Literature DB >> 10477025

Initial clinical experience with a video-based patient positioning system.

L S Johnson1, B D Milliken, S W Hadley, C A Pelizzari, D J Haraf, G T Chen.   

Abstract

PURPOSE: To report initial clinical experience with an interactive, video-based patient positioning system that is inexpensive, quick, accurate, and easy to use. METHODS AND MATERIALS: System hardware includes two black-and-white CCD cameras, zoom lenses, and a PC equipped with a frame grabber. Custom software is used to acquire and archive video images, as well as to display real-time subtraction images revealing patient misalignment in multiple views. Two studies are described. In the first study, video is used to document the daily setup histories of 5 head and neck patients. Time-lapse cine loops are generated for each patient and used to diagnose and correct common setup errors. In the second study, 6 twice-daily (BID) head and neck patients are positioned according to the following protocol: at AM setups conventional treatment room lasers are used; at PM setups lasers are used initially and then video is used for 1-2 minutes to fine-tune the patient position. Lateral video images and lateral verification films are registered off-line to compare the distribution of setup errors per patient, with and without video assistance.
RESULTS: In the first study, video images were used to determine the accuracy of our conventional head and neck setup technique, i.e., alignment of lightcast marks and surface anatomy to treatment room lasers and the light field. For this initial cohort of patients, errors ranged from sigma = 5 to 7 mm and were patient-specific. Time-lapse cine loops of the images revealed sources of the error, and as a result, our localization techniques and immobilization device were modified to improve setup accuracy. After the improvements, conventional setup errors were reduced to sigma = 3 to 5 mm. In the second study, when a stereo pair of live subtraction images were introduced to perform daily "on-line" setup correction, errors were reduced to sigma = 1 to 3 mm. Results depended on patient health and cooperation and the length of time spent fine-tuning the position.
CONCLUSION: An interactive, video-based patient positioning system was shown to reduce setup errors to within 1 to 3 mm in head and neck patients, without a significant increase in overall treatment time or labor-intensive procedures. Unlike retrospective portal image analysis, use of two live-video images provides the therapists with immediate feedback and allows for true 3-D positioning and correction of out-of-plane rotation before radiation is delivered. With significant improvement in head and neck alignment and the elimination of setup errors greater than 3 to 5 mm, margins associated with treatment volumes potentially can be reduced, thereby decreasing normal tissue irradiation.

Entities:  

Mesh:

Year:  1999        PMID: 10477025     DOI: 10.1016/s0360-3016(99)00182-0

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  11 in total

1.  Clinical results of a pilot study on stereovision-guided stereotactic radiotherapy and intensity modulated radiotherapy.

Authors:  Shidong Li; Lawrence R Kleinberg; Daniele Rigamonti; Moody D Wharam; Abdul Rashid; Juan Jackson; David Djajaputra; Shenjen He; Tunisia Creasey; Theodore L DeWeese
Journal:  Technol Cancer Res Treat       Date:  2010-12

2.  A survey of image-guided radiation therapy use in the United States.

Authors:  Daniel R Simpson; Joshua D Lawson; Sameer K Nath; Brent S Rose; Arno J Mundt; Loren K Mell
Journal:  Cancer       Date:  2010-08-15       Impact factor: 6.860

3.  Target registration errors with surface imaging system in conformal radiotherapy for prostate cancer: study on 19 patients.

Authors:  S Bartoncini; C Fiandra; M G Ruo Redda; S Allis; F Munoz; U Ricardi
Journal:  Radiol Med       Date:  2012-05-14       Impact factor: 3.469

4.  Verification of quality parameters for portal images in radiotherapy.

Authors:  Csilla Pesznyák; István Polgár; Csaba Weisz; Réka Király; Pál Zaránd
Journal:  Radiol Oncol       Date:  2010-12-31       Impact factor: 2.991

5.  Efficacy of monitoring patient's position during neurosurgical procedures: introduction of real-time display and record.

Authors:  Mitsuhiro Hasegawa; Mohsen Nouri; Hironori Fujisawa; Yutaka Hayashi; Joji Inamasu; Yuichi Hirose; Junkoh Yamashita
Journal:  Neurol Med Chir (Tokyo)       Date:  2015-03-23       Impact factor: 1.742

6.  Comparison of surface matching and target matching for image-guided pelvic radiation therapy for both supine and prone patient positions.

Authors:  Hui Zhao; Brian Wang; Vikren Sarkar; Prema Rassiah-Szegedi; Y Jessica Huang; Martin Szegedi; Long Huang; Victor Gonzalez; Bill Salter
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

7.  Clinical usefulness of a newly developed body surface navigation and monitoring system in radiotherapy.

Authors:  Hitoshi Takagi; Yasunori Obata; Hidetoshi Kobayashi; Kazuyuki Takenaka; Yasujirou Hirose; Hajime Goto; Tomohiko Hattori
Journal:  J Appl Clin Med Phys       Date:  2011-02-02       Impact factor: 2.102

8.  Recent advances in image-guided radiotherapy for head and neck carcinoma.

Authors:  Sameer K Nath; Daniel R Simpson; Brent S Rose; Ajay P Sandhu
Journal:  J Oncol       Date:  2009-07-29       Impact factor: 4.375

9.  Reproducibility of patient setup by surface image registration system in conformal radiotherapy of prostate cancer.

Authors:  Marco Krengli; Simone Gaiano; Eleonora Mones; Andrea Ballarè; Debora Beldì; Cesare Bolchini; Gianfranco Loi
Journal:  Radiat Oncol       Date:  2009-02-22       Impact factor: 3.481

10.  Characteristics of a novel treatment system for linear accelerator-based stereotactic radiosurgery.

Authors:  Ning Wen; Haisen Li; Kwang Song; Karen Chin-Snyder; Yujiao Qin; Jinkoo Kim; Maria Bellon; Misbah Gulam; Stephen Gardner; Anthony Doemer; Suneetha Devpura; James Gordon; Indrin Chetty; Farzan Siddiqui; Munther Ajlouni; Robert Pompa; Zane Hammoud; Michael Simoff; Steven Kalkanis; Benjamin Movsas; M Salim Siddiqui
Journal:  J Appl Clin Med Phys       Date:  2015-07-08       Impact factor: 2.102

View more