Literature DB >> 10502766

High-resolution three-dimensional in vivo imaging of atherosclerotic plaque.

G T Luk-Pat1, G E Gold, E W Olcott, B S Hu, D G Nishimura.   

Abstract

The internal structure of atherosclerotic-plaque lesions may be a useful predictor of which lesions will rupture and cause sudden events such as heart attack or stroke. With lipid and flow suppression, we obtained high-resolution, three-dimensional (3D) images of atherosclerotic plaque in vivo that show the cap thickness and core size of the lesions. 3D GRASE was used because it provides flexible T(2) contrast and good resistance to off-resonance artifacts. While 2D RARE has similar properties, its resolution in the slice-select direction, which is important because of the irregular geometry of atherosclerotic lesions, is limited by achievable slice-excitation profiles. Also, 2D imaging generally achieves lower SNR than 3D imaging because, for SNR purposes, 3D image data is averaged over all the slices of a corresponding multislice 2D dataset. Although 3D RARE has many of the advantages of 3D GRASE, it requires a longer scan time because it uses more refocusing pulses to acquire the same amount of data. Finally, cardiac gating is an important part of our imaging sequence, but can make the imaging time quite long. To obtain reasonable scan times, a 2D excitation pulse was used to restrict the field of view. Magn Reson Med 42:762-771, 1999. Copyright 1999 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  1999        PMID: 10502766     DOI: 10.1002/(sici)1522-2594(199910)42:4<762::aid-mrm19>3.0.co;2-m

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  22 in total

1.  Prospective self-gating for swallowing motion: a feasibility study in carotid artery wall MRI using three-dimensional variable-flip-angle turbo spin-echo.

Authors:  Zhaoyang Fan; Sven Zuehlsdorff; Xin Liu; Debiao Li
Journal:  Magn Reson Med       Date:  2011-12-09       Impact factor: 4.668

2.  Multi-contrast high spatial resolution black blood inner volume three-dimensional fast spin echo MR imaging in peripheral vein bypass grafts.

Authors:  Frank J Rybicki; Dimitrios Mitsouras; Christopher D Owens; Amanda Whitmore; Marie Gerhard-Herman; Nichole Wake; Tianxi Cai; Qian Zhou; Michael S Conte; Mark A Creager; Robert V Mulkern
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-24       Impact factor: 2.357

3.  Strategies for inner volume 3D fast spin echo magnetic resonance imaging using nonselective refocusing radio frequency pulses.

Authors:  Dimitris Mitsouras; Robert V Mulkern; Frank J Rybicki
Journal:  Med Phys       Date:  2006-01       Impact factor: 4.071

4.  CINE turbo spin echo imaging.

Authors:  Jason Mendes; Dennis L Parker; Jordan Hulet; Gerald S Treiman; Seong-Eun Kim
Journal:  Magn Reson Med       Date:  2011-06-23       Impact factor: 4.668

Review 5.  Imaging biomarkers of cardiovascular disease.

Authors:  Jinnan Wang; Niranjan Balu; Gador Canton; Chun Yuan
Journal:  J Magn Reson Imaging       Date:  2010-09       Impact factor: 4.813

6.  Dual stack black blood carotid artery CMR at 3T: application to wall thickness visualization.

Authors:  Axel Bornstedt; Mathias Burgmaier; Vinzenz Hombach; Nikolaus Marx; Volker Rasche
Journal:  J Cardiovasc Magn Reson       Date:  2009-11-10       Impact factor: 5.364

7.  Comparison between 2D and 3D high-resolution black-blood techniques for carotid artery wall imaging in clinically significant atherosclerosis.

Authors:  Niranjan Balu; Baocheng Chu; Thomas S Hatsukami; Chun Yuan; Vasily L Yarnykh
Journal:  J Magn Reson Imaging       Date:  2008-04       Impact factor: 4.813

8.  In vivo differentiation of two vessel wall layers in lower extremity peripheral vein bypass grafts: application of high-resolution inner-volume black blood 3D FSE.

Authors:  Dimitris Mitsouras; Christopher D Owens; Michael S Conte; Hale Ersoy; Mark A Creager; Frank J Rybicki; Robert V Mulkern
Journal:  Magn Reson Med       Date:  2009-09       Impact factor: 4.668

9.  Early animal model evaluation of an implantable contrast agent to enhance magnetic resonance imaging of arterial bypass vein grafts.

Authors:  Dimitrios Mitsouras; Ming Tao; Margreet R de Vries; Kaspar Trocha; Oscar R Miranda; Praveen Kumar Vemula; Kui Ding; Amir Imanzadeh; Frederick J Schoen; Jeffrey M Karp; C Keith Ozaki; Frank J Rybicki
Journal:  Acta Radiol       Date:  2018-01-29       Impact factor: 1.990

10.  Preparation and initial characterization of biodegradable particles containing gadolinium-DTPA contrast agent for enhanced MRI.

Authors:  Amber L Doiron; Kevin Chu; Adeel Ali; Lisa Brannon-Peppas
Journal:  Proc Natl Acad Sci U S A       Date:  2008-09-16       Impact factor: 11.205

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.