound was used before implantation to determine vessel size. Vessels were examined histologically at 1 month (n = 6) and 6 months (n = 6) for morphometric analysis, hemorrhage and thrombus, endothelialization, and inflammatory and fibrotic responses. There was a 100% angiographic success rate at implantation. In one case, it was determined histologically that a single stent was implanted in a dissection plane of a pig's left iliac artery and was occluded by organized thrombus, with the true lumen being patent. At 6-month follow-up, this was the only evidence of a single stent occlusion, with flow adjacent to the stent in the true lumen. In the other vessels, the stents showed good vessel wall-stent apposition and the lumens were patent with a concentric and thin neointima. Inflammatory cells were rare and there were no mural thrombi. Coverage of the vessel wall by endothelial-like cells was complete at 1 month. The novel nitinol EndoStent appears to have favorable biocompatibility with minimal thrombus deposition or inflammatory response, and its use is feasible for clinical application in carotid and iliac arteries. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10525238     DOI: 10.1002/(sici)1522-726x(199911)48:3<316::aid-ccd19>3.0.co;2-w

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  7 in total

Review 1.  New developments in endovascular interventions for extracranial carotid stenosis.

Authors:  W A Tan; C R Jarmolowski; L R Wechsler; M H Wholey
Journal:  Tex Heart Inst J       Date:  2000

Review 2.  Coronary stents: in these days of climate change should all stents wear coats?

Authors:  R Lowe; I B A Menown; G Nogareda; I M Penn
Journal:  Heart       Date:  2005-06       Impact factor: 5.994

3.  Nitinol Carbofilm coated stents for peripheral applications: study in the porcine model.

Authors:  M Prunotto; C Isaia; M A Gatti; E Monari; E Pasquino; M Galloni
Journal:  J Mater Sci Mater Med       Date:  2005-12       Impact factor: 3.896

4.  A novel model of accelerated intimal hyperplasia in the pig iliac artery.

Authors:  Rabih Houbballah; Alessandro Robaldo; Hassan Albadawi; James Titus; Glenn M LaMuraglia
Journal:  Int J Exp Pathol       Date:  2011-11-03       Impact factor: 1.925

5.  Carotid artery stenting using a novel self-expanding braided nickel-titanium stent: feasibility and safety porcine trial.

Authors:  Frank Ahlhelm; Ralf Kaufmann; Dirk Ahlhelm; Mai Fang Ong; Christian Roth; Wolfgang Reith
Journal:  Cardiovasc Intervent Radiol       Date:  2009-06-16       Impact factor: 2.740

6.  Increased artery wall stress post-stenting leads to greater intimal thickening.

Authors:  Lucas H Timmins; Matthew W Miller; Fred J Clubb; James E Moore
Journal:  Lab Invest       Date:  2011-03-28       Impact factor: 5.662

7.  Self-expandable nitinol stent placement in homocysteinemic porcine aorta.

Authors:  Luís Henrique Gil França; Adamastor Humberto Pereira; Sílvio César Perini
Journal:  Clinics (Sao Paulo)       Date:  2008-04       Impact factor: 2.365

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.