Literature DB >> 10517150

Multiple-analyte fluoroimmunoassay using an integrated optical waveguide sensor.

T E Plowman1, J D Durstchi, H K Wang, D A Christensen, J N Herron, W M Reichert.   

Abstract

A silicon oxynitride integrated optical waveguide was used to evanescently excite fluorescence from a multianalyte sensor surface in a rapid, sandwich immunoassay format. Multiple analyte immunoassay (MAIA) results for two sets of three different analytes, one employing polyclonal and the other monoclonal capture antibodies, were compared with results for identical analytes performed in a single-analyte immunoassay (SAIA) format. The MAIA protocol was applied in both phosphate-buffered saline and simulated serum solutions. Point-to-point correlation values between the MAIA and SAIA results varied widely for the polyclonal antibodies (R2 = 0.42-0.98) and were acceptable for the monoclonal antibodies (R2 = 0.93-0.99). Differences in calculated receptor affinities were also evident with polyclonal antibodies, but not so with monoclonal antibodies. Polyclonal antibody capture layers tended to demonstrate departure from ideal receptor-ligand binding while monoclonal antibodies generally displayed monovalent binding. A third set of three antibodies, specific for three cardiac proteins routinely used to categorize myocardial infarction, were also evaluated with the two assay protocols. MAIA responses, over clinically significant ranges for creatin kinase MB, cardiac troponin I, and myoglobin agreed well with responses generated with SAIA protocols (R2 = 0.97-0.99).

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10517150     DOI: 10.1021/ac990183b

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  10 in total

1.  Virus detection using filament-coupled antibodies.

Authors:  Gregory P Stone; Ray Mernaugh; Frederick R Haselton
Journal:  Biotechnol Bioeng       Date:  2005-09-20       Impact factor: 4.530

2.  Adaptive virus detection using filament-coupled antibodies.

Authors:  Gregory P Stone; Kelvin S Lin; Frederick R Haselton
Journal:  J Biomed Opt       Date:  2006 May-Jun       Impact factor: 3.170

3.  Rapid multiplexed immunoassay for simultaneous serodiagnosis of HIV-1 and coinfections.

Authors:  Michael J Lochhead; Kathryn Todorof; Marie Delaney; Jeffrey T Ives; Charles Greef; Kevin Moll; Keagan Rowley; Kurt Vogel; Chris Myatt; Xing-Quan Zhang; Cathy Logan; Constance Benson; Sharon Reed; Robert T Schooley
Journal:  J Clin Microbiol       Date:  2011-08-24       Impact factor: 5.948

4.  Fabrication of a cyclic olefin copolymer planar waveguide embedded in a multi-channel poly(methyl methacrylate) fluidic chip for evanescence excitation.

Authors:  Paul I Okagbare; Jason M Emory; Proyag Datta; Jost Goettert; Steven A Soper
Journal:  Lab Chip       Date:  2009-11-04       Impact factor: 6.799

5.  Polymer microfluidic chips with integrated waveguides for reading microarrays.

Authors:  Feng Xu; Proyag Datta; Hong Wang; Sitanshu Gurung; Masahiko Hashimoto; Suying Wei; Jost Goettert; Robin L McCarley; Steven A Soper
Journal:  Anal Chem       Date:  2007-10-19       Impact factor: 6.986

6.  Thousand-fold fluorescent signal amplification for mHealth diagnostics.

Authors:  Joshua Balsam; Reuven Rasooly; Hugh Alan Bruck; Avraham Rasooly
Journal:  Biosens Bioelectron       Date:  2013-07-17       Impact factor: 10.618

7.  Capillary Array Waveguide Amplified Fluorescence Detector for mHealth.

Authors:  Joshua Balsam; Hugh Alan Bruck; Avraham Rasooly
Journal:  Sens Actuators B Chem       Date:  2013-09       Impact factor: 7.460

Review 8.  Physiologically based pharmacokinetic models: integration of in silico approaches with micro cell culture analogues.

Authors:  A Chen; M L Yarmush; T Maguire
Journal:  Curr Drug Metab       Date:  2012-07       Impact factor: 3.731

9.  Waveguide-based biosensors for pathogen detection.

Authors:  Harshini Mukundan; Aaron S Anderson; W Kevin Grace; Karen M Grace; Nile Hartman; Jennifer S Martinez; Basil I Swanson
Journal:  Sensors (Basel)       Date:  2009-07-21       Impact factor: 3.576

10.  Detection of cardiac biomarkers using single polyaniline nanowire-based conductometric biosensors.

Authors:  Innam Lee; Xiliang Luo; Jiyong Huang; Xinyan Tracy Cui; Minhee Yun
Journal:  Biosensors (Basel)       Date:  2012-05-14
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.