Literature DB >> 10511487

In-use barrier integrity of gloves: latex and nitrile superior to vinyl.

A Rego1, L Roley.   

Abstract

BACKGROUND: Although gloves manufactured with different materials have comparable barrier properties when removed directly from the box and tested, their actual on-the-job barrier performance may be extremely different. Although effective in static, pre-use conditions, barrier properties may be compromised once challenged by the rigorous hand and finger movements associated with many health care procedures. Gloves are meant to act as barriers, protecting persons by reducing the risk of exposure to bloodborne pathogens. Ineffective barriers or barriers that are easily breached during risk-associated procedures have the potential to place health care professionals at risk. Multiple studies attesting to the barrier attributes of vinyl and latex gloves during varied controlled clinical situations are available. Studies are available that address the permeation characteristics of nitrile, but no studies document the effectiveness of nitrile as a barrier to bloodborne pathogens or compare the barrier effectiveness of nitrile to gloves made of other materials during simulated use or clinical situations.
OBJECTIVE: This study was undertaken to compare the barrier integrity of latex, vinyl, and nitrile gloves during controlled, simulated clinical use conditions that were specifically designed to mimic patient care activities. This study compares the performance of gloves made of natural rubber latex, long considered the gold standard; polyvinyl chloride (vinyl), a synthetic copolymer; and nitrile (acrylonitrile butadiene), a recently available synthetic for use in the health care environment.
METHODS: A total of 2000 gloves (800 latex gloves, 800 vinyl gloves, and 400 nitrile gloves) were evaluated for baseline determinations in unused gloves and for failure rates after specific simulated use conditions. Potential bias was avoided through strict control of all actions and manipulations. Gloves were graded on a pass or fail system for leaks as defined by American Society for Testing and Materials D5151, Standard Test Method for Detection of Holes in Medical Gloves. To more fully characterize the gloves evaluated, individual products were also tested for physical dimensions (finger and palm thickness), powder levels, total protein (Modified Lowry), and antigenic protein (Latex ELISA [enzyme-linked immunosorbent assay] for Antigenic Proteins).
RESULTS: With the exception of one vinyl glove brand with a 12% failure rate, no significant differences in failure rates were detected among the 3 types of gloves when tested directly out of the box with no manipulation. However, after manipulation intended to simulate in-use conditions, vinyl gloves failed 12% to 61% of the time. Latex and nitrile performed significantly better, with failure rates of only 0% to 4% and 1% to 3%, respectively. All latex gloves, with one exception, tested at less than 50 microg/g of total water extractable protein. The antigenic protein levels, with one exception, tested from less than 0.2 microg/g to 5.5 microg/g. The one latex product that fell outside these values had 154 microg/g of total protein and 105.7 microg/g of antigenic protein.
CONCLUSIONS: This study indicates that the latex and nitrile gloves evaluated were comparable in terms of barrier performance characteristics both unused and during manipulations mimicking patient care procedures. Whereas stretch vinyl exhibited lower failure rates than standard vinyl, the higher in-use leakage rates associated with all vinyl gloves tested indicate decreased durability and, potentially, compromised barrier protection when this synthetic is used. Careful consideration to the degree of barrier effectiveness should be given before glove selection when the potential exposure to bloodborne pathogens or biohazard risks is a concern.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10511487     DOI: 10.1016/s0196-6553(99)70006-4

Source DB:  PubMed          Journal:  Am J Infect Control        ISSN: 0196-6553            Impact factor:   2.918


  16 in total

1.  Changes in chemical permeation of disposable latex, nitrile, and vinyl gloves exposed to simulated movement.

Authors:  Robert N Phalen; Thi Le; Weng Kee Wong
Journal:  J Occup Environ Hyg       Date:  2014       Impact factor: 2.155

2.  2007 Guideline for Isolation Precautions: Preventing Transmission of Infectious Agents in Health Care Settings.

Authors:  Jane D Siegel; Emily Rhinehart; Marguerite Jackson; Linda Chiarello
Journal:  Am J Infect Control       Date:  2007-12       Impact factor: 2.918

Review 3.  Biomaterials and Contraception: Promises and Pitfalls.

Authors:  Isabella Claure; Deborah Anderson; Catherine M Klapperich; Wendy Kuohung; Joyce Y Wong
Journal:  Ann Biomed Eng       Date:  2019-11-07       Impact factor: 3.934

4.  Tensile properties and integrity of clean room and low-modulus disposable nitrile gloves: a comparison of two dissimilar glove types.

Authors:  Robert N Phalen; Weng Kee Wong
Journal:  Ann Occup Hyg       Date:  2011-12-26

5.  Integrity of disposable nitrile exam gloves exposed to simulated movement.

Authors:  Robert N Phalen; Weng Kee Wong
Journal:  J Occup Environ Hyg       Date:  2011-05       Impact factor: 2.155

Review 6.  Evidence based management guidelines in dentistry during the COVID-19 pandemic - a review of the literature.

Authors:  Kanamarlapudi Venkata Saikiran; Putta Sai Sahiti; Somisetty Venkata Mahalakshmi Mounika; Sainath Reddy Elicherla; Raichurkar Hemanth Kumar; Gonegandla Giriraj Sandeep
Journal:  Med Pharm Rep       Date:  2021-10-30

Review 7.  [Individual prevention of occupational contact dermatitis: protective gloves and skin protection recommendations as part of the patient management scheme by the public statutory employers' liability insurance].

Authors:  A Wilke; C Skudlik; F K Sonsmann
Journal:  Hautarzt       Date:  2018-06       Impact factor: 0.751

8.  Human physiologic factors in respiratory uptake of 1,3-butadiene.

Authors:  Y S Lin; T J Smith; K T Kelsey; D Wypij
Journal:  Environ Health Perspect       Date:  2001-09       Impact factor: 9.031

Review 9.  Biosafety and Biosecurity in European Containment Level 3 Laboratories: Focus on French Recent Progress and Essential Requirements.

Authors:  Boris Pastorino; Xavier de Lamballerie; Rémi Charrel
Journal:  Front Public Health       Date:  2017-05-31

10.  The prevalence of latex sensitisation and allergy and associated risk factors among healthcare workers using hypoallergenic latex gloves at King Edward VIII Hospital, KwaZulu-Natal South Africa: a cross-sectional study.

Authors:  Shumani Makwarela Phaswana; Saloshni Naidoo
Journal:  BMJ Open       Date:  2013-12-09       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.